Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Perinat Med ; 51(5): 634-640, 2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-36441559

RESUMO

OBJECTIVES: To compare short term variation (STV) and phase rectified signal averaging (PRSA) and their association with fetal outcome in early onset fetal growth restriction (FGR). METHODS: Data were used from a retrospective cohort study of women who were admitted for FGR and/or pre-eclampsia and who were delivered by pre-labor Cesarean section or had a fetal death before 32 weeks' gestation. Computerized cardiotocography (cCTG) registrations of the 5 days before delivery or fetal death were used for calculation of STV and PRSA. PRSA was expressed as the average acceleration capacity (AAC) and average deceleration capacity (ADC). FHR decelerations were classified visually as absent, 1-2 per hour or recurrent. Abnormality of STV and of PRSA was either analyzed as a single parameter or in combination with recurrent decelerations. Endpoints were defined as composite adverse condition at birth consisting of fetal death, low Apgar score, low umbilical pH, the need for resuscitation after birth and as major neonatal morbidity or neonatal death. RESULTS: Included were 367 pregnancies of which 20 resulted in fetal death. An abnormal cCTG with either recurrent decelerations and/or low STV or recurrent decelerations and/or low PRSA were similarly associated with composite adverse condition at birth (n=99), but neither with major neonatal morbidity. CONCLUSIONS: PRSA and STV have similar efficacy for measuring fetal heart rate variation in early onset FGR. An increased risk of a composite adverse condition at birth is indicated by a low value of either parameter and/or the presence of recurrent decelerations.


Assuntos
Cesárea , Retardo do Crescimento Fetal , Recém-Nascido , Gravidez , Humanos , Feminino , Retardo do Crescimento Fetal/diagnóstico , Estudos Retrospectivos , Cardiotocografia/métodos , Morte Fetal , Frequência Cardíaca Fetal/fisiologia
2.
Obstet Gynecol Clin North Am ; 48(2): 371-385, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33972072

RESUMO

Impaired fetal growth owing to placental insufficiency is a major contributor to adverse perinatal outcomes. No intervention is available that improves outcomes by changing the pathophysiologic process. Monitoring in early-onset fetal growth restriction (FGR) focuses on optimizing the timing of iatrogenic preterm delivery using cardiotocography and Doppler ultrasound. In late-onset FGR, identifying the fetus at risk for immediate hypoxia and who benefits from expedited delivery is challenging. It is likely that studies in the next decade will provide evidence how to best integrate different monitoring variables and other prognosticators in risk models that are aimed to optimize individual treatment strategies.


Assuntos
Retardo do Crescimento Fetal/diagnóstico por imagem , Retardo do Crescimento Fetal/terapia , Cardiotocografia/métodos , Parto Obstétrico/métodos , Feminino , Desenvolvimento Fetal , Retardo do Crescimento Fetal/etiologia , Feto/diagnóstico por imagem , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Insuficiência Placentária/diagnóstico por imagem , Gravidez , Nascimento Prematuro/etiologia , Cuidado Pré-Natal/métodos , Ultrassonografia Doppler/métodos , Ultrassonografia Pré-Natal/métodos , Artérias Umbilicais/diagnóstico por imagem
3.
Brain Stimul ; 13(5): 1467-1475, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32585355

RESUMO

BACKGROUND: Prefrontal abnormalities in schizophrenia have consistently emerged from resting state and cognitive neuroimaging studies. However, these correlative findings require causal verification via combined imaging/stimulation approaches. To date, no interleaved transcranial magnetic stimulation and functional magnetic resonance imaging study (TMS fMRI) has probed putative prefrontal cortex abnormalities in schizophrenia. OBJECTIVE: /Hypothesis: We hypothesized that subjects with schizophrenia would show significant hyperexcitability at the site of stimulation (BA9) and decreased interhemispheric functional connectivity. METHODS: We enrolled 19 unmedicated subjects with schizophrenia and 22 controls. All subjects underwent brain imaging using a 3T MRI scanner with a SENSE coil. They also underwent a single TMS fMRI session involving motor threshold (rMT) determination, structural imaging, and a parametric TMS fMRI protocol with 10 Hz triplet pulses at 0, 80, 100 and 120% rMT. Scanning involved a surface MR coil optimized for bilateral prefrontal cortex image acquisition. RESULTS: Of the original 41 enrolled subjects, 8 subjects with schizophrenia and 11 controls met full criteria for final data analyses. At equal TMS intensity, subjects with schizophrenia showed hyperexcitability in left BA9 (p = 0.0157; max z-score = 4.7) and neighboring BA46 (p = 0.019; max z-score = 4.47). Controls showed more contralateral functional connectivity between left BA9 and right BA9 through increased activation in right BA9 (p = 0.02; max z-score = 3.4). GM density in subjects with schizophrenia positively correlated with normalized prefrontal to motor cortex ratio of the corresponding distance from skull to cortex ratio (S-BA9/S-MC) (r = 0.83, p = 0.004). CONCLUSIONS: Subjects with schizophrenia showed hyperexcitability in left BA9 and impaired interhemispheric functional connectivity compared to controls. Interleaved TMS fMRI is a promising tool to investigate prefrontal dysfunction in schizophrenia.


Assuntos
Excitabilidade Cortical , Imageamento por Ressonância Magnética/métodos , Rede Nervosa/diagnóstico por imagem , Córtex Pré-Frontal/diagnóstico por imagem , Esquizofrenia/diagnóstico por imagem , Estimulação Magnética Transcraniana/métodos , Adulto , Mapeamento Encefálico/métodos , Excitabilidade Cortical/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Córtex Motor/diagnóstico por imagem , Córtex Motor/fisiologia , Rede Nervosa/fisiologia , Córtex Pré-Frontal/fisiologia , Esquizofrenia/fisiopatologia
4.
Artigo em Inglês | MEDLINE | ID: mdl-32021976

RESUMO

Around 1 % of pregnancies develop Hyperemesis Gravidarum (HG), causing high physical and psychological morbidity. Reports on HG recurrence rate in subsequent pregnancies vary widely. An accurate rate of recurrence is needed for informed reproductive decision making. Our objective is to systematically review and aggregate reported rates for HG subsequent to index pregnancies affected by HG. We searched databases from inception as per the protocol registered on PROSPERO. No language restrictions were applied. Inclusion was not restricted based on how HG was defined; reports of severe NVP were included where authors defined the condition as HG. We included descriptive epidemiological, case control and cohort study designs. Eligibility screening was performed in duplo. We extracted data on populations, study methods and outcomes of significance. A panel of patients reviewed the results and provided discussion and feedback. Quality was assessed with the JBI (2017) critical appraisal tool independently by two reviewers. We performed the searches on 1st November 2019. Our search yielded 4454 unique studies, of which five (n = 40,350 HG cases) matched eligibility criteria; One longitudinal and four population-based cohort studies from five countries. Follow-up ranged from 2 to 31 years. Definition of HG and data collection methods in all the studies created heterogeneity. Quality was low; studies lacked valid and reliable exposure, and/or follow-up was insufficient. Meta-analysis was not possible due to clinical and statistical heterogeneity. This systematic review found five heterogeneous studies reporting recurrence rates from 15 to 81%. Defining HG as hospital cases may have introduced detection bias and contribute to clinical heterogeneity. A prospective longitudinal cohort study using an internationally agreed definition of HG and outcomes meaningful to patients is required to establish the true recurrence rate of HG.

5.
J Perinat Med ; 47(4): 439-447, 2019 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-31005952

RESUMO

Background We developed an open-source software for the computerized analysis of antenatal fetal cardiotocography (CTG) without limitation of duration of the registration, enabling batch processing and adaptation to any digital storage system. Methods STVcalc was developed based on literature about the FetalCare system (Huntleigh Healthcare Ltd, Cardiff, UK). For comparison with FetalCare, we selected the CTGs of all women who delivered in 2011 a small-for-gestational-age (SGA) fetus between 24 and 31 weeks by cesarean section (CS) for fetal distress, or had fetal death, before labor onset. Results In 471 CTGs from 39 women, the agreement was 99% for a short-term variation (STV) cut-off of 2.6 ms below 29 weeks and 3.0 ms thereafter, and 95% for 3.5 and 4.0 ms, respectively. In 18 (4%) cases, the proportional difference in STV between FetalCare and STVcalc was more than 10%. Conclusion As only slight differences were observed between the proposed feature-rich application and the FetalCare system, it can be considered valuable for clinical practice and research purposes.


Assuntos
Cardiotocografia , Retardo do Crescimento Fetal , Software , Feminino , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...