Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
1.
J Conserv Dent Endod ; 27(6): 639-643, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38989497

RESUMO

Aims: This ex vivo study aimed to assess the dissolving capacity of 2.5% sodium hypochlorite using eight agitation protocols within swine pulp tissue. Subjects and Methods: Twelve lower first premolars were prepared and split into the fragments with a groove housing porcine dental pulp. Groups were assigned based on agitation systems: manual, passive ultrasonic, Easy Clean and XP-Endo Finisher. Two agitation time protocols were applied: One min (3 s × 20 s cycles) and 2 min (6 s × 20 s cycles). Wilcoxon Mann-Whitney U test was used to compare the groups. Results: Both time frames demonstrated superior results compared to manual group (P > 0.5). However, in the two min groups, no significant differences were observed among the other protocols (P < 0.5). Intriguingly, increasing cycle numbers significantly improved results within each group (P > 0.5). Conclusion: Extending the chemical agitation time during final irrigation enhances tissue removal, regardless of the irrigation protocol employed.

2.
Int J Dent ; 2024: 6628146, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38938694

RESUMO

This study aimed to evaluate the effect of autoclave sterilization on the integrity and instruments' fracture number after multiple uses and cyclic fatigue of the original WaveOne Gold (Dentsply Sirona Endodontics) compared to four replica-like instruments (TF4-Gold, Roll-Wave-Gold, W-File, and Micro-Gold). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). One hundred and fifty human molars, freshly extracted for orthodontic reasons or periodontal disease and with severe curvature (between 30° and 60°), were used. Fifty teeth were instrumented with 10 instruments from each group and were evaluated for integrity. After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more, totaling three rounds of instrumentation, sterilization, and SEM analysis. Ten unused instruments from each group were evaluated for resistance to cyclic fatigue in a static test using a motor and a device simulating a canal with a 60° curvature angle. The instruments were driven by the motor until separation, visually verified, and the time measured in seconds. Data were analyzed by Chi-square, one-way ANOVA, and Tukey analysis, considering a significance level of 5%. It was found that there was no statistically significant difference between the groups tested in the effect of sterilization on the number of uses. The SEM analysis showed distortions in the instruments after the 3rd use. There was a statistically significant difference in the cyclic fatigue test between the results of WaveOne Gold, TF4 Gold, and Roll Wave Gold compared to W File and Micro Gold (P < 0.0001) and a statistically significant difference between the W File and Micro Gold groups (P < 0.0001). In conclusion, this study affirmed that WaveOne Gold, TF4-Gold, and Roll-Wave-Gold instruments exhibit comparable cyclic fatigue resistance. Besides, all examined instruments can be reliably employed for up to two cases.

3.
Aust Endod J ; 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773855

RESUMO

To use scanning electron microscopy and energy dispersive X-ray spectroscopy to evaluate the metallurgical-chemical changes of WaveOne Gold (WOG) and R-Motion (RM), after multiple uses. The instruments were divided into groups (n = 8): WOG and RM-control groups, new instruments; WOG1 and RM1; WOG2 and RM2; WOG3 and RM3 after instrumentation of 1, 2 or 3 molars, respectively. Burrs occurred mainly in the control group and after the first use. The RM files were found to have a higher nickel content, which increased during reuse, and a decrease in oxygen content with increasing reuse, in addition to calcium impregnation, which occurred in greater amounts in the corrosion areas in the WOG files. The presence of topographic and chemical changes was demonstrated, indicating that caution should be taken when reusing endodontic instruments to avoid fractures.

4.
Meat Sci ; 213: 109483, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38484580

RESUMO

This study investigated the use of infrared thermography (IRT) to identify the dark, firm, and dry (DFD) phenomenon in Brazilian beef, which is a significant concern for the industry because of its inferior quality and reduced shelf life. This study examined 113 Nellore bulls and analyzed their minimum and maximum ocular temperatures using IRT. The results highlight the efficacy of thermal images (IRTmax) as a significant predictor, with R2 values ranging from 0.84 to 0.88 for calibration models. The inclusion of parameters such as glucose and lactate further enhanced prediction accuracy. The models also revealed that the combination of features, such as lightness (L*), redness (a*), and yellowness (b*), contributed to the precise prediction of pHu, with an R2 of 0.88. In model validation, RMSEP ranged from 0.104 to 0.158, indicating good generalization capability. The RPD, ranging from 1.7 to 2.6, suggests satisfactory quantitative prediction. The statistical significance of all models, evidenced by P-values <0.001, strengthens the reliability of the results. In conclusion, the models support the use of IRT as a tool for identifying pHu alterations in carcasses. When combined with blood parameters, they may exhibit even greater efficiency in predicting pHu in Nelore cattle carcasses, highlighting the potential applicability of these methods in the beef industry.


Assuntos
Carne Vermelha , Termografia , Animais , Bovinos , Termografia/veterinária , Termografia/métodos , Concentração de Íons de Hidrogênio , Carne Vermelha/análise , Masculino , Cor , Raios Infravermelhos , Qualidade dos Alimentos , Reprodutibilidade dos Testes , Brasil
5.
J Endod ; 50(3): 376-380, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38147908

RESUMO

INTRODUCTION: The purpose of this study was to evaluate the ability of the Reciproc, Reciproc Blue, and WaveOne Gold systems to remove filling material during endodontic retreatment of extracted human mandibular premolars. METHODS: Thirty-nine teeth were instrumented with the Protaper Universal System to the F3 file and filled with the Tagger hybrid technique using an F3 gutta-percha cone and AH Plus cement. At the end of this period, the teeth were scanned with micro-computed tomography before and after removal of the filling material from the root canals. The teeth were divided into 3 groups (n = 13) based on the apical volume, depending on the systems used to remove the filling material. Group GR: Reciproc 40/.06; Group GRB: Reciproc Blue 40/.06; and Group GWG: WaveOne Gold 35/.06. The results were statistically analyzed using the tests of Kruskal-Wallis, Duncan, and analysis of variance at a significance level of 5%. RESULTS: The results showed that there were no significant differences between the amounts of filling material removed, either for the apical and middle regions alone or in the overall evaluation for the 3 groups (P = .97). The time evaluation statistically showed that the GR and GWG groups required less time to clean the root canals than the GRB group. CONCLUSIONS: Reciproc R40 files and WaveOne Gold Medium files required less time for endodontic treatment than Reciproc Blue R40 files. There was no difference in the ability to remove obturation material between the 3 instruments. No instrument was able to completely remove the filling material from the root canals.


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Microtomografia por Raio-X/métodos , Cavidade Pulpar/diagnóstico por imagem , Obturação do Canal Radicular/métodos , Preparo de Canal Radicular , Retratamento , Guta-Percha
6.
Aust Endod J ; 50(1): 148-156, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38146083

RESUMO

The aim of this study was to assess by confocal laser microscope the depth of dentinal tubule penetration of two tricalcium silicate-based sealers promoted by two obturation techniques in curved canals compared with AHPlus. One hundred and twenty canals were divided into six groups (n = 20): BCSC-Bio-C Sealer (BC) and single-cone technique (SC); BCCW-BC and continuous condensation wave (CW); TFSC-Total Fill (TF) and SC; TFCW-TF and CW; AHSC-AH Plus (AH) and SC; AHCW-AH and CW. Data were analysed using the three-way ANOVA and Tukey's test (α = 5%). Penetration depth was significantly greater for TFCW than TFSC and greater for AHCW than AHSC (p < 0.05). There was no significant difference between BCCW and BCSC (p > 0.05). The penetration of TF was significantly greater (p < 0.05). The CW technique promoted greater intratubular penetration, except for the BC sealer.


Assuntos
Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular/métodos , Compostos de Cálcio , Silicatos , Resinas Epóxi
7.
Braz. j. oral sci ; 23: e243355, 2024. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1551649

RESUMO

Aim: This study aimed to perform an in vitro comparative analysis of the antifungal activity of different calcium silicate-based endodontic sealers against three fungal species. Methods: The antifungal properties of three calcium silicate-based sealers were tested: Bio-C Sealer, Cambiar a Sealer Plus BC, and MTA-Fillapex. Two commonly used sealers were used as controls: AH Plus and Endomethasone. An agar diffusion test was performed to analyze the antifungal activity of the sealers against Candida albicans, Candida glabrata, Candida tropicalis, and a mixed microbial culture medium. The results were analyzed using ANOVA (p <0.05). Results: Endomethasone exhibited the highest inhibition against all strains examined, maintaining a consistent level of inhibition throughout 7 days. MTA-Fillapex demonstrated the best performance among the calcium silicate-based sealers for the three fungal species (p < 0.05), maintaining stable values over the 7 days, surpassing that of Endomethasone. Nevertheless, MTA-Fillapex only exhibited antimicrobial effect against the mixed culture for the first 24 hours, and no antimicrobial activity was observed at 48 hours, being surpassed by all tested sealers (p < 0.05). Conclusion: Of all silicate-based sealers tested, only MTA-Fillapex exhibited promising antifungal activity. Nevertheless, care must be taken when extrapolating these results, as MTA-Fillapex exhibited poor antimicrobial activity when tested in mixed microbial cultures


Assuntos
Materiais Restauradores do Canal Radicular , Cimento de Silicato , Bactérias , Candida albicans , Candida glabrata , Candida tropicalis , Endodontia , Antifúngicos/análise
8.
J Clin Exp Dent ; 15(11): e895-e903, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38074171

RESUMO

Background: The success of endodontic treatment can be influenced by the type of endodontic sealer used, as certain sealers may be prone to apical microleakage, leading to treatment failure. The limitations of currently available sealers necessitate the development of new materials to improve the success rate of endodontic treatment. Therefore, the objective of this study was to assess the apical microleakage of newly developed hydroxyapatite-based endodontic sealers, including one derived from eggshells, and compare them with other commercially available sealers. Material and Methods: Eighty-five extracted human upper anterior teeth were selected for this study. The teeth were divided into 5 experimental groups and 2 control groups. The experimental groups were designated as follows: (1) HPSINT - obturated with gutta-percha cone and synthetic hydroxyapatite-based sealer, (2) BIOC - obturated with gutta-percha cone and Bio C-Sealer sealer, (3) AHPLUS-BC - obturated with gutta-percha cone and AHPLUS Bioceramic sealer, (4) AHP - obturated with gutta-percha cone and AHPLUS sealer, and (5) HPO - obturated with gutta-percha cone and sealer based on hydroxyapatite extracted from eggshells. Additionally, there were positive and negative control groups consisting of instrumented teeth filled with gutta-percha cones without any sealer and instrumented teeth without any filling, respectively. Methylene blue dye penetration was used to assess apical microleakage. Descriptive statistical analysis and Shapiro-Wilk normality test were applied to the observed results. As the samples followed a normal distribution, the ANOVA test was applied. Results: The control groups confirmed the validity of the experimental method, while the experimental groups showed varying degrees of dye penetration. The group obturated with Bio C-Sealer exhibited the highest mean apical microleakage, while AHPLUS Bioceramic sealer demonstrated lower mean than AHPLUS sealer and sealer based on hydroxyapatite extracted from eggshells (p<0.05). Finally, there was no difference between the synthetic hydroxyapatite-based sealer and AHPLUS Bioceramic sealer, AHPLUS sealer and sealer based on hydroxyapatite extracted from eggshells (p>0.05). No significant difference was observed between the hydroxyapatite-based sealers and the AHPLUS-BC sealer. Conclusions: The results of this study suggest that the newly developed hydroxyapatite-based endodontic sealers, including the one derived from eggshells, may have a lower risk of apical microleakage compared to other commercially available sealers. These findings highlight the potential of hydroxyapatite-based sealers to improve the success rate of endodontic treatment. Further research and clinical studies are warranted to validate these results and explore the long-term effects of these novel sealers. Key words:Endodontic treatment, apical microleakage, endodontic sealer, hydroxyapatite, eggshell-derived sealer.

9.
Sci Rep ; 13(1): 22956, 2023 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-38151487

RESUMO

This study aimed to evaluate the effect of the number of uses and autoclave sterilization on the cyclic fatigue resistance of four replica-like instruments RC Blue; Only One File Blue; Recip One Blue; and Micro Blue compared to the original system Reciproc Blue (VDW, Munich, Germany). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). Fifty molars were instrumented by ten instruments (n=10). After sterilization in an autoclave, the  instruments were analyzed by SEM. This procedure was repeated twice more using different molars, totaling 3 rounds of instrumentation, sterilization and SEM analysis. Then, ten different instruments from each brand were tested for cyclic fatigue resistance. Number of uses data were analyzed using Chi-squared analysis, and cyclic fatigue data were analyzed by one-way Anova followed by Tukey's test as the data had normal distribution. The fracture times for all systems had no significant difference, but Micro Blue had significantly lower values than the other systems (p < 0.05). The SEM analysis showed distortions in the instruments after the 3rd use. Therefore, all tested instruments except of Micro Blue have similar resistance to cyclic fatigue, and all are reliable for use in up to 2-cases.


Assuntos
Preparo de Canal Radicular , Esterilização , Falha de Equipamento , Estresse Mecânico , Teste de Materiais , Desenho de Equipamento , Titânio
10.
Braz Dent J ; 34(3): 33-41, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37466523

RESUMO

This in vitro study compared the antimicrobial efficacy of 2.5% sodium hypochlorite (NaOCl) and 8 µg/mL ozonated water agitated by passive ultrasonic irrigation (PUI) or PUI combined with EndoActivator (EA) against mature multispecies biofilm. One hundred and five oval-shaped mandibular premolars were instrumented, sterilized, and inoculated with Enterococcus faecalis, Candida albicans, and Staphylococcus aureus, divided into: control group - saline; O3 group - ozonated water; O3 PUI group - ozonated water with PUI agitation; O3 PUI+EA group - ozonated water with PUI+EA agitation; NaOCl group - NaOCl; NaOCl PUI group - NaOCl with PUI agitation; and NaOCl PUI+EA group - NaOCl with PUI+EA agitation. Microbiological samples were collected before (S1) and after (S2) the disinfection procedures and the data were statistically analyzed using the Kruskal-Wallis test. In the culture method, there was significant disinfection in the O3 PUI+EA, NaOCl, NaOCl PUI, and NaOCl PUI+EA groups (p˂0.05). The combination of NaOCl with PUI+EA reduced microbial counts to zero (p˂0.05). In the qPCR method, there was a significant reduction in the total count of viable microorganisms in the O3 PUI, O3 PUI+EA, NaOCl, NaOCl PUI, and NaOCl PUI+EA groups (p˂0.05). It can be concluded that 2.5% NaOCl with and without agitation, as well as 8 µg/mL ozonated water with its action enhanced by the agitation techniques, were effective in root canal disinfection, and their antimicrobial efficacy is related to the microorganisms present in the biofilm.


Assuntos
Anti-Infecciosos , Hipoclorito de Sódio , Hipoclorito de Sódio/farmacologia , Cavidade Pulpar/microbiologia , Anti-Infecciosos/farmacologia , Tratamento do Canal Radicular , Biofilmes , Enterococcus faecalis , Irrigantes do Canal Radicular , Preparo de Canal Radicular/métodos
11.
Braz. dent. j ; 34(3): 33-41, May-June 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1447599

RESUMO

Abstract This in vitro study compared the antimicrobial efficacy of 2.5% sodium hypochlorite (NaOCl) and 8 µg/mL ozonated water agitated by passive ultrasonic irrigation (PUI) or PUI combined with EndoActivator (EA) against mature multispecies biofilm. One hundred and five oval-shaped mandibular premolars were instrumented, sterilized, and inoculated with Enterococcus faecalis, Candida albicans, and Staphylococcus aureus, divided into: control group - saline; O3 group - ozonated water; O3 PUI group - ozonated water with PUI agitation; O3 PUI+EA group - ozonated water with PUI+EA agitation; NaOCl group - NaOCl; NaOCl PUI group - NaOCl with PUI agitation; and NaOCl PUI+EA group - NaOCl with PUI+EA agitation. Microbiological samples were collected before (S1) and after (S2) the disinfection procedures and the data were statistically analyzed using the Kruskal-Wallis test. In the culture method, there was significant disinfection in the O3 PUI+EA, NaOCl, NaOCl PUI, and NaOCl PUI+EA groups (p˂0.05). The combination of NaOCl with PUI+EA reduced microbial counts to zero (p˂0.05). In the qPCR method, there was a significant reduction in the total count of viable microorganisms in the O3 PUI, O3 PUI+EA, NaOCl, NaOCl PUI, and NaOCl PUI+EA groups (p˂0.05). It can be concluded that 2.5% NaOCl with and without agitation, as well as 8 µg/mL ozonated water with its action enhanced by the agitation techniques, were effective in root canal disinfection, and their antimicrobial efficacy is related to the microorganisms present in the biofilm.


Resumo Este estudo in vitro comparou a desinfecção do hipoclorito de sódio 2,5% (NaOCl) e da água ozonizada 8 µg/mL agitados pela irrigação ultrassônica passiva (PUI) e por associação da PUI com EndoActivator (EA) na redução de biofilme misto maduro. Cento e cinco pré-molares inferiores ovalados foram instrumentados, esterilizados e inoculados com Enterococcus faecalis, Candida albicans e Staphylococcus aureus, divididos em: Grupo controle: soro; Grupo O3: água ozonizada; Grupo O3 PUI: água ozonizada agitada por PUI; Grupo O3 PUI + EA: água ozonizada agitada por PUI e EA: Grupo NaOCl: hipoclorito de sódio; Grupo NaOCl PUI: hipoclorito de sódio agitado por PUI; Grupo NaOCl PUI + EA: hipoclorito de sódio agitado por PUI e EA. Amostras microbiológicas foram coletadas antes (S1) e após (S2) os procedimentos de desinfecção e os dados foram analisados estatisticamente pelo teste de Kruskal-Wallis. No método de cultura, houve desinfecção significativa nos grupos O3 PUI + EA, NaOCl, NaOCl PUI e NaOCl PUI + EA (p˂0.05), sendo que no grupo NaOCl PUI + EA não houve crescimento de microrganismo (p˂0.05). No método de qPCR, nas contagens dos microrganismos antes e após os protocolos de desinfecção, houve redução microbiana nos grupos O3 PUI, O3 PUI + EA, NaOCl, NaOCl PUI, NaOCl PUI + EA (p˂0.05). Concluiu-se que o NaOCl 2,5% com e sem agitação foi eficiente, assim como a água ozonizada 8 µg/mL potencializada pelos métodos de agitação na desinfecção e que a mesma está relacionada com os microrganismos presentes no biofilme.

12.
Bioengineering (Basel) ; 10(5)2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37237680

RESUMO

The aim of this study was to histologically verify the performance of pulp-derived stem cells used in the pulp-dentin complex regeneration. Maxillary molars of 12 immunosuppressed rats were divided into two groups: the SC (stem cells) group, and the PBS (just standard phosphate-buffered saline) group. After pulpectomy and canal preparation, the teeth received the designated materials, and the cavities were sealed. After 12 weeks, the animals were euthanized, and the specimens underwent histological processing and qualitative evaluation of intracanal connective tissue, odontoblast-like cells, intracanal mineralized tissue, and periapical inflammatory infiltrate. Immunohistochemical evaluation was performed to detect dentin matrix protein 1 (DMP1). In the PBS group, an amorphous substance and remnants of mineralized tissue were observed throughout the canal, and abundant inflammatory cells were observed in the periapical region. In the SC group, an amorphous substance and remnants of mineralized tissue were observed throughout the canal; odontoblasts-like cells immunopositive for DMP1 and mineral plug were observed in the apical region of the canal; and a mild inflammatory infiltrate, intense vascularization, and neoformation of organized connective tissue were observed in the periapical region. In conclusion, the transplantation of human pulp stem cells promoted partial pulp tissue neoformation in adult rat molars.

13.
J Endod ; 49(7): 889-893, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37225038

RESUMO

INTRODUCTION: The aim of the present study was to investigate ex vivo by confocal laser scanning microscopy the antibacterial effect of photodynamic therapy (PDT) on dentinal tubules in the apical 5 mm of human mandibular premolars contaminated with Enterococcus faecalis. METHODS: Thirty-four teeth were standardized to 20 mm and foraminal anatomic diameters using a #20 K-file (Dentsply Maillefer). Samples were contaminated for 21 days and divided into the following 3 experimental groups (n = 10): the PDT group (instrumented canals and PDT), the passive ultrasonic irrigation (PUI) group (instrumented canals and PUI), and the PUI-PDT group (instrumented canals, PUI, and PDT), along with a control group (n = 4) (noninstrumented canals). The canals in the experimental groups were instrumented with ProTaper Next (Dentsply Maillefer) up to X3 and rinsed with EDTA and sodium hypochlorite. The photosensitizer used was 0.01% methylene blue with a preirradiation time of 5 minutes and a diode laser with 4 J energy and a 660-nm wavelength. Cross sections were made 5 mm from the apex of all samples, which were analyzed using confocal laser scanning microscopy. The results were analyzed using the Shapiro-Wilk and Kruskal-Wallis (Dunn) tests. RESULTS: There was a lower percentage of live bacteria in the PUI-PDT group, with a statistical difference compared with the control and PDT groups (P < .05). There was no statistical difference in the percentage of live bacteria between PUI-PDT and PUI (P > .05). CONCLUSIONS: It was concluded that the PUI-PDT association was most effective in disinfecting root canals compared with the control group and PDT.


Assuntos
Enterococcus faecalis , Fotoquimioterapia , Humanos , Cavidade Pulpar/microbiologia , Hipoclorito de Sódio/farmacologia , Hipoclorito de Sódio/uso terapêutico , Microscopia Confocal , Irrigantes do Canal Radicular , Fotoquimioterapia/métodos , Preparo de Canal Radicular/métodos
14.
Imaging Sci Dent ; 53(1): 11-19, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37006793

RESUMO

Purpose: This study compared the accuracy of detection of incomplete vertical root fractures (VRFs) in filled and unfilled teeth on cone-beam computed tomography images with and without a metal artefact reduction (MAR) algorithm. Materials and Methods: Forty single-rooted maxillary premolars were selected and, after endodontic instrumentation, were categorized as unfilled teeth without fractures, filled teeth without fractures, unfilled teeth with fractures, or filled teeth with fractures. Each VRF was artificially created and confirmed by operative microscopy. The teeth were randomly arranged, and images were acquired with and without the MAR algorithm. The images were evaluated with OnDemand software (Cybermed Inc., Seoul, Korea). After training, 2 blinded observers each assessed the images for the presence and absence of VRFs 2 times separated by a 1-week interval. P-values<0.05 were considered to indicate significance. Results: Of the 4 protocols, unfilled teeth analysed with the MAR algorithm had the highest accuracy of incomplete VRF diagnosis (0.65), while unfilled teeth reviewed without MAR were associated with the least accurate diagnosis (0.55). With MAR, an unfilled tooth with an incomplete VRF was 4 times more likely to be identified as having an incomplete VRF than an unfilled tooth without this condition, while without MAR, an unfilled tooth with an incomplete VRF was 2.28 times more likely to be identified as having an incomplete VRF than an unfilled tooth without this condition. Conclusion: The use of the MAR algorithm increased the diagnostic accuracy in the detection of incomplete VRF on images of unfilled teeth.

15.
J Clin Exp Dent ; 15(3): e233-e238, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37008240

RESUMO

Background: The ability of the Reciproc system (R40) followed by continuous ultrasonic irrigation (CUI) to remove filling material from oval root canals of mandibular premolars filled with gutta-percha and AH Plus or Bio-C Sealer was evaluated by microtomography (micro-CT). Material and Methods: The straight and oval root canals of 42 mandibular premolars were prepared with the ProDesign R 35.05 reciprocal file and randomly divided into two groups according to the material used to fill the canals (n=21): Group AH - Master Cone and AH Plus; Group BC - Master Cone and Bio-C Sealer. After filling and provisional sealing, the teeth were stored at 100% relative humidity and a temperature of 37°C for 30 days. The filling material was then removed with an R40 file. The material was considered completely removed when the R40 file reached the working length (WL), and no remaining filling material was visible on the canal walls. CUI was then performed. The teeth were scanned by micro- CT before and after removal of the filling material. The remaining filling material was measured in mm in the last apical 5 mm. The data were analyzed with the nonparametric Friedman test and subsequently with the Dunn test. The Mann-Whitney U test was also performed. Statistical significance was accepted at the 5% level. Results: After instrumentation with the Reciproc R40, the volume of residual filling material was significantly greater in the BC group than in the AH group (P = 0.035). After CUI, there was no difference in the volume of residual material between the two groups (P = 0.705). Conclusions: Bio-C sealer was more difficult to remove with the Reciproc file than AH Plus. CUI improved the removal of residual filling material regardless of sealer type. However, no technique was able to completely clear the canals of filling material. Key words:Bioceramic cement, CUI, micro-CT, reciproc, retreatment.

16.
Restor Dent Endod ; 48(1): e4, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36875808

RESUMO

Objectives: This study aimed to compare the torsional and cyclic fatigue resistance of ProGlider (PG), WaveOne Gold Glider (WGG), and TruNatomy Glider (TNG). Materials and Methods: A total of 15 instruments of each glide path system (n = 15) were used for each test. A custom-made device simulating an angle of 90° and a radius of 5 millimeters was used to assess cyclic fatigue resistance, with calculation of number of cycles to failure. Torsional fatigue resistance was assessed by maximum torque and angle of rotation. Fractured instruments were examined by scanning electron microscopy (SEM). Data were analyzed with Shapiro-Wilk and Kruskal-Wallis tests, and the significance level was set at 5%. Results: The WGG group showed greater cyclic fatigue resistance than the PG and TNG groups (p < 0.05). In the torsional fatigue test, the TNG group showed a higher angle of rotation, followed by the PG and WGG groups (p < 0.05). The TNG group was superior to the PG group in torsional resistance (p < 0.05). SEM analysis revealed ductile morphology, typical of the 2 fracture modes: cyclic fatigue and torsional fatigue. Conclusions: Reciprocating WGG instruments showed greater cyclic fatigue resistance, while TNG instruments were better in torsional fatigue resistance. The significance of these findings lies in the identification of the instruments' clinical applicability to guide the choice of the most appropriate instrument and enable the clinician to provide a more predictable glide path preparation.

17.
Eur J Dent ; 17(3): 699-705, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36220114

RESUMO

OBJECTIVE: This study compared the shaping ability of the Hyflex CM and XP-endo Shaper rotary file systems in curved mesial canals of mandibular molars using micro-computed tomography. MATERIAL AND METHODS: Seventeen mesial roots of extracted first mandibular molars with two independent mesial canals were scanned before and after root canal preparation with the tested rotatory file systems. Each mesial canal from the same specimen was prepared with one of the two systems. The parameters analyzed were canal centering (transportation) for the cervical, middle, and apical segments, as well as for the entire canal (0-10 mm from the apex); and canal volume increase, canal surface area increase, and unprepared canal walls for two segments, 0 to 4 mm and 0 to 10 mm from the apex. RESULTS: There was no significant difference between both systems regarding canal centering (transportation), volume increase, and unprepared canal walls for the 0 to 10 mm segment (p> 0.05); however, a significant difference was observed for the 0 to 4 mm segment (p <0.01), where the Hyflex CM left 28.46% of unprepared walls and XP-endo Shaper left 13.26%. CONCLUSIONS: The shaping ability of the two tested rotatory file systems in mesial roots of first mandibular molars was similar for all parameters in all the segments evaluated, except for the 0 to 4 mm segment, where XP-endo Shaper left a smaller area of unprepared canal walls than Hyflex CM.

18.
Aust Endod J ; 49 Suppl 1: 18-26, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36093994

RESUMO

The aim of this study was to evaluate the maximum penetration depth (MPD) and penetration area (PA) of CaOH2 paste agitated by different methods and to measure the pH after performing these methods. Fifty-five mandibular premolars were divided into control, GL and 4 experimental groups, GEC, GXP, GEDDY and GI (n = 11), where the paste was agitated with Easy Clean, XP-endo Finisher, EDDY and Irrisonic, respectively. The canals were instrumented and irrigated with NaOCl. The paste was manipulated with propylene glycol and rhodamine B dye. Root sections were examined using confocal laser scanning microscopy. There was no difference between groups regarding PA (p > 0.05). At 5 mm, MPD was greater in GEC than in GL or GEDDY, and greater in GI than in GL (p < 0.05). At 2 mm, MPD was greater in GEC than in the other groups (p < 0.05). In conclusion, both Easy Clean and Irrisonic promoted deeper paste penetration and were associated with higher pH levels.


Assuntos
Propilenoglicol , Irrigantes do Canal Radicular , Irrigantes do Canal Radicular/farmacologia , Microscopia Confocal , Dente Pré-Molar , Cavidade Pulpar , Preparo de Canal Radicular/métodos
19.
Eur J Dent ; 17(2): 472-477, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36195211

RESUMO

OBJECTIVE: The aim of this study was to compare the cyclic fatigue of heat-treated and non-treated instruments. MATERIALS AND METHODS: Twenty instruments with and without heat treatment from Bassi Logic were evaluated (n = 10). All instruments were subjected to dynamic cyclic fatigue through continuous rotations inside a stainless-steel tube (1.4-mm diameter, 9-mm curvature with 6-mm radius, and 90° angle) using a custom-made device, which performed 1 axial oscillation every 2 seconds with an amplitude of 3 mm, powered by a torque-controlled motor (Silver Reciproc, VDW, Germany), with speed adjusting to 950 rpm and torque to 4 N, according to manufacturer's guidance. The groups were compared using the Mann-Whitney test. RESULT: The fracture time of the heat-treated instruments (97.20 ± 39.94 second and non-treated instruments (14.30 ± 6.78 seconds had statistical differences [p < 0.05]). Heat-treated instruments were 6.8 times more resistant to fatigue than non-treated instruments (p < 0.05). CONCLUSION: Heat treatment provides increased fatigue resistance of NiTi alloy with the same design.

20.
Eur J Dent ; 16(3): 663-668, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35016238

RESUMO

OBJECTIVE: This study compared the ProTaper Next (PTN; Dentsply Sirona, Tulsa, Oklahoma, United States) and HyFlex EDM (HEDM; Coltene/Whaledent AG, Alstätten, Switzerland) systems using micro-computed tomography (CT). MATERIALS AND METHODS: Twenty-one mesial roots classified as Vertucci's type IV from extracted mandibular first molars with curvatures between 20 and 40 degrees were selected. The teeth were scanned using a micro-CT before and after root canal preparation by both systems, applied to the same root, in alternating canals. The following parameters were analyzed: canal centering, apical transportation, root canal diameter/root diameter. RESULTS: No statistically significant differences between both systems were observed for any of the assessed morphological parameters (p > 0.05). All canals presented diameter enlargement of more than 40% in relation to root diameter in the cervical and middle segments. No statistically significant difference was noted between the HEDM and PTN groups. The wear percentage for the HEDM group in the cervical and middle thirds were 49.66 ± 8.65 and 46.48 ± 14.29, respectively, and 51.02 ± 11.81 and 45.48 ± 10.79 for the PTN group, respectively. CONCLUSION: Both systems displayed similar mandibular molar mesial canals preparation, with no differences noted for any of the assessed parameters. Both groups showed increased canal diameter in the cervical and middle thirds by more than 40%.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...