Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
SAGE Open Med Case Rep ; 8: 2050313X20953749, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32974027

RESUMO

An aberrant origin of the right subclavian artery arising as the most distal vessel from the aortic arch is an uncommon but clinically important anomaly. Its abnormal course may result in esophageal compression with dysphagia, or tracheal compression resulting in asthma or stridor, and can greatly complicate radial artery access for coronary angiography. When an aberrant right subclavian artery is obstructed by atherosclerotic plaque, it may produce symptoms of arm ischemia such as pain and weakness. For the past 75 years, the standard treatment approach for symptomatic aberrant right subclavian artery has been surgical correction. There are only three case reports of percutaneous therapy, all for nonocclusive stenosis. There are no reported cases of percutaneous treatment of a completely occluded aberrant right subclavian artery. We report a patient with exertional right arm heaviness and weakness who was found to have a 60-mm long aberrant right subclavian artery occlusion. The blockage was successfully treated with angioplasty and placement of a single stent using percutaneous vascular access. Chest computerized tomography and duplex ultrasonography 5 years after treatment demonstrated a patent stent. At 7-year follow-up, she remained symptom-free and had a normal radial pulse. This case represents the first report of total occlusion of aberrant right subclavian artery treated percutaneously. Long-term durability supports this as a viable alternative to surgery in appropriately selected patients.

2.
J Invasive Cardiol ; 32(5): 194-200, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32357131

RESUMO

OBJECTIVES: Endovascular therapy (EVT) has emerged as an alternative to surgery for the treatment of symptomatic infrarenal aortic stenosis (IAS). However, long-term outcomes with EVT are unknown. METHODS: We performed a retrospective review of patients with IAS treated with the endovascular approach at the University of Toledo Medical Center, Toledo, Ohio. We compared our single-center study (SCS) with a review of published studies (ROS) regarding complications, patency rate (PR), and repeat intervention rate (RIR). Pearson's Chi-square or Fisher's exact test, and the Student's t-test or Mann-Whitney U-test, were used for categorical and continuous variables, respectively. For the ROS data, we used a pooled mean of means. RESULTS: A total of 25 patients from the SCS were compared with 698 patients from the ROS data. Mean age was 63 years vs 58 years, females comprised 48% vs 54%, Rutherford class 3 comprised 68% vs 69%, and mean follow-up duration was 67 months vs 44 months in SCS vs ROS, respectively. PR at 12 months was 96% vs 90%, while PR at maximum time-period was 92% vs 76% in SCS vs ROS, respectively. RIR in SCS was 4% at 12 months and 8% at the maximum time period (20.2 years). RIR in ROS was 24% at the maximum time period (10 years). The mortality rate was 0% in the SCS arm vs 3.4% in the ROS arm. CONCLUSION: EVT is highly effective and safe, and was associated with excellent patency rates at long-term follow-up.


Assuntos
Doenças da Aorta , Procedimentos Endovasculares , Implante de Prótese Vascular , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ohio/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
3.
J Vasc Interv Radiol ; 27(11): 1650-1656.e1, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27542591

RESUMO

PURPOSE: To evaluate the safety and efficacy of a self-expanding bare-metal nitinol stent (Astron; BIOTRONIK AG, Bülach, Switzerland) for the treatment of atherosclerotic lesions in the common and external iliac arteries. This study tested the hypothesis that the major adverse event (MAE) rate at 12 months was less than or equal to a performance goal of 15%. MATERIALS AND METHODS: In a prospective study that began in November 2011, 161 patients with symptomatic iliac lesions were treated with an Astron stent in the United States, Canada, and Austria. The primary endpoint was a composite rate of procedure- and stent-related MAEs at 12 months that included 30-day mortality, clinically indicated target lesion revascularization (TLR), and index limb amputation. RESULTS: The MAE rate at 12 months was 2.1% (3/146; [95% CI: 0.4% to 5.9%]; p < 0.001). The acute procedural success and 30-day clinical success outcomes were both 95% (153/161). The primary patency rate at 12 months was 89.8% (115/128). The comparison of baseline and 12-month Ankle Brachial Index (ABI) measurements showed a mean increase of 0.23 ± 0.19 (p < 0.001). The Walking Impairment Questionnaire (WIQ) PAD specific score, walking distance score, walking speed score and stair climbing score paired each showed a significant increase from baseline to 12 months (p<0.001). CONCLUSIONS: The Astron stent system was shown to be safe and effective in the treatment of patients with atherosclerotic disease. The observed MAE rate met the pre-specified performance goal of 15%. The stent demonstrated a high 12-month primary patency rate and showed improvement in quality of life measures.


Assuntos
Ligas , Procedimentos Endovasculares/instrumentação , Artéria Ilíaca , Claudicação Intermitente/terapia , Doença Arterial Periférica/terapia , Stents Metálicos Autoexpansíveis , Idoso , Índice Tornozelo-Braço , Áustria , Canadá , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Teste de Esforço , Tolerância ao Exercício , Feminino , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Claudicação Intermitente/diagnóstico por imagem , Claudicação Intermitente/fisiopatologia , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Recuperação de Função Fisiológica , Sistema de Registros , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular , Caminhada
5.
Expert Rev Med Devices ; 12(2): 157-62, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25418344

RESUMO

Restenosis is one of the major limitations of the percutaneous treatment of peripheral artery disease, leading to the need for repeat interventions, limb loss and increased cost of therapy. The current standard of percutaneous treatment of stenotic lesions in the femoropopliteal arterial segment includes balloon angioplasty and bare-metal stenting. Recently, research in the field adapting the coronary arterial bed treatment model led to the inclusion of antimitotic drugs in the form of drug-eluting stents to combat neointimal proliferation and reduce the burden of restenosis. Randomized trial and registry data emerged indicating improved long-term outcomes with drug-eluting stents in peripheral arteries, lending the way to more widespread adaptation of this modality in the management of patients with peripheral artery disease.


Assuntos
Stents Farmacológicos , Artéria Femoral/patologia , Paclitaxel/uso terapêutico , Doença Arterial Periférica/tratamento farmacológico , Artéria Poplítea/patologia , Ensaios Clínicos como Assunto , Constrição Patológica , Stents Farmacológicos/economia , Artéria Femoral/efeitos dos fármacos , Humanos , Paclitaxel/economia , Paclitaxel/farmacologia , Artéria Poplítea/efeitos dos fármacos
6.
Cardiovasc Interv Ther ; 28(1): 98-100, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22875748

RESUMO

A 64 year old female underwent percutaneous coronary intervention (PCI) with stent placement through the femoral approach. On femoral angiography after the PCI, the arterial sheath insertion site was found to be in the inferior epigastric artery and not in the common femoral artery. We used an Angioseal vascular closure device for management and there were no access site complications.


Assuntos
Estenose Coronária/cirurgia , Artérias Epigástricas/diagnóstico por imagem , Artéria Femoral/diagnóstico por imagem , Intervenção Coronária Percutânea/métodos , Angiografia Coronária , Artérias Epigástricas/cirurgia , Feminino , Artéria Femoral/cirurgia , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
7.
Circ Cardiovasc Interv ; 4(5): 495-504, 2011 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21953370

RESUMO

BACKGROUND: Sustained benefits of drug-eluting stents in femoropopliteal arteries have not been demonstrated. This prospective, multinational, randomized study was designed to compare the 12-month safety and effectiveness of a polymer-free, paclitaxel-coated nitinol drug-eluting stent (DES) with percutaneous transluminal angioplasty (PTA) and provisional bare metal stent (BMS) placement in patients with femoropopliteal peripheral artery disease. METHODS AND RESULTS: Patients were randomly assigned to primary DES implantation (n=236) or PTA (n=238). Demographics and lesion characteristics were similar between groups (eg, average lesion length, approximately 65±40 mm). One hundred twenty patients had acute PTA failure and underwent secondary random assignment to provisional DES (n=61) or BMS (n=59). Primary end points were the 12-month rates of event-free survival and patency in the primary DES and PTA groups. Compared with the PTA group, the primary DES group exhibited superior 12-month event-free survival (90.4% versus 82.6%; P=0.004) and primary patency (83.1% versus 32.8%; P<0.001), satisfying the primary hypotheses. In the secondary evaluations, (1) the primary DES group exhibited superior clinical benefit compared with the PTA group (88.3% versus 75.8%; P<0.001), (2) the provisional DES group exhibited superior primary patency (89.9% versus 73.0%; P=0.01) and superior clinical benefit (90.5% and 72.3%, P=0.009) compared with the provisional BMS group, and (3) the stent fracture rate (both DES and BMS) was 0.9% (4/457). CONCLUSIONS: Femoropopliteal peripheral artery disease treatment with the paclitaxel-eluting stent was associated with superior 12-month outcomes compared with PTA and provisional BMS placement.


Assuntos
Angioplastia com Balão , Stents Farmacológicos , Artéria Femoral/patologia , Doença Arterial Periférica/terapia , Artéria Poplítea/patologia , Idoso , Implante de Prótese Vascular , Intervalo Livre de Doença , Stents Farmacológicos/estatística & dados numéricos , Feminino , Artéria Femoral/metabolismo , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Paclitaxel/efeitos adversos , Doença Arterial Periférica/patologia , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/metabolismo , Estudos Prospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
8.
Clin J Am Soc Nephrol ; 6(9): 2185-91, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21817131

RESUMO

BACKGROUND AND OBJECTIVES: Soluble CD40 ligand (sCD40L) is a marker of platelet activation; whether platelet activation occurs in the setting of renal artery stenosis and stenting is unknown. Additionally, the effect of embolic protection devices and glycoprotein IIb/IIIa inhibitors on platelet activation during renal artery intervention is unknown. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Plasma levels of sCD40L were measured in healthy controls, patients with atherosclerosis without renal stenosis, and patients with renal artery stenosis before, immediately after, and 24 hours after renal artery stenting. RESULTS: Soluble CD40L levels were higher in renal artery stenosis patients than normal controls (347.5 ± 27.0 versus 65.2 ± 1.4 pg/ml, P < 0.001), but were similar to patients with atherosclerosis without renal artery stenosis. Platelet-rich emboli were captured in 26% (9 of 35) of embolic protection device patients, and in these patients sCD40L was elevated before the procedure. Embolic protection device use was associated with a nonsignificant increase in sCD40L, whereas sCD40L declined with abciximab after the procedure (324.9 ± 42.5 versus 188.7 ± 31.0 pg/ml, P = 0.003) and at 24 hours. CONCLUSIONS: Atherosclerotic renal artery stenosis is associated with platelet activation, but this appears to be related to atherosclerosis, not renal artery stenosis specifically. Embolization of platelet-rich thrombi is common in renal artery stenting and is inhibited with abciximab.


Assuntos
Angioplastia , Aterosclerose/terapia , Ativação Plaquetária , Obstrução da Artéria Renal/terapia , Stents , Abciximab , Adulto , Anticorpos Monoclonais/uso terapêutico , Aterosclerose/sangue , Ligante de CD40/sangue , Feminino , Humanos , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Masculino , Pessoa de Meia-Idade , Obstrução da Artéria Renal/sangue
9.
Tech Vasc Interv Radiol ; 14(2): 75-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21550509

RESUMO

Distal embolization is a complication during lower-extremity revascularization procedures that may occur when intervening on acute or subacute lesions. Several studies have demonstrated the safety and feasibility of using embolic protection devices (EPD) and some interventionalists have adapted this technology for use in infrainguinal revascularization procedures. At present, there are no randomized trials to indicate the benefit, safety, and cost-effectiveness of EPD for this application and its use in the United States is considered off-label. However, based on our experience and a review of the published literature, we consider the use of EPD in acute lower-extremity ischemia a reasonable strategy.


Assuntos
Dispositivos de Proteção Embólica , Procedimentos Endovasculares/instrumentação , Isquemia/terapia , Extremidade Inferior/irrigação sanguínea , Tromboembolia/prevenção & controle , Doença Aguda , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Isquemia/diagnóstico , Pessoa de Meia-Idade , Tromboembolia/etiologia , Resultado do Tratamento
10.
J Interv Cardiol ; 23(4): 411-9, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20806458

RESUMO

Inherent risks of stenting include restenosis and thrombosis. Recently, stent fractures have been recognized as a complication that may result in thrombosis, perforation, restenosis, and migration of the stent resulting in morbidity and mortality. Stent fractures were originally seen in the superficial femoral arteries but have since then been reported in almost all vascular sites including the coronary, renal, carotid, iliac, and femoropopliteal arteries. Fractures are the result of the complex interplay between stent manufacturing, the stented segment, pulsatile and nonpulsatile biomechanical forces, and plaque morphology at a particular vascular site. The presentation of a patient with a fracture is highly variable, ranging from asymptomatic in nature, detected on routine screening without any sequelae, to sudden cardiac death related to a thrombosed coronary artery. Despite being recognized as an important complication, consensus on routine surveillance and diagnostic methods to detect fractures continues to be lacking. Fortunately, most cases are relatively benign and can be managed conservatively if detected. In the setting of recurrent symptoms, further intervention is usually sought. In review of the literature most cases are managed with placement of a stent over the fractured area, the stent-in-stent technique, but several other alternatives may be available. As the knowledge of the variables that make stents prone to fracture are identified, better technologies and techniques can be employed to minimize the risk of this complication. This article reviews the available literature on stent fractures and complications using data found on PubMed, MEDLINE, the Manufacturer and User Facility Device Experience (MAUDE) database, and the Cochrane databases.


Assuntos
Artérias/cirurgia , Falha de Prótese , Stents/efeitos adversos , Humanos , Desenho de Prótese
11.
Catheter Cardiovasc Interv ; 76(1): 16-23, 2010 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-20209644

RESUMO

OBJECTIVE: The objective of this study was to identify the predictors of distal embolization (DE) during protected renal artery angioplasty and stenting. BACKGROUND: DE may contribute to worsening renal function after renal artery stenting. The factors associated with DE, rates of platelet-rich emboli, and treatments that may prevent DE during renal stenting have not been evaluated. METHODS: The current study evaluated patients randomized to receive an embolic protection device (EPD) in the RESIST trial. Forty-two patients were identified for inclusion in this study. These patients were further randomized to abciximab (N = 22) or placebo (N = 20). Modification in Diet in Renal Disease glomerular filtration rate (GFR) was used as the primary measure of renal function. Creatinine was measured by a modified Jaffe reaction using the IDMS-traceable assay. The primary endpoint was capture of platelet rich emboli in the angioguard basket. RESULTS: DE occurred in 15/42 (35%) of the patients and platelet rich DE in 10 (24%) of the patients who received an EPD. Of the angiographic characteristics only lesion length was significantly higher in patients with DE (16 +/- 7 mm vs. 10 +/- 5 mm, P = 0.04). Preprocedural abciximab reduced DE from 42 to 8% (P = 0.02). The rate of platelet rich emboli was 50% with neither abciximab nor a thienopyridine, 36% with thienopyridine only, 15% abciximab only, and 0% in patients who received both a thienopyridine and abciximab. Only Abciximab use was associated with improved renal function at 1-month, thienopyridine was not. Angiographic characteristics including percent stenosis, minimal luminal diameter (MLD), reference diameter, change in MLD, contrast volume, and procedure time were not predictors of DE during renal stenting. CONCLUSION: Capture of DE and specifically platelet DE are common during protected renal stenting using a filter-type EPD. Abciximab use, and potentially combined thienopyridine and abciximab use, decreased the rate of platelet rich DE; however, only abciximab improved renal function at 1-month.


Assuntos
Angioplastia/instrumentação , Anticorpos Monoclonais/uso terapêutico , Embolia/prevenção & controle , Filtração/instrumentação , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Piridinas/uso terapêutico , Obstrução da Artéria Renal/terapia , Stents , Abciximab , Idoso , Idoso de 80 Anos ou mais , Angioplastia/efeitos adversos , Biomarcadores/sangue , Distribuição de Qui-Quadrado , Creatinina/sangue , Quimioterapia Combinada , Embolia/etiologia , Feminino , Taxa de Filtração Glomerular/efeitos dos fármacos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Obstrução da Artéria Renal/tratamento farmacológico , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
13.
Catheter Cardiovasc Interv ; 74(6): 966-9, 2009 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-19642198

RESUMO

Inferior vena cava (IVC) filters are being inserted with increasing frequency for the prevention of pulmonary embolus. Previous case reports have documented the passage of up to three electrode catheters or an individual long sheath through an IVC filter. The current report expands on prior series with regard to the number of devices used. We describe our experience in 10 patients in whom up to five electrode catheters and/or sheaths were placed through an IVC filter using a transfemoral approach under fluoroscopic guidance without routine venography. Devices were successfully introduced and withdrawn in each case without filter dislodgment. Our series illustrates the feasibility and safety of passing multiple electrode catheters and long sheaths through an IVC filter. Evidence is accumulating to suggest that an IVC filter should not be considered an absolute contraindication to performing diagnostic or therapeutic procedures.


Assuntos
Ablação por Cateter/instrumentação , Veia Femoral , Embolia Pulmonar/prevenção & controle , Filtros de Veia Cava , Veia Cava Inferior , Adulto , Idoso , Eletrodos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Veia Femoral/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Resultado do Tratamento , Filtros de Veia Cava/efeitos adversos
14.
Catheter Cardiovasc Interv ; 73(6): 725-30, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-19198007

RESUMO

OBJECTIVE: The aim of this study was to evaluate whether complete embolic protection is superior to partial embolic protection for preservation of kidney function during renal artery angioplasty and stenting. BACKGROUND: Renal artery angioplasty and stenting (RAAS) is a common treatment for atherosclerotic renal artery stenosis. However, RAAS may be complicated by peri-procedural loss of kidney function. METHODS: In total, 44 patients were randomized to embolic protection devices (EPD) use; 25 complete and 19 partial embolic protection. These patients were further randomized to receive abciximab (n = 23) or placebo (n = 21). [corrected] MDRD glomerular filtration rate (GFR), was used as the primary measure of renal function. Creatinine was measured by a modified Jaffe reaction using the IDMS-traceable assay. The primary endpoint was the percent change in estimated glomerular filtration rate (eGFR) 1 month following stent placement. RESULTS: There was no difference in percent change eGFR at 1 month between complete or partial protection (-4 +/- 25 vs. +3 +/- 30, P = 0.45). Abciximab was associated with a net improvement in eGFR when compared with placebo (+0.5 +/- 27 vs. -11 +/- 20, P = 0.04). On subgroup analysis, the use of abciximab was associated with significantly improved eGFR in the partial distal embolic protection group (+14 +/- 33 vs. -17 +/- 13 %, P = 0.018) but not in the complete distal embolic protection group (+2.5 +/- 26 vs. -11 +/- 24, P = 0.42), however, there was no interaction between completeness of protection and abciximab on eGFR (P = ns). Capture of embolic material was more likely with complete protection when compared with those receiving partial protection (51% vs. 21%, P < 0.05). CONCLUSION: Complete protection was superior to partial protection for the capture of athermanous debris during renal artery stenting. However, this was not associated with improved renal function. Importantly, Abciximab conferred a benefit for renal function that was independent of the degree of embolic protection.


Assuntos
Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Embolia/prevenção & controle , Obstrução da Artéria Renal/terapia , Insuficiência Renal/prevenção & controle , Stents , Abciximab , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais/uso terapêutico , Creatinina/sangue , Método Duplo-Cego , Embolia/etiologia , Feminino , Taxa de Filtração Glomerular , Humanos , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Obstrução da Artéria Renal/sangue , Obstrução da Artéria Renal/fisiopatologia , Insuficiência Renal/sangue , Insuficiência Renal/etiologia , Insuficiência Renal/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
16.
Catheter Cardiovasc Interv ; 72(4): 563-8, 2008 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-18819153

RESUMO

Radiation therapy is a cause of cardiovascular morbidity and mortality. This is due to the significant degree of atherosclerosis seen in the vessels in the vicinity of the area being irradiated. Radiation-induced peripheral arterial disease is increasingly being recognized as large populations of cancer patients survive longer, yet it is a problem that is often under reported. Although it has most commonly been associated with carotid artery disease, all vascular beds are prone to this form of injury. The injury is accelerated by usual risk factors for atherosclerosis. Developing a healthy lifestyle, dietary prudence and the aggressive treatment of hypertension, diabetes mellitus, and dyslipidemia should all be encouraged in this patient population. When revascularization strategies are warranted, the percutaneous approach may be superior to open surgery as technical difficulties may arise in the fibrotic, scarred tissue. Stenting with distal embolic protection devices should be considered as the treatment of choice for patients with radiation-induced carotid artery disease. Several reports also suggest good results with balloon angioplasty with or without stenting in the case of radiation-induced renal, iliac, and femoral artery disease. Lifelong antiplatelet therapy may be appropriate.


Assuntos
Neoplasias/radioterapia , Doenças Vasculares Periféricas/etiologia , Lesões por Radiação/etiologia , Aterosclerose/etiologia , Doenças das Artérias Carótidas/etiologia , Artéria Femoral/efeitos da radiação , Humanos , Artéria Ilíaca/efeitos da radiação , Doenças Vasculares Periféricas/fisiopatologia , Doenças Vasculares Periféricas/prevenção & controle , Doenças Vasculares Periféricas/terapia , Lesões por Radiação/fisiopatologia , Lesões por Radiação/prevenção & controle , Lesões por Radiação/terapia , Radioterapia/efeitos adversos , Artéria Renal/efeitos da radiação , Medição de Risco , Fatores de Risco , Artéria Subclávia/efeitos da radiação
17.
Circulation ; 117(21): 2752-60, 2008 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-18490527

RESUMO

BACKGROUND: Preservation of renal function is an important objective of renal artery stent procedures. Although atheroembolization can cause renal dysfunction during renal stent procedures, whether adjunctive use of embolic protection devices or glycoprotein IIb/IIIa inhibitors improves renal function is unknown. METHODS AND RESULTS: One hundred patients undergoing renal artery stenting at 7 centers were randomly assigned to an open-label embolic protection device, Angioguard, or double-blind use of a platelet glycoprotein IIb/IIIa inhibitor, abciximab, in a 2x2 factorial design. The main effects of treatments and their interaction were assessed on percentage change in Modification in Diet in Renal Disease-derived glomerular filtration rate from baseline to 1 month using centrally analyzed creatinine. Filter devices were analyzed for the presence of platelet-rich thrombus. With stenting alone, stenting and embolic protection, and stenting with abciximab alone, glomerular filtration rate declined (P<0.05), but with combination therapy, it did not decline and was superior to the other allocations in the 2x2 design (P<0.01). The main effects of treatment demonstrated no overall improvement in glomerular filtration rate; although abciximab was superior to placebo (0+/-27% versus -10+/-20%; P<0.05), embolic protection was not (-1+/-28% versus -10+/-20%; P=0.08). An interaction was observed between abciximab and embolic protection (P<0.05), favoring combination treatment. Abciximab reduced the occurrence of platelet-rich emboli in the filters from 42% to 7% (P<0.01). CONCLUSIONS: Renal artery stenting alone, stenting with embolic protection, and stenting with abciximab were associated with a decline in glomerular filtration rate. An unanticipated interaction between Angioguard and abciximab was seen, with combination therapy better than no treatment or either treatment alone.


Assuntos
Anticorpos Monoclonais/administração & dosagem , Embolia/prevenção & controle , Fragmentos Fab das Imunoglobulinas/administração & dosagem , Nefropatias/prevenção & controle , Inibidores da Agregação Plaquetária/administração & dosagem , Implantação de Prótese , Obstrução da Artéria Renal/cirurgia , Stents , Abciximab , Idoso , Idoso de 80 Anos ou mais , Angioplastia , Pressão Sanguínea , Terapia Combinada , Embolia/tratamento farmacológico , Feminino , Taxa de Filtração Glomerular , Hemorragia , Humanos , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Próteses e Implantes , Artéria Renal/cirurgia , Resultado do Tratamento
19.
Pacing Clin Electrophysiol ; 30(6): 810-2, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17547620

RESUMO

In the course of clinical practice, the electrophysiologist may encounter a wide variety of vascular abnormalities, which are important to recognize, as they may potentially impact on the health and welfare of the patient. We describe a case of bilateral inferior vena cava and review its etiology, diagnosis, and significance to the cardiologist and electrophysiologist.


Assuntos
Veia Cava Inferior/anormalidades , Veia Cava Inferior/fisiopatologia , Adulto , Eletrofisiologia , Feminino , Humanos
20.
Pacing Clin Electrophysiol ; 29(11): 1310-1, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17100690

RESUMO

In the course of clinical practice the electrophysiologist may encounter a variety of vascular abnormalities which are important to recognize, as they may impact upon the health and welfare of the patient. We describe a case of iliac vein compression (May-Thurner) syndrome and review its etiology, diagnosis, significance, and treatment.


Assuntos
Eletrocardiografia/métodos , Veia Ilíaca/anormalidades , Veia Ilíaca/diagnóstico por imagem , Doenças Vasculares Periféricas/diagnóstico , Trombose Venosa/diagnóstico , Adulto , Feminino , Humanos , Flebografia , Doenças Raras/diagnóstico , Síndrome
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...