Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 14(9): e0222452, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31513637

RESUMO

PURPOSE: A 32-channel parallel transmit (pTx) add-on for 7 Tesla whole-body imaging is presented. First results are shown for phantom and in-vivo imaging. METHODS: The add-on system consists of a large number of hardware components, including modulators, amplifiers, SAR supervision, peripheral devices, a control computer, and an integrated 32-channel transmit/receive body array. B1+ maps in a phantom as well as B1+ maps and structural images in large volunteers are acquired to demonstrate the functionality of the system. EM simulations are used to ensure safe operation. RESULTS: Good agreement between simulation and experiment is shown. Phantom and in-vivo acquisitions show a field of view of up to 50 cm in z-direction. Selective excitation with 100 kHz sampling rate is possible. The add-on system does not affect the quality of the original single-channel system. CONCLUSION: The presented 32-channel parallel transmit system shows promising performance for ultra-high field whole-body imaging.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído
2.
Eur Radiol ; 29(12): 6529-6538, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31201525

RESUMO

PURPOSE: To evaluate the technical feasibility of high-resolution USPIO-enhanced magnetic resonance imaging of pelvic lymph nodes (LNs) at ultrahigh magnetic field strength. MATERIALS AND METHODS: The ethics review board approved this study and written informed consent was obtained from all patients. Three patients with rectal cancer and three selected patients with (recurrent) prostate cancer were examined at 7-T 24-36 h after intravenous ferumoxtran-10 administration; rectal cancer patients also received a 3-T MRI. Pelvic LN imaging was performed using the TIAMO technique in combination with water-selective multi-GRE imaging and lipid-selective GRE imaging with a spatial resolution of 0.66 × 0.66 × 0.66mm3. T2*-weighted images of the water-selective imaging were computed from the multi-GRE images at TE = 0, 8, and 14 ms and used for the assessment of USPIO uptake. RESULTS: High-resolution 7-T MR gradient-echo imaging was obtained robustly in all patients without suffering from RF-related signal voids. USPIO signal decay in LNs was visualized using computed TE imaging at TE = 8 ms and an R2* map derived from water-selective imaging. Anatomically, LNs were identified on a combined reading of computed TE = 0 ms images from water-selective scans and images from lipid-selective scans. A range of 3-48 LNs without USPIO signal decay was found per patient. These LNs showed high signal intensity on computed TE = 8 and 14 ms imaging and low R2* (corresponding to high T2*) values on the R2* map. CONCLUSION: USPIO-enhanced MRI of the pelvis at 7-T is technically feasible and offers opportunities for detecting USPIO uptake in normal-sized LNs, due to its high intrinsic signal-to-noise ratio and spatial resolution. KEY POINTS: • USPIO-enhanced MRI at 7-T can indicate USPIO uptake in lymph nodes based on computed TE images. • Our method promises a high spatial resolution for pelvic lymph node imaging.


Assuntos
Meios de Contraste , Dextranos , Aumento da Imagem/métodos , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita , Idoso , Estudos de Viabilidade , Feminino , Humanos , Linfonodos/patologia , Metástase Linfática/patologia , Masculino , Pessoa de Meia-Idade , Pelve/patologia , Reprodutibilidade dos Testes
3.
Magn Reson Med ; 82(2): 796-810, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30924181

RESUMO

PURPOSE: A 16-channel receive (16Rx) radiofrequency (RF) array for 7T ultra-high field body MR imaging is presented. The coil is evaluated in conjunction with a 16-channel transmit/receive (16TxRx) coil and additionally with a 32-channel transmit/receive (32TxRx) remote body coil for RF transmit and serving as receive references. METHODS: The 16Rx array consists of 16 octagonal overlapping loops connected to custom-built detuning boards with preamplifiers. Performance metrics like noise correlation, g-factors, and signal-to-noise ratio gain were compared between 4 different RF coil configurations. In vivo body imaging was performed in volunteers using radiofrequency shimming, time interleaved acquisition of modes (TIAMO), and 2D spatially selective excitation using parallel transmit (pTx) in the spine. RESULTS: Lower g-factors were obtained when using the 16Rx coil in addition to the 16TxRx array coil configuration versus the 16TxRx array alone. Distinct signal-to-noise ratio gain using the 16Rx coil could be demonstrated in the spine region both for a comparison with the 16TxRx coil (>50% gain) in vivo and the 32TxRx coil (>240% gain) in a phantom. The 16Rx coil was successfully applied to improve anatomical imaging in the abdomen and 2D spatially selective excitation in the spine of volunteers. CONCLUSION: The novel 16-channel Rx-array as an add-on to multichannel TxRx RF coil configurations provides increased signal-to-noise ratio, lower g-factors, and thus improves 7T ultra-high field body MR imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Coluna Vertebral/diagnóstico por imagem , Adulto , Desenho de Equipamento , Humanos , Masculino , Imagens de Fantasmas
4.
Med Phys ; 45(7): 2978-2990, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29679498

RESUMO

PURPOSE: In this work, a combined body coil array with eight transmit/receive (Tx/Rx) meander elements and with 24 receive-only (Rx) loops (8Tx/32Rx) was developed and evaluated in comparison with an 8-channel transmit/receive body array (8Tx/Rx) based on meander elements serving as the reference standard. METHODS: Systematic evaluation of the RF array was performed on a body-sized phantom. Body imaging at 7T was performed in six volunteers in the body regions pelvis, abdomen, and heart. Coil characteristics such as signal-to-noise ratio, acceleration capability, g-factors, S-parameters, noise correlation, and B1+ maps were assessed. Safety was ensured by numerical simulations using a coil model validated by dosimetric field measurements. RESULTS: Meander elements and loops are intrinsically well decoupled with a maximum coupling value of -20.5 dB. Safe use of the 8Tx/32Rx array could be demonstrated. High gain in signal-to-noise ratio (33% in the subject's center) could be shown for the 8Tx/32Rx array compared to the 8Tx/Rx array. Improvement in acceleration capability in all investigations could be demonstrated. For example, the 8Tx/32Rx array provides lower g-factors in the right-left and anterior-posterior directions with R = 3 undersampling as compared to the 8Tx/Rx array using R = 2. Both arrays are very similar regarding their RF transmit performance. Excellent image quality in the investigated body regions could be achieved with the 8Tx/32Rx array. CONCLUSION: In this work, we show that a combination of eight meander elements and 24 loop receive elements is possible without impeding transmit performance. Improved SNR and g-factor performance compared to an RF array without these loops is demonstrated. Body MRI at 7T with the 8Tx/32Rx array could be accomplished in the heart, abdomen, and pelvis with excellent image quality.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Ondas de Rádio , Desenho de Equipamento , Segurança , Razão Sinal-Ruído
6.
Magn Reson Med ; 79(5): 2652-2664, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28994132

RESUMO

PURPOSE: Current methods for mitigation of transmit field B1+ inhomogeneities at ultrahigh field (UHF) MRI by multi-channel radiofrequency (RF) shimming rely on accurate B1+ mapping. This can be time consuming when many RF channels have to be mapped for in vivo body MRI, where the B1 maps should ideally be acquired within a single breath-hold. Therefore, a new B1+ mapping technique (B1TIAMO) is proposed. METHODS: The performance of this technique is validated against an established method (DREAM) in phantom measurements for a cylindrical head phantom with an 8-channel transmit/receive (Tx/Rx) array. Furthermore, measurements for a 32-channel Tx/Rx remote array are conducted in a large body phantom and the |B1+| map reliability is validated against simulations of the transmit RF field distribution. Finally, in vivo results of this new mapping technique for human abdomen are presented. RESULTS: For the head phantom (8-channel Tx/Rx coil), the single |B1+| comparison between B1 TIAMO, the direct DREAM measurements, and simulation data showed good agreement with 10-19% difference. For the large body phantom (32-channel Tx/Rx coil), B1TIAMO matched the RF field simulations well. CONCLUSION: The results demonstrate the potential to acquire 32 accurate single-channel B1+ maps for large field-of-view body imaging within only a single breath-hold of 16 s at 7T UHF MRI. Magn Reson Med 79:2652-2664, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Cabeça/diagnóstico por imagem , Humanos , Rim/diagnóstico por imagem , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Imagem Corporal Total
7.
Med Phys ; 44(12): 6195-6208, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28976586

RESUMO

PURPOSE: In this work, we present an 8-channel transceiver (Tx/Rx) 7-channel receive (Rx) radiofrequency (RF) coil setup for 7 T ultrahigh-field MR imaging of the shoulder. METHODS: A C-shaped 8-channel Tx/Rx coil was combined with an anatomically close-fitting 7-channel Rx-only coil. The safety and performance parameters of this coil setup were evaluated on the bench and in phantom experiments. The 7 T MR imaging performance of the shoulder RF coil setup was evaluated in in vivo measurements using a 3D DESS, a 2D PD-weighted TSE sequence, and safety supervision based on virtual observation points. RESULTS: Distinct SNR gain and acceleration capabilities provided by the additional 7-channel Rx-only coil were demonstrated in phantom and in vivo measurements. The power efficiency indicated good performance of each channel and a maximum B1+ of 19 µT if the hardware RF power limits of the MR system were exploited. MR imaging of the shoulder was demonstrated with clinically excellent image quality and submillimeter spatial resolution. CONCLUSIONS: The presented 8-channel transceiver 7-channel receive RF coil setup was successfully applied for in vivo 7 T MRI of the shoulder providing a clear SNR gain vs the transceiver array without the additional receive array. Homogeneous images across the shoulder region were obtained using 8-channel subject-specific phase-only RF shimming.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Ondas de Rádio , Ombro/diagnóstico por imagem , Razão Sinal-Ruído , Humanos , Imagens de Fantasmas
8.
MAGMA ; 30(6): 591-607, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28695398

RESUMO

OBJECTIVE: A new technique for 2D gradient-recalled echo echo-planar imaging (GE-EPI) termed 'variable slice thickness' (VAST) is proposed, which reduces signal losses caused by through-slice susceptibility artifacts, while keeping the volume repetition time (TR) manageable. The slice thickness is varied across the brain, with thinner slices being used in the inferior brain regions where signal voids are most severe. MATERIALS AND METHODS: Various axial slice thickness schemes with identical whole-brain coverage were compared to regular EPI, which may either suffer from unfeasibly long TR if appropriately thin slices are used throughout, or signal loss if no counter-measures are taken. Evaluation is based on time-course signal-to-noise (tSNR) maps from resting state data and a statistical group-level region of interest (ROI) analysis on breath-hold fMRI measurements. RESULTS: The inferior brain region signal voids with static B0 inhomogeneities could be markedly reduced with VAST GE-EPI in contrast to regular GE-EPI. ROI-averaged event-related signal changes showed 48% increase in VAST compared to GE-EPI with regular "thick" slices. tSNR measurements proved the comparable signal robustness of VAST in comparison to regular GE-EPI with thin slices. CONCLUSION: A novel acquisition strategy for functional 2D GE-EPI at ultrahigh magnetic field is presented to reduce susceptibility-induced signal voids and keep TR sufficiently short for whole-brain coverage.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Artefatos , Encéfalo/anatomia & histologia , Encéfalo/fisiologia , Mapeamento Encefálico/métodos , Mapeamento Encefálico/estatística & dados numéricos , Suspensão da Respiração , Imagem Ecoplanar/estatística & dados numéricos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Fatores de Tempo
9.
F1000Res ; 3: 212, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26236464

RESUMO

Socially-relevant decisions are based on clearly recognizable but also not consciously accessible affective stimuli. We studied the role of the dorsolateral frontal cortex (DLFC) in decision-making on masked affect expressions using functional magnetic resonance imaging. Our paradigm permitted us to capture brain activity during a pre-decision phase when the subjects viewed emotional expressions below the threshold of subjective awareness, and during the decision phase, which was based on verbal descriptions as the choice criterion. Using meta-analytic connectivity modeling, we found that the preparatory phase of the decision was associated with activity in a right-posterior portion of the DLFC featuring co-activations in the left-inferior frontal cortex. During the subsequent decision a right-anterior and more dorsal portion of the DLFC became activated, exhibiting a different co-activation pattern. These results provide evidence for partially independent sub-regions within the DLFC, supporting the notion of dual associative processes in intuitive judgments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...