Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Gen Intern Med ; 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39060786

RESUMO

BACKGROUND AND AIMS: Severity of fibrosis is the driver of liver-related outcomes in metabolic dysfunction-associated steatotic liver disease (MASLD), and non-invasive testing such as fibrosis-4 (FIB-4) score is utilized for risk stratification. We aimed to determine if primary care patients at risk for MASLD and advanced fibrosis were evaluated with subsequent testing. A secondary aim was to determine if at-risk patients with normal aminotransferases had advanced fibrosis. METHODS: Primary care patients at increased risk for MASLD with advanced fibrosis (n = 91,914) were identified using previously established criteria. Patients with known alternative/concomitant etiology of liver disease or cirrhosis were excluded. The study cohort included patients with calculated FIB-4 score in 2020 (n = 52,006), and stratified into low, indeterminate, and high likelihood of advanced fibrosis. Among those at indeterminate/high risk, rates of subsequent testing were measured. RESULTS: Risk stratification with FIB-4 characterized 77% (n = 40,026) as low risk, 17% (n = 8847) as indeterminate, and 6% (n = 3133) as high risk. Among indeterminate/high-risk patients (n = 11,980), 78.7% (n = 9433) had aminotransferases within normal limits, 0.95% (n = 114) had elastography, and 8.2% (n = 984) were referred for subspecialty evaluation. CONCLUSION: In this cohort of primary care patients at risk for MASLD with fibrosis, the FIB-4 score identified a substantial proportion of indeterminate/high-risk patients, the majority of which had normal aminotransferase levels. Low rates of subsequent testing were observed. These data suggest that a majority of patients at increased risk for liver-related outcomes remain unrecognized and highlight opportunities to facilitate their identification.

2.
CVIR Endovasc ; 3(1): 69, 2020 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-32960372

RESUMO

PURPOSE: To quantify and categorize fluoroscopically-guided procedures with radiation doses exceeding 5000 mGy reference point air kerma (Ka,r). Ka,r > 5000 mGy has been defined as a "significant radiation dose" by the Society of Interventional Radiology. Identification and analysis of interventions with high radiation doses has the potential to reduce radiation-induced injuries. MATERIALS AND METHODS: Radiation dose data from a dose monitoring system for 19 interventional suites and 89,549 consecutive patient encounters from January 1, 2013 to August 1, 2019 at a single academic institution were reviewed. All patient encounters with Ka,r > 5000 mGy were included. All other encounters were excluded (n = 89,289). Patient demographics, medical specialty, intervention type, fluoroscopy time (minutes), dose area product (mGy·cm2), and Ka,r (mGy) were evaluated. RESULTS: There were 260 (0.3%) fluoroscopically-guided procedures with Ka,r > 5000 mGy. Of the 260 procedures which exceeded 5000 mGy, neurosurgery performed 81 (30.5%) procedures, followed by interventional radiology (n = 75; 28.2%), neurointerventional radiology (n = 55; 20.7%), and vascular surgery (n = 49; 18.4%). The procedures associated with the highest Ka,r were venous stent reconstruction performed by interventional radiology, arteriovenous malformation embolization performed by neurointerventional radiology, spinal hardware fixation by neurosurgery, and arterial interventions performed by vascular surgery. Neurointerventional radiology had the highest mean Ka,r (7,799 mGy), followed by neurosurgery (7452 mGy), vascular surgery (6849 mGy), and interventional radiology (6109 mGy). The mean Ka,r for interventional radiology performed procedures exceeding 5000 mGy was significantly lower than that for neurointerventional radiology, neurosurgery, and vascular surgery. CONCLUSIONS: Fluoroscopically-guided procedures with radiation dose exceeding 5000 mGy reference point air kerma are uncommon. The results of this study demonstrate that a large proportion of cases exceeding 5000 mGy were performed by non-radiologists, who likely do not receive the same training in radiation physics, radiation biology, and dose reduction techniques as radiologists.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...