1.
Clin Neuroradiol ; 24(4): 337-45, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24346229

RESUMO

PURPOSE: To define K(trans) and fractional anisotropy (FA) thresholds in correlation to histology for improved magnetic resonance imaging (MRI) tumor assessment in an animal model of brain glioma. METHODS: Twelve rats underwent 4.7 T MRI at day 10 after tumor implantation. Anatomical scans (T2, T1 at 8 min after double dose contrast application) as well as dynamic contrast-enhanced (DCE) imaging with calculation of K(trans) and diffusion tensor imaging (DTI) with calculation of FA were performed. T2- and T1-derived tumor volumes were calculated and thresholds for K(trans) and FA were defined for best MRI tumor assessment correlated to histology. RESULTS: Tumor volumes were 159 ± 14 mm(3) (histology), 126 ± 26 mm(3) (T1 with contrast, r=0.76), and 153 ± 12 mm(3) (T2, r=0.84), respectively. K(trans)- and FA-derived tumor volumes were 160 ± 16 mm(3) (for K(trans ≥ 0.04 min(-1), r=0.94), and 159 ± 14 mm(3) (for FA £0.14, r=0.96), respectively. CONCLUSIONS: DCE-MRI and DTI with calculation of K(trans) and FA maps allow very precise brain glioma assessment comparable to histology if established thresholds for the given tumor model are used.


Assuntos
Algoritmos , Neoplasias Encefálicas/patologia , Imagem de Tensor de Difusão/métodos , Glioma/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Carga Tumoral , Animais , Linhagem Celular Tumoral , Estudos de Viabilidade , Ratos , Ratos Endogâmicos F344 , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Thorac Cardiovasc Surg ; 59(2): 85-92, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21384304

RESUMO

BACKGROUND: Transplant arteriosclerosis is still the leading cause of late mortality after heart transplantation despite advances in immunosuppression regimes. Experimental mouse models have substantially contributed to a better understanding of the multifactorial pathogenesis, but the major limitation of these studies is the difficulty in monitoring progression of transplant arteriosclerosis over time. Therefore, the aim of this study was to investigate whether MR measurements are sensitive enough to detect characteristic vascular lesions in a small animal transplantation model. METHODS: For this purpose we investigated 22 iso- and allogeneic aortic graft transplanted mice in vivo with a 4.7 T MR scanner using a 2D-RARE technique, 3D time-of-flight angiography and 3D phase contrast angiography as well as a special snake-based reconstruction algorithm. The MR lumen values of patency from native images and from 3D vessel reconstructions of the respective methods were correlated with conventional histological analysis. RESULTS: A comparison of the different techniques showed that angiographic MR modalities correlated well with histological measurements. 2D-RARE sequences were inferior to the sequences obtained by other ones. Superior correlations and the most accurate results were found for vessel reconstruction based on 3D angiographic time-of-flight data. CONCLUSION: These data demonstrate that mouse in vivo MR imaging is sensitive enough to detect and quantify vascular changes caused by transplant arteriosclerosis.


Assuntos
Aorta Abdominal/transplante , Arteriosclerose/patologia , Angiografia por Ressonância Magnética , Enxerto Vascular/efeitos adversos , Algoritmos , Animais , Aorta Abdominal/patologia , Arteriosclerose/etiologia , Modelos Animais de Doenças , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos CBA , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Transplante Autólogo , Transplante Isogênico
3.
AJNR Am J Neuroradiol ; 22(5): 969-76, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11337344

RESUMO

BACKGROUND AND PURPOSE: The purposes of this study were to find the role of diffusion-weighted MR imaging in characterizing intracerebral masses and to find a correlation, if any, between the different parameters of diffusion-weighted imaging and histologic analysis of tumors. The usefulness of diffusion-weighted imaging and apparent diffusion coefficient (ADC) maps in tumor delineation was evaluated. Contrast with white matter and ADC values for tumor components with available histology were also evaluated. METHODS: Twenty patients with clinical and routine MR imaging/CT evidence of intracerebral neoplasm were examined with routine MR imaging and echo-planar diffusion-weighted imaging. The routine MR imaging included at least the axial T2-weighted fast spin-echo and axial T1-weighted spin-echo sequences before and after contrast enhancement. The diffusion-weighted imaging included an echo-planar spin-echo sequence with three b values (0, 300, and 1200 s/mm(2)), sensitizing gradient in the z direction, and calculated ADC maps. The visual comparison of routine MR images with diffusion-weighted images for tumor delineation was performed as was the statistical analysis of quantitative diffusion-weighted imaging parameters with histologic evaluation. RESULTS: For tumors, the diffusion-weighted images and ADC maps of gliomas were less useful than the T2-weighted spin-echo and contrast-enhanced T1-weighted spin-echo images in definition of tumor boundaries. Additionally, in six cases of gliomas, neither T2-weighted spin-echo nor diffusion-weighted images were able to show a boundary between tumor and edema, which was present on contrast-enhanced T1-weighted and/or perfusion echo-planar images. The ADC values of solid gliomas, metastases, and meningioma were in the same range. In two cases of lymphomas, there was a good contrast with white matter, with strongly reduced ADC values. For infection, the highest contrast on diffusion-weighted images and lowest ADC values were observed in association with inflammatory granuloma and abscess. CONCLUSION: Contrary to the findings of previous studies, we found no clear advantage of diffusion-weighted echo-planar imaging in the evaluation of tumor extension. The contrast between gliomas, metastases, meningioma, and white matter was generally lower on diffusion-weighted images and ADC maps compared with conventional MR imaging. Unlike gliomas, the two cases of lymphomas showed hyperintense signal on diffusion-weighted images whereas the case of cerebral abscess showed the highest contrast on diffusion-weighted images with very low ADC values. Further study is required to find out whether this may be useful in the differentiation of gliomas and metastasis from lymphoma and abscess.


Assuntos
Neoplasias Encefálicas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Encefalopatias/diagnóstico , Neoplasias Encefálicas/patologia , Difusão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
MAGMA ; 7(1): 21-7, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9877456

RESUMO

NMR signal phase variation caused by macroscopic motion of an object during application of the diffusion gradient is a well-known effect in diffusion-weighted imaging (DWI) using the standard pulsed gradient spin-echo sequence (PGSE). This phase error causes severe ghost artifacts in the output image when phase encoding techniques, such as two dimensional Fourier transform (2DFT) imaging, are used. One possible way to eliminate the motion effects is the navigator echo technique. The method is based on estimating the phase error from the navigator echo and using it for the correction of the image echo. The phase errors (zero and first order) for the phase correction of the image echo are usually evaluated from the navigator echo after Fourier transform (FT) in the readout direction, correcting for both translation and rotation. We present here a simple algorithm which enables evaluation and correction in the time domain of phase errors induced by motion. This approach has the advantage of improved correction of motional artifacts and minimized sensitivity to noise and inaccurate setting up of the experiment.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Algoritmos , Simulação por Computador , Análise de Fourier , Coração/anatomia & histologia , Coração/fisiologia , Humanos , Sensibilidade e Especificidade
6.
J Magn Reson ; 124(2): 323-42, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9169219

RESUMO

The study compared the results of three centrally reordered phase-encoded turboFLASH sequences for diffusion-weighted imaging (DWI). The sequences were conventional turboFLASH, turboFLASH with subtraction of T1-related effects, and turboFLASH with correction for T1-related effects during the imaging period only. The relative merits were studied with respect to image quality and accuracy by computer simulation and by experimental validation on phantoms and on in vivo rat brain. A T1-related underestimation of the diffusion coefficient ranging from -30% (T1 approximately 200 ms) to -5% (T1 approximately 1 s) was found to exist for the conventional sequence. Image artifacts, caused by longitudinal relaxation during the imaging period, are reflected in calculated diffusion maps. When the correction sequence is used, the artifacts and the systematic errors are reduced but longitudinal relaxation during the delay between preparation and imaging periods remains large enough to induce significant errors (-15% for T1 approximately 200 ms to -3% for T1 approximately 1 s). The subtraction sequence eliminates the influence of T1 effects on the calibrations, but leads to identical artifacts for all diffusion-weighted images.


Assuntos
Encéfalo/patologia , Simulação por Computador , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Animais , Mapeamento Encefálico/instrumentação , Infarto Cerebral/diagnóstico , Infarto Cerebral/fisiopatologia , Difusão , Feminino , Imagens de Fantasmas , Ratos , Ratos Wistar , Técnica de Subtração/instrumentação
7.
Magn Reson Imaging ; 10(3): 461-4, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1406096

RESUMO

This paper describes the influence of the transition distortion of gradient amplifiers on direct Fourier NMR imaging techniques. We demonstrate artifacts arising in the real measurement of the spin density images. Image artifacts are compared with artifacts obtained by computer simulations of the transition distortion of gradient amplifiers.


Assuntos
Espectroscopia de Ressonância Magnética , Artefatos , Mãos/anatomia & histologia , Humanos , Espectroscopia de Ressonância Magnética/métodos , Modelos Estruturais
8.
Magn Reson Imaging ; 8(4): 483-9, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2392035

RESUMO

We describe a technique for simulation and correction of the effects of an arbitrary distribution of undesired components of the static and gradient magnetic fields. This technique is applicable to direct Fourier NMR imaging. The mathematical basis and details of this technique are fully described. Computer simulation demonstrates the effectiveness of this method.


Assuntos
Simulação por Computador , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Encéfalo/anatomia & histologia , Análise de Fourier , Mãos/anatomia & histologia , Humanos
SELEÇÃO DE REFERÊNCIAS