Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Hand (N Y) ; 18(7): 1069-1079, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35272518

RESUMO

Ligament reconstruction tendon interposition (LRTI) and suture-button suspensionplasty (SBS) are both common treatment options for trapeziometacarpal osteoarthritis. The primary purpose of this systematic review was to compare the subjective improvement in patient-reported outcomes in regard to disability for patients undergoing LRTI and SBS for trapeziometacarpal osteoarthritis. A secondary purpose was to compare the subjective improvement, objective outcome scores, and complication rates following both procedures. We performed a systematic review using PubMed, Scopus, and Embase to compare the clinical outcomes of LRTI and SBS. Inclusion criteria were level I-IV evidence articles reporting postoperative Disabilities of the Arm, Shoulder, and Hand (DASH) or QuickDASH scores. Study methodological quality, risk of bias, and recommendation strength were assessed. This systematic review included 31 studies for final analysis with 1289 thumbs undergoing LRTI (25 studies) and 113 thumbs undergoing SBS (6 studies). Both procedures demonstrated similar improvement in DASH and/or QuickDASH scores, while key pinch and grip strength inconsistently improved following both procedures. Complication rate was similar between the 2 procedures; LRTI 12% and SBS 13%. Although both LRTI and SBS seem to provide improved short-term patient-reported functional improvement and objective strength, there was significant heterogeneity within the included studies, and those studies discussing SBS were of lower quality evidence than those of LRTI. Thus, to truly delineate whether a difference exists between these 2 techniques for the treatment of first carpometacarpal joint arthritis, larger prospectively designed studies of high-quality evidence are necessary.


Assuntos
Osteoartrite , Procedimentos de Cirurgia Plástica , Humanos , Osteoartrite/cirurgia , Tendões/cirurgia , Ligamentos/cirurgia , Suturas
2.
Hand (N Y) ; 17(6): 1114-1121, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33605176

RESUMO

BACKGROUND: To determine if the "unaffected" hand in children with hemiplegic cerebral palsy (CP) is truly unaffected. METHODS: We performed a retrospective review of manual dexterity as measured by the Functional Dexterity Test (FDT) in 66 children (39 boys, 27 girls, mean age: 11 years 4 months) with hemiplegic CP. Data were stratified by Manual Ability Classification System (MACS) level, birth weight, and gestational age at birth, and compared with previously published normative values. RESULTS: The FDT speed of the less affected hand is significantly lower than typically developing (TD) children (P < .001). The development of dexterity is significantly lower than TD children (0.009 vs. 0.036 pegs/s/year, P < .001), with a deficit that increases with age. MACS score, birth weight, and age at gestation are not predictors of dexterity. The dexterity of the less affected hand is poorly correlated with that of the more affected hand. CONCLUSIONS: Both dexterity and rate of fine motor skill acquisition in the less affected hand of children with hemiplegic CP is significantly less than that of TD children. The less affected hand should be evaluated and included in comprehensive treatment plans for these children.


Assuntos
Paralisia Cerebral , Criança , Masculino , Feminino , Recém-Nascido , Humanos , Paralisia Cerebral/complicações , Hemiplegia , Peso ao Nascer , Mãos , Força da Mão
3.
J Hand Microsurg ; 13(3): 150-156, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34511831

RESUMO

Introduction The purpose of this study was to review and compare clinical outcomes between percutaneous needle fasciotomy (PNF) and collagenase Clostridium histolyticum (CCH) injection for the treatment of Dupuytren's contracture. Materials and Methods A systematic review was performed including all level I-III evidence studies investigating the clinical outcomes of PNF and CCH injection in the treatment of Dupuytren's contracture. Results Five studies (278 CCH patients, 225 PNF patients; 285 CCH fingers, 246 PNF fingers, 405 males, and 98 females) were analyzed. Two randomized studies were level I evidence, one randomized study was level II, and two nonrandomized studies were level III. Two studies analyzed a total of 205 patients, each demonstrating statistically superior outcomes in one outcome measure (contracture improvement and Michigan Hand Questionnaire (MHQ) satisfaction subscore) with PNF, while the remaining three studies demonstrated no significant differences in outcomes between the two techniques. Three studies reported a statistically higher rate of minor complications (local pain, edema, ecchymosis, lymphadenopathy, pruritis) with CCH, while the remaining two studies demonstrated no significant difference in complication rates. Conclusion For the treatment of Dupuytren's contracture, there is some evidence that suggests superior clinical outcomes of PNF compared with CCH and a higher minor complication rate with CCH.

4.
Hand (N Y) ; 16(5): 624-631, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-31690136

RESUMO

Background: Trigger finger release (TFR) is a commonly performed procedure. However, there is great variation in the setting, care pathway, anesthetic, and cost. We compared the institutional cost for isolated TFR before and after redesigning our clinical care pathway. Methods: Total direct cost to the health system (excluding the surgeon and anesthesiology costs) and time spent by the patient at the surgery center were collected for 1 hand surgeon's procedures at an ambulatory surgery center over a 3-year period. We implemented a redesigned pathway that altered phases of care and anesthetic use by transitioning from intravenous (IV) sedation to wide awake local anesthesia with no tourniquet. Cost data were reported as percentage change in the median and compared both pre- to post-implementation and with 2 control surgeons using the traditional pathway within the same center. Power analysis was based on prior work on a carpal tunnel pathway. Significance was defined by a P-value < .05. Results: Ten TFRs (90% local with IV sedation) and 44 TFRs (89% local alone) were performed pre- and post-implementation, respectively. From pre- to post-implementation, the study surgeon's total direct cost decreased by 18%, while the control surgeons decreased by 2%. Median time spent at the surgery center decreased by 41 minutes post-implementation with significantly shorter setup time in the operating room (OR), total time in the OR, and time spent in recovery prior to discharge. Conclusions: Redesigning the care pathway for TFR led to a decrease in institutional cost and patient time spent at the surgery center.


Assuntos
Síndrome do Túnel Carpal , Dedo em Gatilho , Anestesia Local , Síndrome do Túnel Carpal/cirurgia , Humanos , Melhoria de Qualidade , Torniquetes , Dedo em Gatilho/cirurgia
5.
J Wrist Surg ; 9(1): 22-28, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32025350

RESUMO

Background Arthroscopic electrothermal treatment of low-grade Geissler's scapholunate interosseous ligament (SLIL) tears has shown clinical benefit at short-term follow-up. Questions/Purpose This study aims to evaluate the long-term functional outcomes in patients undergoing this treatment. Patients and Methods A retrospective review of all patients treated between 2005 and 2013 was performed. Patients were excluded with less than 5 years of follow-up, the presence of static SLIL injuries, prior wrist surgery, and concomitant denervation. Symptom resolution, return to activity, postoperative complications, range of motion, grip strength, and subsequent treatment were recorded. Each patient completed Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH), Modified Mayo Wrist (MMW), and Patient-Rated Wrist Evaluation (PRWE) questionnaires. Results Nine patients underwent treatment for Geissler's grade I, II, and III SLIL injuries with a mean 7 years (range: 5-11 years) of follow-up. Mean grip strength was 99% of the nonsurgical extremity. Wrist motion was near symmetric with a mean of 76 (±14), 74 (±8), 21 (±13), and 40 degrees (±13) for wrist flexion, extension, radial deviation, and ulnar deviation. QuickDASH improved significantly by a mean 39 points (50 (preoperative)-11 [postoperative], p = 0.009). Postoperative MMW and PRWE scores were 83 and 14, respectively. Visual analog scale (VAS) score was 1.4. A total of 90% was returned to their preinjury level of function or higher. Conclusions Arthroscopic electrothermal treatment of low-grade Geissler's SLIL tears demonstrates excellent objective and subjective outcomes at a minimum 5-year follow-up, providing evidence that this is an effective, safe, and, most importantly, durable-therapeutic modality. Level of Evidence This is a Level IV, case series study.

6.
J Wrist Surg ; 8(5): 403-407, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31579550

RESUMO

Background A pre-tied suture device has been utilized for all-arthroscopic peripheral triangular fibrocartilage complex (TFCC) repairs with promising early clinical results. Purpose The purpose of this study was to evaluate long-term functional outcomes of these repairs. Patients and Methods A retrospective review of patients undergoing arthroscopic TFCC repair was performed. Inclusion criteria were the Palmer type 1B TFCC tears diagnosed on arthroscopy and repaired using the all-arthroscopic pre-tied suture device. Patients with any evidence of concomitant wrist injury at the time of surgery, history of prior wrist surgery, or nonrepairable and nonperipheral TFCC tears were excluded. Postoperative complications, range of motion, grip strength, and outcome assessments were recorded for each patient. Results Eleven patients (mean age, 36 years; range, 20-64 years) satisfied our inclusion criteria and comprised the study cohort. The mean follow-up period was 7.0 years (range, 4.3-10.9 years). Mean range of motion of the wrist revealed flexion of 76 ± 11 degrees and extension of 73 ± 12 degrees. Mean grip strength was 98 ± 15% of the nonsurgical extremity. QuickDASH, modified Mayo, and patient-rated wrist evaluation (PRWE) average scores were 9 ± 8, 80 ± 6, and 12 ± 12, respectively. No surgical complications were observed and no patient required any further surgical intervention. Conclusions Our cohort of patients following all-arthroscopic pre-tied suture device repair of isolated Palmer type 1B TFCC tears demonstrated excellent clinical function at a mean follow-up of 7 years. These findings indicate that the pre-tied suture device is a reliable, safe, effective, and most importantly, durable treatment option for repair of peripheral TFCC tears. Level of Evidence This is a Level IV, therapeutic study.

7.
Clin Orthop Relat Res ; 477(10): 2332-2341, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31389880

RESUMO

BACKGROUND: Although current guidelines do not recommend the routine use of surgical antibiotic prophylaxis to reduce the risk of surgical site infection following clean, soft tissue hand surgery, antibiotics are nevertheless often used in patients with an existing joint prosthesis to prevent periprosthetic joint infection (PJI), despite little data to support this practice. QUESTIONS/PURPOSES: (1) Is clean, soft tissue hand surgery after THA or TKA associated with PJI risk? (2) Does surgical antibiotic prophylaxis before hand surgery decrease PJI risk in patients with recent THA or TKA? METHODS: We assessed all patients who underwent THA or TKA between January 2007 and December 2015 by retrospective analysis of the IBM® MarketScan® Databases, which provide a longitudinal view of all healthcare services used by a nationwide sample of millions of patients under commercial and supplemental Medicare insurance coverage-particularly advantageous given the relatively low frequency of hand surgery after THA/TKA and of subsequent PJI. The initial search yielded 940,861 patients, from which 509,896 were excluded for not meeting continuous enrollment criteria, having a diagnosis of PJI before the observation period, or having another arthroplasty procedure before or during the observation period; the final study cohort consisted of 430,965 patients of which 147,398 underwent THA and 283,567 underwent TKA. In the treated cohort, 8489 patients underwent carpal tunnel release, trigger finger release, ganglion or retinacular cyst excision, de Quervain's release, or soft-tissue mass excision within 2 years of THA or TKA. The control cohort was comprised of 422,476 patients who underwent THA or TKA but did not have subsequent hand surgery. The primary outcome was diagnosis or surgical management of a PJI within 90 days of the index hand surgery for the treated cohort, or within a randomly assigned 90-day observation period for each patient in the control group. Propensity score matching was used to match treated and control cohorts by patient and treatment characteristics and previously-reported risk factors for PJI. Logistic regression before and after propensity score matching was used to assess the association of hand surgery with PJI risk and the association of surgical antibiotic prophylaxis before hand surgery with PJI risk in the treated cohort. Other possible PJI risk factors were also explored in multivariable logistic regression. Statistical significance was assessed at α = 0.01. RESULTS: Hand surgery was not associated with PJI risk after propensity score matching of treated and control cohorts (OR, 1.39; 99% CI, 0.60-3.22; p = 0.310). Among patients who underwent hand surgery after arthroplasty, surgical antibiotic prophylaxis before hand surgery was not associated with decreased PJI risk (OR 0.42; 99% CI, 0.03-6.08; p = 0.400). CONCLUSIONS: Clean, soft-tissue hand surgery was not found to be associated with PJI risk in patients who had undergone primary THA or TKA within 2 years before their hand procedure. While the effect of PJIs can be devastating, we do not find increased risk of infection with hand surgery nor data supporting routine use of surgical antibiotic prophylaxis in this setting. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Antibioticoprofilaxia , Procedimentos Cirúrgicos Eletivos , Mãos/cirurgia , Prótese de Quadril/efeitos adversos , Prótese do Joelho/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/prevenção & controle , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/epidemiologia , Estudos Retrospectivos , Medição de Risco
8.
J Hand Surg Am ; 44(11): 990.e1-990.e7, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30797658

RESUMO

PURPOSE: Conventional angiography is often used in the preoperative work-up of hand surgery patients with systemic sclerosis. The goal of this study was to propose a classification system based on the pattern of arterial involvement in a series of upper extremity angiograms. The authors hypothesized that this classification system would demonstrate high inter- and intrarater reliability. METHODS: A retrospective review of 110 upper extremity angiograms in patients with systemic sclerosis (obtained between 1996 and 2017) was performed. Images were classified into 4 types based on the patency of the radial and ulnar arteries at the wrist, and into 3 subtypes based on the patency of the superficial and deep palmar arches. Classification reliability was compared with Fleiss' Kappa (for inter-rater) and Cohen's (for intrarater) coefficient between 4 fellowship-trained hand surgeons and a hand fellow. RESULTS: The inter-rater reliability between all 5 observers using types alone was 0.83 (0.80-0.85), whereas the inter-rater reliability using subtypes was 0.64 (confidence interval [CI] 95%, 0.62-0.65). The intrarater reliability using types alone ranged from 0.80 to 0.95, whereas intrarater reliabilities using subtypes were 0.81 (CI 95%, 0.72-0.90), 0.78 (CI 95%, 0.69-0.87), 0.87 (CI 95%, 0.80-0.95), 0.64 (CI 95%, 0.53-0.75), and 0.92 (CI 95%, 0.86-0.98) for the 4 attendings and a hand fellow, respectively. Fifty-seven percent of angiograms were interpreted as having loss of ulnar artery patency at the wrist (type 2) with 77% having additional loss of superficial palmar arch patency (type 2A). CONCLUSIONS: This large series of angiograms in patients with systemic sclerosis demonstrates a classification system for conventional angiography that shows high inter-rater and intrarater reliability using type alone. When subtypes were used, the inter-rater and intrarater reliabilities decreased to moderate and moderate-to-high, respectively. CLINICAL RELEVANCE: This study represents the first step in establishing a classification system that, by grouping patients with similar angiogram findings, may allow for targeted research into risk stratification, monitoring, and treatment in systemic sclerosis.


Assuntos
Angiografia/classificação , Angiografia/métodos , Escleroderma Sistêmico/diagnóstico por imagem , Escleroderma Sistêmico/cirurgia , Extremidade Superior/irrigação sanguínea , Adulto , Fatores Etários , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Artéria Radial/diagnóstico por imagem , Estudos Retrospectivos , Medição de Risco , Escleroderma Sistêmico/fisiopatologia , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Fatores Sexuais , Artéria Ulnar/diagnóstico por imagem , Extremidade Superior/diagnóstico por imagem , Extremidade Superior/fisiopatologia
9.
Orthopedics ; 41(4): e445-e456, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29658974

RESUMO

The purpose of this study was to determine the proportion of questions used by online physician rating scales to directly rate physicians themselves. A systematic review was performed of online, patient-reported physician rating scales. Fourteen websites were identified containing patient-reported physician rating scales, with the most common questions pertaining to office staff courtesy, wait time, overall rating (entered, not calculated), trust/confidence in physician, and time spent with patient. Overall, 28% directly rated the physician, 48% rated both the physician and the office, and 24% rated the office alone. There is great variation in the questions used, and most fail to directly rate physicians themselves. [Orthopedics. 2018; 41(4):e445-e456.].


Assuntos
Internet , Satisfação do Paciente , Médicos/normas , Pessoal Administrativo/normas , Humanos , Relações Médico-Paciente , Inquéritos e Questionários , Fatores de Tempo , Confiança
10.
Am J Sports Med ; 46(7): 1720-1726, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29601208

RESUMO

BACKGROUND: The anterior bundle of the medial ulnar collateral ligament (UCL) is the primary restraint to valgus stress at the elbow and is often injured among overhead throwing athletes. Despite prevention strategies, injuries to the elbow UCL are on the rise. PURPOSE: To determine (1) the return-to-sport (RTS) rate of Major League Baseball (MLB) position players after elbow medial UCL reconstruction, (2) postoperative career length and games per season, (3) pre- and postoperative performance, (4) postoperative performance versus matched control players, and (5) whether position players changed positions after UCL reconstruction. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: MLB players who underwent elbow UCL reconstruction were identified (cases). Demographic and performance data were collected for each player. Matched controls were identified. RTS in MLB was defined as playing in at least 1 MLB game after UCL reconstruction. Comparisons between case and control groups and pre- and postoperative time points were made via paired samples Student t tests. RESULTS: Thirty-three players (34 surgical procedures) were identified with a mean ± SD age of 30.2 ± 4.2 years and a mean experience in the MLB of 6.3 ± 3.9 years at the time of surgery. Twenty-eight players (84.8%) were able to RTS in MLB at a mean 336.9 ± 121.8 days. However, players ≥30 years old demonstrated a significantly lower RTS rate (53.3%) than players <30 years old (89.4%; P < .05). Catchers had a significantly shorter postoperative career length (2.8 ± 1.8 years) versus matched controls (6.1 ± 1.9 years; P < .05). Outfielders had a significantly lower wins above replacement postoperatively (0.8 ± 0.7) versus preoperatively (1.5 ± 1.1; P < .05). There were no performance differences between cases and matched controls. Twelve players (48%) returned to a different position postoperatively. CONCLUSION: The RTS rate for MLB position players after elbow UCL reconstruction is similar to that of pitchers. Catchers had a significantly shorter career length than that of matched controls. Outfielders performed worse postoperatively versus preoperatively. There is a high rate of position change after Tommy John surgery for infielders and outfielders.


Assuntos
Traumatismos em Atletas/cirurgia , Beisebol/lesões , Volta ao Esporte , Reconstrução do Ligamento Colateral Ulnar , Adulto , Atletas , Estudos de Casos e Controles , Estudos de Coortes , Ligamento Colateral Ulnar/lesões , Cotovelo/cirurgia , Humanos , Ligamentos Articulares/cirurgia , Masculino , Período Pós-Operatório , Ulna/cirurgia , Lesões no Cotovelo
11.
J Orthop Sci ; 23(2): 310-315, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29274738

RESUMO

BACKGROUND: Accurate measurements of shoulder and elbow motion are required for the management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. METHODS: Using infrared motion capture analysis as the reference standard, shoulder flexion/abduction/internal rotation/external rotation and elbow flexion/extension were measured using visual estimation, goniometry, and digital photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard (motion capture analysis), while precision was defined by the proportion of measurements within the authors' definition of clinical significance (10° for all motions except for elbow extension where 5° was used). Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. RESULTS: Although statistically significant differences were found in measurement accuracy between the three techniques, none of these differences met the authors' definition of clinical significance. Precision of the measurements was significantly higher for both digital photography (shoulder abduction [93% vs. 74%, p < 0.001], shoulder internal rotation [97% vs. 83%, p = 0.001], and elbow flexion [93% vs. 65%, p < 0.001]) and goniometry (shoulder abduction [92% vs. 74%, p < 0.001] and shoulder internal rotation [94% vs. 83%, p = 0.008]) than visual estimation. Digital photography was more precise than goniometry for measurements of elbow flexion only [93% vs. 76%, p < 0.001]. CONCLUSIONS: There was no clinically significant difference in measurement accuracy between the three techniques for shoulder and elbow motion. Digital photography showed higher measurement precision compared to visual estimation for shoulder abduction, shoulder internal rotation, and elbow flexion. However, digital photography was only more precise than goniometry for measurements of elbow flexion. Overall digital photography shows equivalent accuracy to visual estimation and goniometry, but with higher precision than visual estimation.


Assuntos
Artrometria Articular/métodos , Articulação do Cotovelo/fisiologia , Fotografação/métodos , Amplitude de Movimento Articular/fisiologia , Articulação do Ombro/fisiologia , Cadáver , Humanos , Masculino , Sensibilidade e Especificidade
12.
J Surg Educ ; 75(3): 739-748, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29037822

RESUMO

OBJECTIVES: Comparison of range of motion measurements by 3 types of investigators with different levels and types of training using three different measurement techniques. The study hypothesis was that the accuracy and precision of range of motion measurements would vary based on (1) the level and type of experience of the investigator and (2) the measurement technique used. DESIGN/SETTING: Descriptive laboratory study. PARTICIPANTS: Ten fresh frozen cadavers (20 upper and 20 lower extremities). INTERVENTIONS: Shoulder, elbow, hip, and knee motion were measured using 3 different measurement techniques (digital photography, goniometry, and visual estimation) by 3 groups of investigators (attending orthopedic surgeons, physical therapists, and residents). Accuracy was defined by the difference from the reference standard (motion capture analysis), whereas precision was defined by the proportion of measurements within either 5° or 10° of the reference standard. Analysis of variance, t-tests, and chi-squared tests were used. RESULTS: Statistically significant (p < 0.05) differences in accuracy were found for hip flexion, abduction, internal rotation, external rotation, and knee flexion. However, none of these differences met the authors' defined clinical significance (maximum difference 3°). Precision was significantly (p < 0.05) different for elbow extension, hip flexion, abduction, internal rotation, external rotation, and knee flexion. CONCLUSION: This study found that clinically accurate measurements of shoulder, elbow, hip, and knee motion are obtained regardless of technique used or the investigators' level and type of experience. Precision was equivalent for all shoulder motions, elbow flexion, and knee extension, but varied by as much as 7% to 28% between groups for all other motions.


Assuntos
Competência Clínica , Educação de Pós-Graduação em Medicina/métodos , Amplitude de Movimento Articular/fisiologia , Artrometria Articular , Cadáver , Humanos , Internato e Residência , Extremidade Inferior/fisiologia , Ortopedia/educação , Fisioterapeutas/educação , Sensibilidade e Especificidade , Extremidade Superior/fisiologia
13.
Hand (N Y) ; 13(3): 264-274, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28720043

RESUMO

Background: Approximately 10% of patients with lateral epicondylitis go on to have surgical treatment; however, multiple surgical treatment options exist. The purpose of this study was to review the literature for the clinical outcomes of open, arthroscopic, and percutaneous treatment of lateral epicondylitis. The authors hypothesized that the clinical outcome of all 3 analyzed surgical treatments would be equivalent. Methods: A systematic review was performed using PubMed, Cochrane Central Register of Controlled Trials, and Google Scholar in July 2016 to compare the functional outcome, pain, grip strength, patient satisfaction, and return to work at 1-year follow-up for open, arthroscopic, and percutaneous treatment of lateral epicondylitis. Results: Six studies (2 Level I and 4 Level II) including 179 elbows (83 treated open, 14 arthroscopic, 82 percutaneous) were analyzed. Three outcome measures (Disabilities of the Arm, Shoulder, and Hand [DASH] score, visual analog scale [VAS], and patient satisfaction) were reported for more than one category of surgical technique. Of these, the authors noted no clinically significant differences between the techniques. Conclusions: This is the first systematic review looking at high-level evidence to compare open, percutaneous, and arthroscopic techniques for treating lateral epicondylitis. There are no clinically significant differences between the 3 surgical techniques (open, arthroscopic, and percutaneous) in terms of functional outcome (DASH), pain intensity (VAS), and patient satisfaction at 1-year follow-up.

14.
Arthroscopy ; 33(12): 2248-2254, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29066268

RESUMO

PURPOSE: To use simulated arthroscopic knot tying to assess (1) whether epithelial cells from the surgeon's hands were transmitted to the suture and (2) whether the number of knots tied or the presence of glove tears would correlate with the number of cells transmitted. METHODS: Knots were tied in a simulated arthroscopic environment using a nonabsorbable No. 2 suture over a metal hook. The surgeon was double gloved for each knot tied. For each "anchor," a surgeon's knot was tied, followed by 3 reversed half-hitches on alternating posts. Multiple skin lacerations were sustained by the surgeon during each knot-tying session. Gloves were collected after tying 2, 4, or 6 anchors. Gloves were tested for perforation by (1) electroconductivity and (2) saline solution load testing. Cytopathologic ThinPrep analysis was applied and allowed for the number of epithelial cells found on each suture (within 10 high-powered fields) to be counted. Statistical analysis included analysis of variance and logistic regression. RESULTS: There was no significant difference in the number of epithelial cells identified in any of the groups compared with the negative control groups (P > .05) or with each other (P > .05). Glove tears were present in 3.3% of gloves (50% in inner and 50% in outer gloves) and 1.7% of gloves (50% in inner and 50% in outer gloves) by electroconductivity and saline solution load testing, respectively. There was no significant association between glove tears and the number of epithelial cells found on the suture (P > .05). CONCLUSIONS: Epithelial cells were transmitted to the suture during simulated arthroscopic knot tying. However, despite multiple skin lacerations produced during knot-tying sessions, the number of cells transmitted was not significantly different when compared with the negative controls. The number of cells transmitted did not correlate with the number of knots tied and/or the presence of glove tears. CLINICAL RELEVANCE: Skin lacerations on the surgeon's fingers are often noted after arthroscopic knot tying. However, despite these skin lacerations, no skin tissue is transferred across the surgical gloves to the suture itself.


Assuntos
Artroscopia , Células Epiteliais/citologia , Luvas Cirúrgicas , Pele/lesões , Suturas , Contagem de Células , Falha de Equipamento , Humanos , Lacerações , Cirurgiões
15.
J Exp Orthop ; 4(1): 29, 2017 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-28884315

RESUMO

BACKGROUND: Accurate measurements of knee and hip motion are required for management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion at the hip and knee. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. METHODS: Using infrared motion capture analysis as the reference standard, hip flexion/abduction/internal rotation/external rotation and knee flexion/extension were measured using visual estimation, goniometry, and photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard, while precision was defined by the proportion of measurements within either 5° or 10°. Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. RESULTS: Although two statistically significant differences were found in measurement accuracy between the three techniques, neither of these differences met clinical significance (difference of 1.4° for hip abduction and 1.7° for the knee extension). Precision of measurements was significantly higher for digital photography than: (i) visual estimation for hip abduction and knee extension, and (ii) goniometry for knee extension only. CONCLUSIONS: There was no clinically significant difference in measurement accuracy between the three techniques for hip and knee motion. Digital photography only showed higher precision for two joint motions (hip abduction and knee extension). Overall digital photography shows equivalent accuracy and near-equivalent precision to visual estimation and goniometry.

16.
Orthop J Sports Med ; 4(2): 2325967115627608, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26962539

RESUMO

BACKGROUND: Scapular dyskinesis, or abnormal dynamic scapular control, is a condition that is commonly associated with shoulder pathology but is also present in asymptomatic individuals. Literature varies on whether it represents a cause or symptom of shoulder pathology, but it is believed to be a risk factor for further injury. Clinical identification focuses on visual observation and examination maneuvers. Treatment of altered scapular motion has been shown to improve shoulder symptoms. It is thought to be more common in overhead athletes due to their reliance on unilateral upper extremity function but the incidence within nonoverhead athletes is unknown. HYPOTHESIS: Overhead athletes will have a greater prevalence of scapular dyskinesis when compared with nonoverhead athletes. STUDY DESIGN: Systematic review; Level of evidence, 3. METHODS: After PROSPERO registration, a systematic review was performed using PRISMA guidelines through the PubMed database looking for studies published before October 2014. All studies containing the search terms scapular, scapulothoracic, dyskinesis, dyskinesia, shoulder athlete, or overhead athlete were included. Studies that did not include prevalence data for scapular dyskinesis were excluded. Study methodological quality was evaluated using the modified Coleman methodology score. Descriptive statistics and 2-proportion 2-tailed z-tests were used to compare the reported prevalence of scapular dyskinesis between overhead and nonoverhead athletes. RESULTS: Twelve studies were analyzed including 1401 athletes (1257 overhead and 144 nonoverhead; mean age, 24.4 ± 7.1 years; 78% men). All the studies were evidence level 2 (33%) or level 3 (67%). The reported prevalence of scapular dyskinesis was significantly (P < .0001) higher in overhead athletes (61%) compared with nonoverhead athletes (33%). CONCLUSION: Scapular dyskinesis was found to have a greater reported prevalence (61%) in overhead athletes compared with nonoverhead athletes (33%). CLINICAL RELEVANCE: Prevalence data for scapular dyskinesis are scarce within the literature. Information on the reported prevalence, laterality, and association with the dominant extremity will allow for better allocation of diagnostic and therapeutic interventions. Recognition and treatment will help athletes to optimize functional performance and decrease the risk of further shoulder injury.

17.
J Hand Surg Am ; 41(5): e103-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26972557

RESUMO

Children with hand reductions, whether congenital or traumatic, have unique prosthetic needs. They present a challenge because of their continually changing size due to physical growth as well as changing needs due to psychosocial development. Conventional prosthetics are becoming more technologically advanced and increasingly complex. Although these are welcome advances for adults, the concomitant increases in weight, moving parts, and cost are not beneficial for children. Pediatric prosthetic needs may be better met with simpler solutions. Three-dimensional printing can be used to fabricate rugged, light-weight, easily replaceable, and very low cost assistive hands for children.


Assuntos
Membros Artificiais , Mãos , Impressão Tridimensional , Desenho de Prótese , Criança , Humanos
18.
J Bone Joint Surg Am ; 96(6): 481-7, 2014 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-24647504

RESUMO

BACKGROUND: The Rejuvenate modular-neck stem implant (Stryker Orthopaedics, Mahwah, New Jersey) was recently recalled due to corrosion at the femoral neck-stem junction. The purpose of this study was to investigate the rate of corrosion-related failure and survivorship of this implant and analyze the correlation of implant and patient factors with serum metal ion levels and revisions. METHODS: From June 2009 to July 2012, 123 Rejuvenate total hip arthroplasty stems (ninety-seven modular and twenty-six non-modular) were implanted in 104 patients by a single surgeon. Serum cobalt (Co) and chromium (Cr) levels (micrograms per liter [µg/L]) were measured postoperatively for all patients. Patients with persistent hip pain or elevated metal ion levels underwent magnetic resonance imaging for assessment of osteolysis or adverse local tissue reactions. Correlation of implant factors (stem size, head size, head length, and femoral head-neck offset) and patient factors (age, sex, and body mass index) with serum metal ion levels and revisions were analyzed with use of logistic regression models. RESULTS: The mean duration of follow-up (and standard deviation) was 2.7 ± 0.6 years. The mean Co and Cr levels were 5.4 ± 5.7 µg/L (range, 0.2 to 31 µg/L) and 2.1 ± 1.5 µg/L (range, 0.1 to 4.3 µg/L), respectively. The differences in Co and Cr levels between the two groups (modular and non-modular) were significant: 48% of the total hip arthroplasties in the modular group resulted in elevated metal ion levels (Co >4.0 µg/L and Cr >2.0 µg/L; p < 0.05). The metal ion levels in the non-modular group were normal. In the modular group, higher metal ion levels were significantly correlated with younger age and a higher femoral head-neck offset (p = 0.04). Pain and high Co serum levels were significant predictors of revision surgery (p = 0.006). The rate of revision at the time of this study was 28% in the modular group, with the majority of the revisions performed in the second year after surgery; the Kaplan-Meier survivorship was 40% at four years. CONCLUSIONS: The short-term high rate of corrosion-related revision with Rejuvenate modular-neck stems is striking.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Cromo/sangue , Cobalto/sangue , Corrosão , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...