Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Obstet Gynecol ; 136(5): 876-881, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33030862

RESUMO

BACKGROUND: Postpartum hemorrhage is a leading cause of maternal mortality globally. A tamponade agent that can be quickly and easily placed in a range of settings could advance the treatment of atonic hemorrhage. METHOD: We adapted a highly effective trauma dressing for use in postpartum hemorrhage. This mini-sponge tamponade device is comprised of two components: compressed mini-sponges contained within a strong mesh pouch and a tubular applicator. Compressed mini-sponges rapidly absorb blood, expand within seconds, and exert sustained pressure uniformly to bleeding sites. The sponges are deployed within a mesh pouch to facilitate simple vaginal removal. EXPERIENCE: We successfully placed the mini-sponge device in nine patients experiencing postpartum hemorrhage after vaginal birth, with resolution of bleeding within 1 minute. The mean time to place the device was 62 seconds. Uterine fill was documented in all cases by ultrasound scan, and device placement was rated as "easy" to "very easy." Mini-sponges were left in place on average for 1 hour (0.5 hours-14 hours). Bleeding did not recur. There were no adverse events; all patients remained afebrile and did not require subsequent surgical intervention. CONCLUSION: This study supports further evaluation of the mini-sponge device for the management of postpartum hemorrhage. FUNDING: This study was funded by OBSTETRX, Inc.


Assuntos
Hemorragia Pós-Parto/terapia , Tampões de Gaze Cirúrgicos , Tamponamento com Balão Uterino/instrumentação , Adulto , Dispositivos Anticoncepcionais Femininos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Gravidez , Resultado do Tratamento , Tamponamento com Balão Uterino/métodos , Vagina , Adulto Jovem
2.
BMC Pregnancy Childbirth ; 17(1): 187, 2017 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-28610569

RESUMO

BACKGROUND: Although uterine tamponade is an effective treatment for postpartum hemorrhage (PPH), current methods have key limitations in their use, particularly in low resource settings. The XStat™ Mini Sponge Dressing (MSD) is approved for the management of non-compressible wounds in the battlefield/trauma setting. The MSD applies highly compressed medical sponges capable of stopping high-flow arterial bleeding within seconds. The objective of our study was to adopt the MSD for use in managing PPH. METHODS: We performed desktop testing using a uterine model with pressure sensors to compare key design elements of the obstetrical prototype MSD (fundal pressure achieved, reduction in fluid loss, time to deploy, and time to remove) with alternativetechniques (uterine packing, balloon tamponade). To evaluate safety, we delivered the fetus of pregnant ewes by cesarean section and used the prototype to deliver the MSD into one uterine horn, and closed the hysterotomy. We followed the clinical recovery of animals (n = 3) over 24 h, and then removed the reproductive tract for histologic evaluation. To evaluate late effects, we surgically removed the MSDs after 24 h, and followed the clinical recovery of animals (n = 6) for an additional seven days before tissue removal. RESULTS: The obstetrical prototype has a long tapered delivery system designed to be deployed during vaginal examination, and administers three times the volume of the approved MSD trauma bandage. The MSD are deployed within a mesh bag to facilitate removal by vaginaltraction. On desktop testing, the MSD resulted in the highest average fundal pressure (113 mmHg), followed by the MSD bag device (85.8 mmHg), gauze packing (15.5 mmHg), and the uterine balloon (8.2 mmHg). The MSD bag test group achieved the largest fluid flow reduction of -74%, followed by gauze packing (-55%), MSD (-35%), and uterine balloon (-19%). Animal testing demonstrated good uterine fill with no evidence of adverse clinical recovery, uterine trauma or infection at 24 h, or up to 7 days following device removal. CONCLUSION: We adapted a highly effective trauma dressing and applicator for use in the treatment of severe PPH. Preliminary desktop and animal testing provide a basis for initial clinical trials in women.


Assuntos
Obstetrícia/instrumentação , Tampões de Gaze Cirúrgicos , Animais , Bandagens , Remoção de Dispositivo , Modelos Animais de Doenças , Desenho de Equipamento , Feminino , Obstetrícia/métodos , Hemorragia Pós-Parto/terapia , Gravidez , Ovinos , Tampões de Gaze Cirúrgicos/efeitos adversos , Transdutores de Pressão , Tamponamento com Balão Uterino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...