Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Med (Hagerstown) ; 10(11): 834-41, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19521255

RESUMO

BACKGROUND: To evaluate the safety, reproducibility and pitfalls of an aortic valve re-implantation (AVRei) technique. METHODS: From June 2005 to December 2008, 30 patients underwent aortic valve-sparing re-implantation with Gelweave Valsalva prosthesis. Mean age was 66 +/- 7 years (range 47-81). Mean aortic root diameter was 49 +/- 6 mm (range 37-70) and 12 patients had an aortic insufficiency more than 2+. All the patients were elective, except three who underwent surgery for type A aortic dissection. Two patients had Marfan syndrome and one had a bicuspid aortic valve. Isolated aortic root replacement was performed in 26 patients, whereas hemiarch extension was required in four. All the survivors underwent serial echocardiographic assessment for functional results and multi-detector computed tomography (MDCT) for aortic root morphology evaluation. RESULTS: There was one early death and one re-exploration for bleeding. Two patients suffered from a perioperative stroke and four required a pacemaker implantation because of a complete atrio-ventricular block. Mean follow-up was 12 +/- 10 months (range 1-42) with no late deaths, whereas freedom from reoperation was 100% and freedom from aortic insufficiency 2+ or more was 96.5%. MDCT aortic root reconstruction showed a pseudo-normalization of the neo-sinuses of Valsalva mimicking the human normal aortic root morphology. CONCLUSION: AVRei with Valsalva conduit is a well-tolerated procedure both in elective and emergency situations. In well-selected patients, good functional and clinical results can be achieved, regardless of the cause of the aortic root disease. Application of simple surgical manoeuvres allows durable clinical efficacy to be obtained without the risk of major complications.


Assuntos
Aneurisma Aórtico/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Reimplante , Seio Aórtico/cirurgia , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Dissecção Aórtica/cirurgia , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Síndrome de Marfan/complicações , Síndrome de Marfan/cirurgia , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Seio Aórtico/diagnóstico por imagem , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...