Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anesthesiology ; 141(2): 353-364, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38718376

RESUMO

BACKGROUND: Unlike expired sevoflurane concentration, propofol lacks a biomarker for its brain effect site concentration, leading to dosing imprecision particularly in infants. Electroencephalography monitoring can serve as a biomarker for propofol effect site concentration, yet proprietary electroencephalography indices are not validated in infants. The authors evaluated spectral edge frequency (SEF95) as a propofol anesthesia biomarker in infants. It was hypothesized that the SEF95 targets will vary for different clinical stimuli and an inverse relationship existed between SEF95 and propofol plasma concentration. METHODS: This prospective study enrolled infants (3 to 12 months) to determine the SEF95 ranges for three clinical endpoints of anesthesia (consciousness-pacifier placement, pain-electrical nerve stimulation, and intubation-laryngoscopy) and correlation between SEF95 and propofol plasma concentration at steady state. Dixon's up-down method was used to determine target SEF95 for each clinical endpoint. Centered isotonic regression determined the dose-response function of SEF95 where 50% and 90% of infants (ED50 and ED90) did not respond to the clinical endpoint. Linear mixed-effect model determined the association of propofol plasma concentration and SEF95. RESULTS: Of 49 enrolled infants, 44 evaluable (90%) showed distinct SEF95 for endpoints: pacifier (ED50, 21.4 Hz; ED90, 19.3 Hz), electrical stimulation (ED50, 12.6 Hz; ED90, 10.4 Hz), and laryngoscopy (ED50, 8.5 Hz; ED90, 5.2 Hz). From propofol 0.5 to 6 µg/ml, a 1-Hz SEF95 increase was linearly correlated to a 0.24 (95% CI, 0.19 to 0.29; P < 0.001) µg/ml decrease in plasma propofol concentration (marginal R2 = 0.55). CONCLUSIONS: SEF95 can be a biomarker for propofol anesthesia depth in infants, potentially improving dosing accuracy and utilization of propofol anesthesia in this population.


Assuntos
Anestésicos Intravenosos , Eletroencefalografia , Propofol , Humanos , Propofol/sangue , Propofol/administração & dosagem , Lactente , Estudos Prospectivos , Eletroencefalografia/efeitos dos fármacos , Eletroencefalografia/métodos , Anestésicos Intravenosos/sangue , Anestésicos Intravenosos/administração & dosagem , Feminino , Masculino , Biomarcadores/sangue , Relação Dose-Resposta a Droga , Determinação de Ponto Final
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...