Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Small Methods ; : e2400094, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426646

RESUMO

Recent developments in the synthesis of hybrid organic-inorganic halide perovskite quantum dots (HP-QDs) through compositional adjustments have highlighted their potential applications in the fields of photovoltaics and light sources due to their unique optoelectronic properties. However, traditional methods to fine-tune their composition involve repetitive, labor-intensive, and costly processes. Herein, the utilization of a continuous flow chemistry approach is developed, in combination with a Proportional-Integral (PI) feedback control system as an effective method for producing on-demand methylammonium lead bromoiodide (MAPbBrx I3-x ) HP-QDs. The PI feedback control allows for real-time optimization of the flow rates of halide precursor solutions (halide PSs), enabling the precise tuning of the emission wavelength of HP-QDs. HP-QDs having an emission wavelength of 550 and 650 nm are synthesized through a blue-shifted and red-shifted algorithm, respectively, from any arbitrary reaction condition within 400 s. The iterative process through the PI feedback control produces the target HP-QDs with short rise time and low overshoot. The proposed automatic flow chemistry system integrated with a universal and accessible control algorithm of PI can generate the target HP-QDs with high accuracy, stability, and robustness, demonstrating a significant advancement in constructing an autonomous flow chemistry synthetic system.

2.
ACS Sens ; 8(2): 515-521, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36722714

RESUMO

We proposed a portable sample pretreatment microsystem, which can be automatically operated through speech recognition in a smartphone app. The proposed sample pretreatment microsystem consists of a microfluidic chip, an air router, pressure and vacuum lines with air pump motors, six 3-way solenoid valves, and a microcontroller with a Bluetooth module. The command of a human voice conducted the whole process of DNA extraction from pathogenic bacterial samples. Thus, manual interference during the DNA extraction is eliminated, preventing any potential infection from human touch. The palm-sized sample pretreatment microsystem can be run by a portable battery or a conventional smartphone charger. Genomic DNA ofSalmonella typhimuriumwas purified on a chip in less than 1 min with an extraction efficiency of 70 ± 5%.


Assuntos
Aplicativos Móveis , Percepção da Fala , Humanos , Microfluídica , Smartphone , DNA/genética
3.
Biosens Bioelectron ; 195: 113655, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34571479

RESUMO

Rapid and accurate testing tools for SARS-CoV-2 detection are urgently needed to prevent the spreading of the virus and to take timely governmental actions. Internet of things (IoT)-based diagnostic devices would be an ideal platform for point-of-care (POC) screening of COVID-19 and ubiquitous healthcare monitoring for patients. Herein, we present an advanced IoT-based POC device for real-time direct reverse-transcription-loop mediated isothermal amplification assay to detect SARS-CoV-2. The diagnostic system is miniaturized (10 cm [height] × 9 cm [width] × 5.5 cm [length]) and lightweight (320 g), which can be operated with a portable battery and a smartphone. Once a liquid sample was loaded into an integrated microfluidic chip, a series of sample lysis, nucleic amplification, and real-time monitoring of the fluorescent signals of amplicons were automatically performed. Four reaction chambers were patterned on the chip, targeting As1e, N, E genes and a negative control, so multiple genes of SARS-CoV-2 could be simultaneously analyzed. The fluorescence intensities in each chamber were measured by a CMOS camera upon excitation with a 488 nm LED light source. The recorded data were processed by a microprocessor inside the IoT-based POC device and transferred and displayed on the wirelessly connected smartphone in real-time. The positive results could be obtained using three primer sets of SARS-CoV-2 with a limit of detection of 2 × 101 genome copies/µL, and the clinical sample of SARS-CoV-2 was successfully analyzed with high sensitivity and accuracy. Our platform could provide an advanced molecular diagnostic tool to test SARS-CoV-2 anytime and anywhere.


Assuntos
Técnicas Biossensoriais , COVID-19 , Internet das Coisas , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Sistemas Automatizados de Assistência Junto ao Leito , RNA Viral , SARS-CoV-2 , Sensibilidade e Especificidade
4.
Electrophoresis ; 41(5-6): 306-310, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31785603

RESUMO

A novel microfluidic droplet generator is proposed, which can control the droplet size through turning an integrated micrometer head with ease, and the size of the produced micro-droplet can be automatically and real-time monitored by an open-sourced software and off-the-shelf hardware.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Desenho de Equipamento , Tamanho da Partícula , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...