Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 412(30): 8249-8267, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33009596

RESUMO

The establishment of a reference method for the determination of the allergen protein content in a processed food material has been explored. An analytical approach was developed to enable the comparability of food allergen measurement results expressed in a decision-relevant manner. A proof of concept is here presented, resulting in quantity values for the common measurand, namely 'mass of total allergen protein per mass of food'. The quantities are determined with SI traceability to enable the comparability of reported results. A method for the quantification of total milk protein content in an incurred baked food at a concentration level clinically relevant is presented. The strategy on how to obtain the final analytical result is outlined. Challenges associated with this method are discussed, in particular the optimal extraction of the marker proteins, the complete digestion and release of the peptides in an equimolar fashion, the use of conversion factors to translate the amount of measured proteins into total milk protein and the estimation of the uncertainty contributions as well as of the combined uncertainty of the final result. The implementation of such a reference method for the determination of the total allergen content in a processed food is an important step, which will provide comparable measurement data of relevance to risk assessors. Graphical abstract.


Assuntos
Alérgenos/análise , Análise de Alimentos/métodos , Proteínas do Leite/análise , Leite/química , Sequência de Aminoácidos , Animais , Calibragem , Cromatografia Líquida/métodos , Humanos , Limite de Detecção , Proteínas do Leite/química , Peptídeos/análise , Peptídeos/química , Estudo de Prova de Conceito , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Incerteza
2.
Food Chem ; 234: 144-154, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28551218

RESUMO

Many publications have highlighted that routine ELISA methods do not give rise to equivalent gluten content measurement results. In this study, we assess this variation between results and its likely impact on the enforcement of the EU gluten-free legislation. This study systematically examines the feasibility of harmonizing gluten ELISA assays by the introduction of: a common extraction procedure; a common calibrator, such as a pure gluten extract and an incurred matrix material. The comparability of measurements is limited by a weak correlation between kit results caused by differences in the selectivity of the methods. This lack of correlation produces bias that cannot be corrected by using reference materials alone. The use of a common calibrator reduced the between-assay variability to some extent, but variation due to differences in selectivity of the assays was unaffected. Consensus on robust markers and their conversion to "gluten content" are required.


Assuntos
Ensaio de Imunoadsorção Enzimática , Glutens/análise , Calibragem
3.
J Proteomics ; 147: 156-168, 2016 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-26994601

RESUMO

UNLABELLED: Accurate, reliable and sensitive detection methods for gluten are required to support current EU regulations. The enforcement of legislative levels requires that measurement results are comparable over time and between methods. This is not a trivial task for gluten which comprises a large number of protein targets. This paper describes a strategy for defining a set of specific analytical targets for wheat gluten. A comprehensive proteomic approach was applied by fractionating wheat gluten using RP-HPLC (reversed phase high performance liquid chromatography) followed by a multi-enzymatic digestion (LysC, trypsin and chymotrypsin) with subsequent mass spectrometric analysis. This approach identified 434 peptide sequences from gluten. Peptides were grouped based on two criteria: unique to a single gluten protein sequence; contained known immunogenic and toxic sequences in the context of coeliac disease. An LC-MS/MS method based on selected reaction monitoring (SRM) was developed on a triple quadrupole mass spectrometer for the specific detection of the target peptides. The SRM based screening approach was applied to gluten containing cereals (wheat, rye, barley and oats) and non-gluten containing flours (corn, soy and rice). A unique set of wheat gluten marker peptides were identified and are proposed as wheat specific markers. SIGNIFICANCE: The measurement of gluten in processed food products in support of regulatory limits is performed routinely. Mass spectrometry is emerging as a viable alternative to ELISA based methods. Here we outline a set of peptide markers that are representative of gluten and consider the end user's needs in protecting those with coeliac disease. The approach taken has been applied to wheat but can be easily extended to include other species potentially enabling the MS quantification of different gluten containing species from the identified markers.


Assuntos
Glutens/análise , Proteômica/métodos , Triticum/química , Biomarcadores/análise , Doença Celíaca/etiologia , Doença Celíaca/prevenção & controle , Cromatografia Líquida de Alta Pressão , Especificidade da Espécie , Espectrometria de Massas em Tandem
4.
Food Chem ; 127(2): 669-75, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-23140717

RESUMO

Milk allergens are common allergens occurring in foods, therefore raising concern in allergic consumers. Enzyme-linked immunosorbent assay (ELISA) is, to date, the method of choice for the detection of food allergens by the food industry although, the performance of ELISA might be compromised when severe food processing techniques are applied to allergen-containing foods. In this paper we investigated the influence of baking time on the detection of milk allergens by using commercial ELISA kits. Baked cookies were chosen as a model food system and experiments were set up to study the impact of spiking a matrix food either before, or after the baking process. Results revealed clear analytical differences between both spiking methods, which stress the importance of choosing appropriate spiking methodologies for method validation purposes. Finally, since the narrow dynamic range of quantification of ELISA implies that dilution of samples is required, the impact of sample dilution on the quantitative results was investigated. All parameters investigated were shown to impact milk allergen detection by means of ELISA.

5.
Food Chem ; 127(2): 834-41, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-23140743

RESUMO

Lupin and soya are members of the Leguminosae family which are recognised as some of the richest source of vegetable proteins. Lupin- and soya-containing products are available on the EU market and could cause severe adverse reactions in allergic individuals, even if consumed at low concentrations. In this context the development of methods for reliable detection of these allergens in food products is a useful tool for the surveillance of established legislation on food labelling within the EU. This work described the development of a duplex real-time PCR method allowing the simultaneous detection of traces of lupin and soya in processed food based on a specific TaqMan® probe designed on a mitochondrial tRNA-MET gene. A set of primers and probes was designed for the amplification of a 168 and 175bp fragment of lupin and soya mitochondrial DNA, respectively. The performance of the method was established using lupin and soya flours and cookies baked from lupin- and soya-containing dough (different concentrations and baking times). The PCR platform yielded consistent and repeatable results. The specificity of the system was tested with DNA from 28 plant species. The sensitivity of the method was suitable to detect allergenic ingredients in the low mg per kg range. Both lupin and soya at a level of 2.5mg per kg food matrix could be detected in cookies baked at 180°C for 10min. The method was successfully applied to bakery (e.g. bread) and vegetarian (e.g. non-meat sausages) food products that contain or may contain soya and/or lupin as ingredient or contaminant (according to the declaration on the product label).

6.
Anal Bioanal Chem ; 395(1): 127-37, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19475402

RESUMO

Peanut allergic reactions can result from the ingestion of even very small quantities of peanut and represent a severe threat to the health of sensitised individuals. The detection of peanut traces in food products is therefore of prime importance. Peanut traces which can be (unintentionally) present in food products have usually undergone one or more processing steps like roasting and baking. Therefore, methods designed to detect such traces have to be capable of detecting heat-treated peanuts. Commonly used methodologies designed to detect peanut traces in food products are enzyme-linked immunosorbent assays (ELISAs) that detect peanut-specific proteins, and polymerase-chain-reaction (PCR)-based methods targeting peanut-specific DNA. A comparative analysis of such methods was performed and the impact of heat treatment on peanut kernels as well as the impact on a peanut-containing food matrix are investigated. Our results show that heat treatments have a detrimental effect on the detection of peanut with either type of method and that both types of methods are affected in a similar manner.


Assuntos
Alérgenos/análise , Antígenos de Plantas/análise , Arachis/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Temperatura Alta , Reação em Cadeia da Polimerase/métodos , Contaminação de Alimentos/análise , Métodos
7.
Food Addit Contam ; 24(12): 1334-44, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17852393

RESUMO

Accidental exposure to hazelnut or peanut constitutes a real threat to the health of allergic consumers. Correct information regarding food product ingredients is of paramount importance for the consumer, thereby reducing exposure to food allergens. In this study, 569 cookies and chocolates on the European market were purchased. All products were analysed to determine peanut and hazelnut content, allowing a comparison of the analytical results with information provided on the product label. Compared to cookies, chocolates are more likely to contain undeclared allergens, while, in both food categories, hazelnut traces were detected at higher frequencies than peanut. The presence of a precautionary label was found to be related to a higher frequency of positive test results. The majority of chocolates carrying a precautionary label tested positive for hazelnut, whereas peanut traces were not be detected in 75% of the cookies carrying a precautionary label.


Assuntos
Arachis/química , Cacau/química , Corylus/química , Análise de Alimentos/métodos , Rotulagem de Alimentos/normas , Adulto , Alérgenos/análise , Criança , Ensaio de Imunoadsorção Enzimática/métodos , Europa (Continente) , Humanos , Hipersensibilidade a Noz/imunologia
8.
J AOAC Int ; 89(2): 462-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16640295

RESUMO

Results are reported for an interlaboratory validation study of 2 commercially available Iateral flow devices (dipstick tests) designed to detect peanut residues in food matrixes. The test samples used in this study were cookies containing peanuts at 7 different concentrations in the range of 0-30 mg peanuts/kg food matrix. The test samples with sufficient and proven homogeneity were prepared in our laboratory. The analyses of the samples (5 times per level by each laboratory) were performed by 18 laboratories worldwide which submitted a total of 1260 analytical results. One laboratory was found to be an outlier for one of the test kits. In general, both test kits performed well. However, some false-negative results were reported for all matrixes containing < 21 mg peanuts/kg cookie. It must be stressed that the test kits were challenged beyond their cut-off limits (> or = 5 mg/kg, depending on the food matrix). One test kit showed fewer false-negative results, but it led to some false-positive results for the blank materials. The sensitivity of the dipstick tests approaches that achieved with enzyme-linked immunosorbent assays.


Assuntos
Arachis/química , Proteínas Alimentares/análise , Ensaio de Imunoadsorção Enzimática , Análise de Alimentos , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes
9.
J Agric Food Chem ; 54(3): 853-9, 2006 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-16448194

RESUMO

The purpose of this study was to evaluate the correlation between the acrylamide (AA) content and the antioxidant activity (AOA) of self-prepared cookies. Cookies were baked in the laboratory under defined conditions following four different recipes. The parameters of investigation were the influence of the type and relative content of sugar (glucose and fructose) and the baking time on the AA content as well as AOA of the final products. Parameters depending on the recipe and baking conditions such as the moisture content, the total nitrogen concentration, and the color of the products were evaluated for all samples as well. To prove the transferability of the findings gained with model cookies to samples from industry, the same measurements were performed on seven different types/brands of cookies that were purchased in local markets. A direct correlation was found between the concentration of AA and the AOA. With increasing baking time, the moisture content of the cookies decreased. The latter parameter correlated well with the AA concentration and AOA. The use of fructose enhanced the concentration of AA and the AOA of the final products, when compared with the use of sucrose. However, a simple model for the prediction of acrylamide contents and the AOA of samples from the baking time, color, protein, or moisture content of the samples was not found.


Assuntos
Acrilamida/análise , Antioxidantes/análise , Culinária , Análise de Alimentos , Cor , Frutose/análise , Glucose/análise , Temperatura Alta , Nitrogênio/análise , Fatores de Tempo , Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...