Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
JAMA Ophthalmol ; 140(2): 115-123, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34913968

RESUMO

IMPORTANCE: High myopia incidence and prevalence is increasing worldwide, and the visual burden caused by myopia is expected to rise accordingly. Studies investigating the occurrence of myopic complications in individuals of European ancestry with high myopia are scarce, hampering insights into the frequency of myopic retinal complications in European individuals and their visual burden. OBJECTIVE: To assess the frequency of myopic macular features in individuals of European ancestry with high myopia. DESIGN, SETTING, AND PARTICIPANTS: This cross-sectional analysis of the Dutch Myopia Study (MYST) and individuals with high myopia from the Rotterdam Study (RS) included 626 patients with high myopia (spherical equivalent of refractive error [SER] ≤-6 diopters [D] or axial length [AL] ≥26 mm) who underwent an extensive ophthalmic examination including multimodal retinal imaging. In addition to this combination of a population-based cohort study and mix-based high myopia study, a systematic literature review was also performed to compare findings with studies of individuals of Asian ancestry. EXPOSURES: High myopia, age, and AL. MAIN OUTCOMES AND MEASURES: Frequency of myopic macular and optic disc features: tessellated fundus, myopic macular degeneration (MMD), staphyloma, peripapillary intrachoroidal cavitation, peripapillary atrophy (PPA), and "plus" lesions (choroidal neovascularization, Fuchs spot, and lacquer cracks). RESULTS: The mean (SD) SER of the combined study population (MYST and RS) was -9.9 (3.2) D; the mean (SD) age was 51.4 (15.1) years, and 387 (61.8%) were women. The prevalence of MMD was 25.9% and increased with older age (P for trend <.001), lower SER (odds ratio [OR], 0.70; 95% CI, 0.65-0.76; P < .001), and higher AL (OR, 2.53; 95% CI, 2.13-3.06; P < .001). Choroidal neovascularization or Fuchs spot was present in 2.7% (n = 17), both lesions in 0.3% (n = 2), and lacquer cracks in 1.4% (n = 9). Staphyloma, PPA, and MMD were highly prevalent in visual impaired and blind eyes (frequency was 73.9% [20 of 27], 90.5% [19 of 21], and 63.0% [17 of 27] of unilateral blind eyes for MMD, staphyloma, and PPA, respectively). Seven previous studies in Asian populations reported a variable MMD frequency ranging from 8.3% to 64%, but frequencies were similar for comparable risk profiles based on age and SER. CONCLUSIONS AND RELEVANCE: In this cross-sectional study of a highly myopic Dutch population of European ancestry, myopic retinal features were frequent; were associated with age, SER, and AL; and occurred in all visually severely impaired eyes. The absence of treatment options for most of these retinal complications emphasizes the need for effective strategies to prevent high myopia.


Assuntos
Neovascularização de Coroide , Degeneração Macular , Miopia Degenerativa , Doenças Retinianas , Estudos de Coortes , Estudos Transversais , Feminino , Humanos , Degeneração Macular/diagnóstico , Masculino , Pessoa de Meia-Idade , Miopia Degenerativa/complicações , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/epidemiologia , Prevalência , Doenças Retinianas/diagnóstico , Acuidade Visual
2.
Invest Ophthalmol Vis Sci ; 57(13): 5593-5601, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27768796

RESUMO

PURPOSE: Reticular pseudodrusen (RPD) are considered to be a distinct feature in AMD. Population studies have studied the epidemiology of RPD using standard color fundus photographs (CFP). However, recent studies have shown that RPD are better imaged using near-infrared (NIR) imaging. We studied the epidemiology of RPD in a large population-based study using NIR and CFP. METHODS: Participants aged 65+ years from the Rotterdam Study underwent ophthalmologic examination including NIR and CFP. Both images were graded for the presence of RPD and soft indistinct drusen (SID). Associations with demographic and environmental factors, 26 genetic variants, and total genetic risk score were analyzed using logistic regression analysis. RESULTS: Reticular pseudodrusen were detected in 137 (4.9%) of 2774 study participants; of these, 92.7% were detected with NIR imaging and 38% on CFP. Most eyes with RPD showed presence of SID, whereas other drusen types coincided less frequently. Reticular pseudodrusen were significantly associated with age (odds ratio [OR] 1.21, 95% Confidence Interval [CI] 1.17-1.24) and female sex (OR 2.10, 95% CI 1.41-3.13). Environmental factors did not show a significant association with RPD. Major AMD risk variants were significantly associated with RPD and SID; however, ARMS2, C3, and VEGFA were more associated with RPD (RPD vs. SID P < 0.05). Total genetic risk score did not differ significantly (P = 0.88). CONCLUSION: Detection of RPD was better with NIR imaging than on CFP in a population-based setting. Presence of RPD often coincided with presence of SID; however, they showed quantitative differences in genetic risk profile.


Assuntos
Degeneração Macular/complicações , Vigilância da População , Drusas Retinianas/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Angiofluoresceinografia , Seguimentos , Fundo de Olho , Humanos , Incidência , Degeneração Macular/diagnóstico , Degeneração Macular/epidemiologia , Masculino , Microscopia Confocal , Países Baixos/epidemiologia , Razão de Chances , Prevalência , Estudos Prospectivos , Drusas Retinianas/diagnóstico , Drusas Retinianas/etiologia , Fatores de Risco , Tomografia de Coerência Óptica
3.
Invest Ophthalmol Vis Sci ; 56(1): 633-9, 2015 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-25574052

RESUMO

PURPOSE: To examine human performance and agreement on reticular pseudodrusen (RPD) detection and quantification by using single- and multimodality grading protocols and to describe and evaluate a machine learning system for the automatic detection and quantification of reticular pseudodrusen by using single- and multimodality information. METHODS: Color fundus, fundus autofluoresence, and near-infrared images of 278 eyes from 230 patients with or without presence of RPD were used in this study. All eyes were scored for presence of RPD during single- and multimodality setups by two experienced observers and a developed machine learning system. Furthermore, automatic quantification of RPD area was performed by the proposed system and compared with human delineations. RESULTS: Observers obtained a higher performance and better interobserver agreement for RPD detection with multimodality grading, achieving areas under the receiver operating characteristic (ROC) curve of 0.940 and 0.958, and a κ agreement of 0.911. The proposed automatic system achieved an area under the ROC of 0.941 with a multimodality setup. Automatic RPD quantification resulted in an intraclass correlation (ICC) value of 0.704, which was comparable with ICC values obtained between single-modality manual delineations. CONCLUSIONS: Observer performance and agreement for RPD identification improved significantly by using a multimodality grading approach. The developed automatic system showed similar performance as observers, and automatic RPD area quantification was in concordance with manual delineations. The proposed automatic system allows for a fast and accurate identification and quantification of RPD, opening the way for efficient quantitative imaging biomarkers in large data set analysis.


Assuntos
Diagnóstico por Computador , Processamento de Imagem Assistida por Computador , Imagem Multimodal , Drusas Retinianas/diagnóstico , Algoritmos , Inteligência Artificial , Estudos de Coortes , Angiofluoresceinografia , Humanos , Variações Dependentes do Observador , Fotografação , Estudos Prospectivos , Curva ROC , Espectroscopia de Luz Próxima ao Infravermelho
4.
Ophthalmology ; 110(8): 1540-4, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12917169

RESUMO

PURPOSE: To compare stereo digital images with stereo 35-mm color transparencies as to the quality and reliability of grading age-related maculopathy (ARM) in the context of a multicenter European epidemiologic study (the EUREYE Study). DESIGN: Instrument validation study. PARTICIPANTS: Ninety-one subjects (137 eyes) with varying degrees of ARM, including no ARM. METHODS: From both eyes of the participants, 35-mm film and digital stereoscopic fundus images were obtained with two identical Topcon fundus cameras. Two experienced graders classified all signs of ARM according to the International Classification System. Agreement between imaging techniques and between graders was calculated using the weighted kappa statistic. MAIN OUTCOME MEASURES: Signs of ARM (number, size, and morphologic characteristics of drusen; pigmentary changes; geographic atrophy; and neovascular macular degeneration) as well as an overall staging system of increasing ARM severity. RESULTS: The weighted kappa value for between-technique agreement ranged from 0.41 for number of drusen <63 microm to 0.79 for drusen type and total area occupied by drusen. The kappa values for atrophic and neovascular end-stage ARM were 0.87 and 0.94, respectively. The between-technique agreement on stages of ARM was approximately 0.76. The agreement between graders was largely the same for both techniques of imaging. CONCLUSIONS: In the described setting, digital images were as good as 35-mm film for the grading of ARM. Considering the practical advantages of digital imaging, this technique may serve well in epidemiologic studies of ARM.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Macula Lutea/patologia , Degeneração Macular/classificação , Fotografação/métodos , Idoso , Humanos , Degeneração Macular/epidemiologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...