Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Glaucoma ; 6(3): 152-6, 1997 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9211137

RESUMO

PURPOSE: To examine the management and possible causes of primary valve malfunction of the Krupin eye valve with disk. METHODS: The authors reviewed the results of 113 patients undergoing implantation of the Krupin eye valve with disk and identified eight patients with primary valve malfunction requiring surgical revision. RESULTS: Valve revision involved manipulation (n = 1 case), explantation of the malfunctioning valve and implantation of a new valve (n = 2), and amputation of the valve (n = 5). Six of eight patients had final intraocular pressures of < 21 mmHg on one or no medications at a mean interval of 15.9 months (range 5-36) after surgical revision. Transient postoperative hypotony was noted in three patients and chronic hypotony with loss of light perception in one patient. One explanted valve was examined and found to have partially fused leaflets. CONCLUSIONS: Surgical revision in cases of primary valve malfunction of the Krupin eye valve with disk may be accomplished relatively safely with an acceptable level of postoperative complications. The etiology of primary valve malfunction may be related to the sterilization process and prolonged storage before implantation.


Assuntos
Cirurgia Filtrante , Complicações Pós-Operatórias , Próteses e Implantes/efeitos adversos , Falha de Prótese , Seguimentos , Glaucoma/cirurgia , Humanos , Pressão Intraocular , Hipotensão Ocular/etiologia , Hipotensão Ocular/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Reoperação , Estudos Retrospectivos
3.
Curr Eye Res ; 14(4): 255-61, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7606912

RESUMO

Transscleral neodymium:yttrium-aluminum-garnet (Nd:YAG) laser cyclophotocoagulation (TSNYC) is used to lower intraocular pressure (IOP) in glaucoma patients refractory to conventional medical and surgical therapy. Our study investigates the ability of TSNYC to lower IOP in normal cats. One eye of 13 cats was treated with non-contact TSNYC. Mean pretreatment IOP was 25 mm Hg (vs. 25.3 mm Hg in contralateral control eyes). Eyes received 80 laser applications over 360 degrees delivered at least 3 mm posterior to the limbus with maximum power (8 to 9 joules) and maximum retrofocus (3.6 mm). Eyes were retreated if IOP was not reduced below baseline after 2 weeks. By 4 weeks, IOP was decreased in all treated eyes by a mean of 29.2% and was maintained as long as 20 weeks (mean decrease 14.8%). IOP in 10 eyes was lowered after a single treatment session. Of these, 2 eyes had IOP spikes > 10 mm Hg prior to IOP reduction. Three cats required retreatment to maintain IOP reduction. All eyes developed transient (< 4 weeks) postoperative uveitis and 3 eyes developed rubeosis iridis which resolved with topical corticosteroids. Histologic examination (6 weeks post-treatment) showed focal disruption of the pigment epithelium and to a lesser degree the nonpigmented epithelium at the base of the ciliary body and in the valleys of the pars ciliaris. The epithelium at the apices of the ciliary processes appeared intact. Vascular engorgement was variably present. This study demonstrates that TSNYC lowers IOP in cats. This animal model will be useful for investigating mechanism(s) responsible for TSNYC-induced IOP reduction.


Assuntos
Corpo Ciliar/cirurgia , Pressão Intraocular , Fotocoagulação a Laser , Hipotensão Ocular/etiologia , Animais , Gatos , Corpo Ciliar/patologia , Modelos Animais de Doenças , Glaucoma/cirurgia , Epitélio Pigmentado Ocular/patologia , Epitélio Pigmentado Ocular/cirurgia , Complicações Pós-Operatórias , Esclera
4.
J Glaucoma ; 4(3): 207-13, 1995 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19920671
5.
Br J Ophthalmol ; 74(5): 289-93, 1990 May.
Artigo em Inglês | MEDLINE | ID: mdl-2354137

RESUMO

The influence of stimulus size and normal database on the detection of visual field defects in automated static threshold perimetry (Humphrey Field Analyzer) was investigated in 82 eyes having a diagnosis of normal, glaucoma suspect, or early glaucoma. Using a mathematically derived 'normal' database, which assumes constantly decreasing threshold sensitivities with increasing eccentricity, the size I stimulus showed significantly greater sensitivity than the size III stimulus for detecting small, shallow scotomata in the central visual field. The use of Statpac, which contains an empirically derived, age-related normal database, increased the sensitivity significantly over that of the size III stimulus (with its mathematical model), and to a degree similar to that of the size I stimulus. The results obtained with the size I stimulus were reproducible and independent of the patient's age. This study suggests a potential role for the size I stimulus in evaluating eyes having or at risk of developing early glaucomatous field loss.


Assuntos
Glaucoma/fisiopatologia , Campos Visuais/fisiologia , Adulto , Humanos , Matemática , Pessoa de Meia-Idade , Modelos Biológicos , Limiar Sensorial/fisiologia , Testes de Campo Visual/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...