1.
J Med Microbiol ; 55(Pt 12): 1707-1710, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17108275

RESUMO

A fatal case of nosocomial legionellosis in a low prevalence region (Calgary, Alberta, Canada) prompted investigation into the source of infection. Hospital water systems contaminated with Legionella pneumophila have been shown to pose a risk to compromised patients. Typing of an L. pneumophila serogroup 1 strain isolated from the patient using sequence-based typing (SBT) and amplified fragment length polymorphism (AFLP) analysis linked it to a persistent and widespread strain isolated from the hospital water system establishing a nosocomial mode of acquisition. Different SBT and AFLP patterns were determined for non-epidemiologically linked cases and isolates from different hospitals.


Assuntos
Infecção Hospitalar/etiologia , Legionella pneumophila/classificação , Legionelose/etiologia , Pneumonia Bacteriana/etiologia , Idoso , Proteínas de Bactérias/genética , Canadá/epidemiologia , Infecção Hospitalar/epidemiologia , DNA Bacteriano/genética , Evolução Fatal , Feminino , Humanos , Legionella pneumophila/genética , Legionella pneumophila/isolamento & purificação , Legionelose/epidemiologia , Metaloendopeptidases/genética , Dados de Sequência Molecular , Pneumonia Bacteriana/epidemiologia , Polimorfismo de Fragmento de Restrição , Porinas/genética , Fatores de Risco , Análise de Sequência de Proteína , Especificidade da Espécie , Microbiologia da Água , Abastecimento de Água/análise