Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Chromatogr ; 34(10): e4915, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32529647

RESUMO

This work presents a sensitive and rapid analytical method for the determination of oxcarbazepine in human plasma and urine samples. A vortex-assisted switchable hydrophilicity solvent-based liquid phase microextraction (VA-SHS-LPME) was used to preconcentrate oxcarbazepine from the samples before the determination by gas chromatography mass spectrometry. The switchable hydrophilicity solvent was synthesized by protonating N,N-dimethylbenzylamine with carbon dioxide to make it totally miscible with an equivalent volume of water. Parameters of the VA-SHS-LPME method including volume of switchable hydrophilicity solvent, concentration/volume of sodium hydroxide and vortex period were systematically optimized. Under the optimum conditions, good linearity ranging from 27.03 to 353.47 µg/kg was obtained for the analyte. Limit of detection and quantitation values were found to be 6.2 and 21 µg/kg (mass base), respectively. The relative standard deviation was calculated as 6.9% for six replicate measurements of the lowest concentration of the calibration plot. Satisfactory recovery results were calculated in the range of 97-100% for human plasma and urine samples spiked at five different concentrations.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Oxcarbazepina/sangue , Oxcarbazepina/urina , Humanos , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Modelos Lineares , Oxcarbazepina/química , Reprodutibilidade dos Testes , Solventes/química
2.
Environ Monit Assess ; 192(5): 273, 2020 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-32266493

RESUMO

An accurate and sensitive dispersive liquid-liquid microextraction method based on binary solvents was used to enrich prothiofos, oxadiargyl, and gamma-cyhalothrin for quantification by GC-MS. The combination of two extraction solvents (binary mixture) resulted in higher extraction efficiencies compared to the single solvent extraction systems. Parameters of the binary extraction method where optimized to enhance the extraction output of the analytes. The limits of detection calculated for the analytes ranged between 0.59 and 1.6 ng/mL. Linear calibration plots of the analytes covered wide concentration ranges with R2 values greater than 0.9996 and percent relative standard deviation lower than 10%. Spiked recovery experiments were performed well and wastewater at two different concentrations and satisfactory results (89-104%) were obtained. The binary solvent microextraction method was combined with QuEChERS to quantify the analytes in pineapple matrix, using matrix matching method to enhance the accuracy of the method to almost 100%.


Assuntos
Microextração em Fase Líquida , Poluentes Químicos da Água , Ananas/química , Monitoramento Ambiental , Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção , Nitrilas/análise , Organotiofosfatos/análise , Oxidiazóis/análise , Piretrinas/análise , Solventes , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...