Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Orthop Res ; 42(2): 385-394, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37525546

RESUMO

Cam femoroacetabular impingement (FAI) syndrome is associated with hip osteoarthritis (OA) development. Hip shape features, derived from statistical shape modeling (SSM), are predictive for OA incidence, progression, and arthroplasty. Currently, no three-dimensional (3D) SSM studies have investigated whether there are cam shape differences between male and female patients, which may be of potential clinical relevance for FAI syndrome assessments. This study analyzed sex-specific cam location and shape in FAI syndrome patients from clinical magnetic resonance examinations (M:F 56:41, age: 16-63 years) using 3D focused shape modeling-based segmentation (CamMorph) and partial least squares regression to obtain shape features (latent variables [LVs]) of cam morphology. Two-way analysis of variance tests were used to assess cam LV data for sex and cam volume severity differences. There was no significant interaction between sex and cam volume severity for the LV data. A sex main effect was significant for LV 1 (cam size) and LV 2 (cam location) with medium to large effect sizes (p < 0.001, d > 0.75). Mean results revealed males presented with a superior-focused cam, whereas females presented with an anterior-focused cam. When stratified by cam volume, cam morphologies were located superiorly in male and anteriorly in female FAI syndrome patients with negligible, mild, or moderate cam volumes. Both male and female FAI syndrome patients with major cam volumes had a global cam distribution. In conclusion, sex-specific cam location differences are present in FAI syndrome patients with negligible, mild, and moderate cam volumes, whereas major cam volumes were globally distributed in both male and female patients.


Assuntos
Impacto Femoroacetabular , Osteoartrite do Quadril , Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Impacto Femoroacetabular/cirurgia , Imageamento por Ressonância Magnética , Imageamento Tridimensional/métodos , Articulação do Quadril/patologia
3.
Phys Eng Sci Med ; 46(4): 1791-1802, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37819450

RESUMO

Combined magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) may enhance diagnosis, aid surgical planning and intra-operative orientation for prostate biopsy and radical prostatectomy. Although PET-MRI may provide these benefits, PET-MRI machines are not widely available. Image fusion of Prostate specific membrane antigen PET/CT and MRI acquired separately may be a suitable clinical alternative. This study compares CT-MR registration algorithms for urological prostate cancer care. Paired whole-pelvis MR and CT scan data were used (n = 20). A manual prostate CTV contour was performed independently on each patients MR and CT image. A semi-automated rigid-, automated rigid- and automated non-rigid registration technique was applied to align the MR and CT data. Dice Similarity Index (DSI), 95% Hausdorff distance (95%HD) and average surface distance (ASD) measures were used to assess the closeness of the manual and registered contours. The automated non-rigid approach had a significantly improved performance compared to the automated rigid- and semi-automated rigid-registration, having better average scores and decreased spread for the DSI, 95%HD and ASD (all p < 0.001). Additionally, the automated rigid approach had similar significantly improved performance compared to the semi-automated rigid registration across all accuracy metrics observed (all p < 0.001). Overall, all registration techniques studied here demonstrated sufficient accuracy for exploring their clinical use. While the fully automated non-rigid registration algorithm in the present study provided the most accurate registration, the semi-automated rigid registration is a quick, feasible, and accessible method to perform image registration for prostate cancer care by urologists and radiation oncologists now.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Pelve
4.
Quant Imaging Med Surg ; 12(10): 4924-4941, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36185062

RESUMO

Background: Femoroacetabular impingement (FAI) cam morphology is routinely assessed using manual measurements of two-dimensional (2D) alpha angles which are prone to high rater variability and do not provide direct three-dimensional (3D) data on these osseous formations. We present CamMorph, a fully automated 3D pipeline for segmentation, statistical shape assessment and measurement of cam volume, surface area and height from clinical magnetic resonance (MR) images of the hip in FAI patients. Methods: The novel CamMorph pipeline involves two components: (I) accurate proximal femur segmentation generated by combining the 3D U-net to identify both global (region) and local (edge) features in clinical MR images and focused shape modelling to generate a 3D anatomical model for creating patient-specific proximal femur models; (II) patient-specific anatomical information from 3D focused shape modelling to simulate 'healthy' femoral bone models with cam-affected region constraints applied to the anterosuperior femoral head-neck region to quantify cam morphology in FAI patients. The CamMorph pipeline, which generates patient-specific data within 5 min, was used to analyse multi-site clinical MR images of the hip to measure and assess cam morphology in male (n=56) and female (n=41) FAI patients. Results: There was excellent agreement between manual and CamMorph segmentations of the proximal femur as demonstrated by the mean Dice similarity index (DSI; 0.964±0.006), 95% Hausdorff distance (HD; 2.123±0.876 mm) and average surface distance (ASD; 0.539±0.189 mm) values. Compared to female FAI patients, male patients had a significantly larger median cam volume (969.22 vs. 272.97 mm3, U=240.0, P<0.001), mean surface area [657.36 vs. 306.93 mm2, t(95)=8.79, P<0.001], median maximum-height (3.66 vs. 2.15 mm, U=407.0, P<0.001) and median average-height (1.70 vs. 0.86 mm, U=380.0, P<0.001). Conclusions: The fully automated 3D CamMorph pipeline developed in the present study successfully segmented and measured cam morphology from clinical MR images of the hip in male and female patients with differing FAI severity and pathoanatomical characteristics.

5.
Arthrosc Sports Med Rehabil ; 4(4): e1353-e1362, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36033193

RESUMO

Purpose: To obtain automated measurements of cam volume, surface area, and height from baseline (preintervention) and 12-month magnetic resonance (MR) images acquired from male and female patients allocated to physiotherapy (PT) or arthroscopic surgery (AS) management for femoroacetabular impingement (FAI) in the Australian FASHIoN trial. Methods: An automated segmentation pipeline (CamMorph) was used to obtain cam morphology data from three-dimensional (3D) MR hip examinations in FAI patients classified with mild, moderate, or major cam volumes. Pairwise comparisons between baseline and 12-month cam volume, surface area, and height data were performed within the PT and AS patient groups using paired t-tests or Wilcoxon signed-rank tests. Results: A total of 43 patients were included with 15 PT patients (9 males, 6 females) and 28 AS patients (18 males, 10 females) for premanagement and postmanagement cam morphology assessments. Within the PT male and female patient groups, there were no significant differences between baseline and 12-month mean cam volume (male: 1269 vs 1288 mm3, t[16] = -0.39; female: 545 vs 550 mm,3 t[10] = -0.78), surface area (male: 1525 vs 1491 mm2, t[16] = 0.92; female: 885 vs 925 mm,2 t[10] = -0.78), maximum height (male: 4.36 vs 4.32 mm, t[16] = 0.34; female: 3.05 vs 2.96 mm, t[10] = 1.05) and average height (male: 2.18 vs 2.18 mm, t[16] = 0.22; female: 1.4 vs 1.43 mm, t[10] = -0.38). In contrast, within the AS male and female patient groups, there were significant differences between baseline and 12-month cam volume (male: 1343 vs 718 mm3, W = 0.0; female: 499 vs 240 mm3, t[18] = 2.89), surface area (male: 1520 vs 1031 mm2, t(34) = 6.48; female: 782 vs 483 mm2, t(18) = 3.02), maximum-height (male: 4.3 vs 3.42 mm, W = 13.5; female: 2.85 vs 2.24 mm, t(18) = 3.04) and average height (male: 2.17 vs 1.52 mm, W = 3.0; female: 1.4 vs 0.94 mm, W = 3.0). In AS patients, 3D bone models provided good visualization of cam bone mass removal postostectomy. Conclusions: Automated measurement of cam morphology from baseline (preintervention) and 12-month MR images demonstrated that the cam volume, surface area, maximum-height, and average height were significantly smaller in AS patients following ostectomy, whereas there were no significant differences in these cam measures in PT patients from the Australian FASHIoN study. Level of Evidence: Level II, cohort study.

6.
Exp Gerontol ; 156: 111594, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34673171

RESUMO

With aging comes reductions in the quality and size of skeletal muscle. These changes influence the force-generating capacity of skeletal muscle and contribute to movement deficits that accompany aging. Although declines in strength remain a significant barrier to mobility in older adults, the association between age-related changes in muscle structure and function remain unresolved. In this study, we compared age-related differences in (i) muscle volume and architecture, (ii) the quantity and distribution of intramuscular fat, and (iii) muscle shear modulus (an index of stiffness) in the triceps surae in 21 younger (24.6 ± 4.3 years) and 15 older (70.4 ± 2.4 years) healthy adults. Additionally, we explored the relationship between muscle volume, architecture, intramuscular fat and ankle plantar flexion strength in young and older adults. Magnetic resonance imaging was used to determine muscle volume and intramuscular fat content. B-mode ultrasound was used to quantify muscle architecture, shear-wave elastography was used to measure shear modulus, and ankle strength was measured during maximal isometric plantar flexion contractions. We found that older adults displayed higher levels of intramuscular fat yet similar muscle volumes in the medial (MG) and lateral gastrocnemius (LG) and soleus, compared to younger adults. These age-related higher levels of intramuscular fat were associated with lower muscle shear modulus in the LG and MG. We also found that muscle physiological cross-sectional area (PCSA) that accounted for age-associated differences in intramuscular fat showed a modest increase in its association with ankle strength compared to PCSA that did not account for fat content. This highlights that skeletal muscle fat infiltration plays a role in age-related strength deficits, but does not fully explain the age-related loss in muscle strength, suggesting that other factors play a more significant role.


Assuntos
Contração Isométrica , Músculo Esquelético , Idoso , Articulação do Tornozelo/fisiologia , Humanos , Contração Isométrica/fisiologia , Perna (Membro) , Força Muscular/fisiologia , Músculo Esquelético/fisiologia
7.
Magn Reson Imaging ; 82: 42-54, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34147595

RESUMO

BACKGROUND: Magnetic resonance (MR) T2 and T2* mapping sequences allow in vivo quantification of biochemical characteristics within joint cartilage of relevance to clinical assessment of conditions such as hip osteoarthritis (OA). PURPOSE: To evaluate an automated immediate reliability analysis of T2 and T2* mapping from MR examinations of hip joint cartilage using a bone and cartilage segmentation pipeline based around focused shape modelling. STUDY TYPE: Technical validation. SUBJECTS: 17 asymptomatic volunteers (M: F 7:10, aged 22-47 years, mass 50-90 kg, height 163-189 cm) underwent unilateral hip joint MR examinations. Automated analysis of cartilage T2 and T2* data immediate reliability was evaluated in 9 subjects (M: F 4: 5) for each sequence. FIELD STRENGTH/SEQUENCE: A 3 T MR system with a body matrix flex-coil was used to acquire images with the following sequences: T2 weighted 3D-trueFast Imaging with Steady-State Precession (water excitation; 10.18 ms repetition time (TR); 4.3 ms echo time (TE); Voxel Size (VS): 0.625 × 0.625 × 0.65 mm; 160 mm field of view (FOV); Flip Angle (FA): 30 degrees; Pixel Bandwidth (PB): 140 Hz/pixel); a multi-echo spin echo (MESE) T2 mapping sequence (TR/TE: 2080/18-90 ms (5 echoes); VS: 4 × 0.78 × 0.78 mm; FOV: 200 mm; FA: 180 degrees; PB: 230 Hz/pixel) and a MESE T2* mapping sequence (TR/TE: 873/3.82-19.1 ms (5 echoes); VS: 3 × 0.625 × 0.625 mm; FOV: 160 mm; FA: 25 degrees; PB: 250 Hz/pixel). ASSESSMENT: Automated cartilage segmentation and quantitative analysis provided T2 and T2* data from test-retest MR examinations to assess immediate reliability. STATISTICAL TESTS: Coefficient of variation (CV) and intraclass correlations (ICC2, 1) to analyse automated T2 and T2* mapping reliability focusing on the clinically important superior cartilage regions of the hip joint. RESULTS: Comparisons between test-retest T2 and (T2*) data revealed mean CV's of 3.385% (1.25%), mean ICC2, 1's of 0.871 (0.984) and median mean differences of -1.139ms (+0.195ms). CONCLUSION: The T2 and T2* times from automated analyses of hip cartilage from test-retest MR examinations had high (T2) and excellent (T2*) immediate reliability.


Assuntos
Cartilagem Articular , Imageamento por Ressonância Magnética , Cartilagem Articular/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...