Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-31598512

RESUMO

The aim of this study was to compare the accuracy of 8 IOL power calculation formulas for eyes post-refractive surgery. In this Retrospective study, a chart review and data analysis of post-corneal refractive surgery patients who subsequently underwent cataract surgery with IOL implantation in Tertiary surgical center, Draper, UT, USA. The surgery was done in a single surgical center in Draper, UT by one surgeon. The study was approved by the organization's ethics board. The IOL power formulas used were Barrett True K (BTK), Average Pupil Power (APP), Shammas, Haigis, Galilei, Potvin-Hill Pentacam (PVP), OCT and Barrett True K No History (BTKNH). The percent of time each formula was within ±0.5 D and ±0.75 D of refractive prediction error was calculated. Statistical analysis was performed comparing these 8 methodologies at four post-operative follow-up time points and on the summative time points. Mean follow-up time periods were: 4 weeks, 3 months, 6 months, and 12 months. A total of 64 eyes were included in the study. All IOL formulas showed a myopic trend except APP and Shammas, which showed a hyperopic trend. All tests showed a statistically significant mean absolute value difference from zero. OCT, BTKNH, and BTK had consistently high percentages within ±0.5D and ±0.75 D of refractive error. Linear mixed model analysis showed a statistically significant change in predictive value over time for all formulas. Linear mixed model analysis suggests that it is inadequate to evaluate the performance of IOL power formulae in the short term. Longer-term follow-up is needed to determine accuracy as several factors can result in refractive changes greater than 3 months postoperatively. Our analysis did not demonstrate any formula that was clearly superior to the other methods for predicting IOL power at any time point.

2.
Artigo em Inglês | MEDLINE | ID: mdl-31598513

RESUMO

The purpose of this study was to report visual prognosis after explantation of a small-aperture corneal inlay used for the treatment of presbyopia. This is a retrospective case series conducted at a single site in Draper, Utah, USA (Hoopes Vision). Medical records of 176 patients who had received a small-aperture corneal inlay (KAMRA™, AcuFocus Inc., Irvine, CA, USA) were reviewed. Patients who had undergone explantation of the device were identified. Uncorrected distance visual acuity (UDVA), uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), and manifest refraction spherical equivalent (MRSE) were measured pre-implantation, post-implantation, pre-explantation, and post-explantation of the inlay. Ten eyes from ten patients were included in this study. The explantation rate was 5.7% over 31 months, with blurry vision as the most common complaint. After explantation, six patients achieved pre-implantation UDVA, and six achieved pre-implantation UNVA. Eight of nine patients who underwent final manifest refraction achieved pre-operative CDVA. All patients had residual donut-shaped corneal haze in the stroma at the previous position of the inlay. All patients experienced improvement in haze with 20% experiencing complete resolution. The degree of stromal haze was not related to the duration of implantation. Of the subset of patients who underwent explantation of their small-aperture corneal inlay, there was persistent loss of CDVA in 10%. The majority of patients experienced some level of residual stromal haze, which may contribute to deficits in UNVA and CDVA in few patients. A hyperopic shift induced by the corneal inlay may contribute to the blurry vision these patients experienced; there was a reduction of this shift post-explantation. While this device is removable, patients should expect some post-explantation changes such as residual haze with a small subset experiencing persistent deficits in CDVA.

3.
Artigo em Inglês | MEDLINE | ID: mdl-31598515

RESUMO

The purpose of this case series is to report visual outcomes in patients who underwent explantation of the Raindrop® hydrogel corneal inlay. Retrospective chart review comprising four cases of explantation of the Raindrop® corneal shape-changing hydrogel inlay: pre-implantation, pre-explantation, and post-explantation values for uncorrected distance visual acuity, uncorrected near visual acuity, and corrected distance visual acuity (CDVA) were measured; keratometric and tomographic data were collected using the Pentacam system (Oculus, Inc). Three eyes were explanted for progressive haze after implantation that persisted even after removal; one eye was explanted due to poor visual acuity with no haze formation. All patients experienced decreased unaided and corrected distance visual acuity. Persistent increase in corneal thickness and mean keratometry was noted post-explantation. All four patients regained their original near visual acuities, but one patient had persistent one-line loss in CDVA. There are long lasting tomographic corneal changes following Raindrop inlay explantation. In addition, persistent increased corneal thickness could be related to semi-permanent changes in corneal structure and may account for residual haze experienced by patients. After explantation, patients may not return to baseline CDVA.

4.
World J Clin Cases ; 7(19): 3012-3017, 2019 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-31624748

RESUMO

BACKGROUND: Known ocular manifestations of Alport syndrome include features such as anterior lenticonus and fleck retinopathy. Reports of keratoconus in such patients are limited. We report tomographic findings consistent with keratoconus in a patient with Alport syndrome. CASE SUMMARY: A 52-year-old female was referred to our ophthalmology clinic with decreased vision and increased tearing. She was diagnosed with stage III Alport syndrome two years prior. Upon examination she was found to have average keratometries of 48 D bilaterally with tomographic evidence of keratoconus. CONCLUSION: Although a rare presentation, concurrent Alport syndrome and keratoconus should be considered when reviewing the ocular health of Alport syndrome patients and appropriate management steps should be taken upon the diagnosis.

5.
Curr Opin Ophthalmol ; 30(1): 9-12, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30394990

RESUMO

PURPOSE OF REVIEW: To review the literature in 2017 and 2018 pertaining to biometry for cataract surgery and report pertinent findings. RECENT FINDINGS: New devices using swept-source ocular coherence tomography can measure axial length in dense cataracts more frequently than common biometers. Computer-assisted registration may be superior to intraoperative aberrometry for toric intraocular lens (IOL) placement. Soft contact lenses may not require removal as long before biometry as previously thought. The Barrett Universal II IOL formula has been found to perform well at all axial lengths. SUMMARY: New swept-source ocular coherence tomography biometers are more frequently successful at measuring axial length in dense cataracts which promises to improve refractive outcomes. Accuracy in toric IOL placement is likely to increase with improved devices. It may not be necessary to have patients remove soft contact lens any more than 2 days prior to biometry. The Barrett Universal II IOL formula may be used confidently for most eyes. Advancements acknowledged, purchasing new equipment will not be necessary for all surgeons.


Assuntos
Comprimento Axial do Olho/diagnóstico por imagem , Biometria/métodos , Extração de Catarata , Implante de Lente Intraocular , Tomografia de Coerência Óptica/métodos , Comprimento Axial do Olho/patologia , Humanos , Refração Ocular
6.
Ocul Surf ; 10(2): 100-7, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22482470

RESUMO

To determine the ratio of IGFBP3:IGF-1 in normal and diabetic human tears, and in telomerase-immortalized human corneal epithelial cells (hTCEpi) cultured under elevated glucose conditions and to correlate these changes with total and phosphorylated levels of IGF-1R. Tear samples were collected noninvasively from diabetic subjects and non-diabetic controls; corneal sensitivity was assessed using a Cochet-Bonnet Aesthesiometer. Conditioned media were collected following culture of hTCEpi cells in normal (5 mM) and elevated (25 mM) glucose conditions; mannitol was used as an osmotic control. IGFBP3, IGF-1, and phosphorylated IGF-1R levels were assessed by ELISA. IGFBP3 and IGF-1R mRNA were assessed by real-time polymerase chain reaction (PCR). Total and phosphorylated IGF-1R expression in whole cell lysates was assessed by western blot. There was a 2.8-fold increase in IGFBP3 in diabetic tears compared to non-diabetic controls (P=0.006); IGF-1 levels were not significantly altered. No difference in corneal sensitivity was detected between groups. The concentration of IGFBP3 in tears was independent of IGF-1. Consistent with human tear measurements in vivo, IGFBP3 secretion was increased 2.2 fold (P<0.001) following culture of hTCEpi cells under elevated glucose conditions in vitro. Treatment with glucose and the mannitol control reduced IGFBP3 mRNA (P<0.001). Total IGF-1R levels were unchanged. The increase in the IGFBP3:IGF-1 ratio detected in diabetic tears compared to normal controls blocked phosphorylation of the IGF-1R by IGF-1 (P<0.001) when tested in vitro. Taken together, these in vivo and confirmatory in vitro findings suggest that the observed increase in IGFBP3 found in human tears may attenuate IGF-1R signaling in the diabetic cornea. A long-term increase in IGFBP3 may contribute to epithelial compromise and the pathogenesis of ocular surface complications reported in diabetes.


Assuntos
Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 2/metabolismo , Epitélio Corneano/metabolismo , Proteína 3 de Ligação a Fator de Crescimento Semelhante à Insulina/metabolismo , Fator de Crescimento Insulin-Like I/metabolismo , Lágrimas/metabolismo , Adulto , Western Blotting , Células Cultivadas , Doenças da Córnea/metabolismo , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Proteína 3 de Ligação a Fator de Crescimento Semelhante à Insulina/genética , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase em Tempo Real , Receptor IGF Tipo 1/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...