Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
J Chem Phys ; 159(3)2023 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-37458342

RESUMO

Phosphorescent organic light emitting diodes (OLEDs) suffer from efficiency roll off, where device efficiency rapidly decays at higher luminance. One strategy to minimize this loss of efficiency at higher luminance is the use of non-uniform or graded guest:host blend ratios within the emissive layer. This work applies a multi-scale modeling framework to elucidate the mechanisms by which a non-uniform blend ratio can change the performance of an OLED. Mobility and exciton data are extracted from a kinetic Monte-Carlo model, which is then coupled to a drift diffusion model for fast sampling of the parameter space. The model is applied to OLEDs with uniform, linear, and stepwise graduations in the blend ratio in the emissive layer. The distribution of the guests in the film was found to affect the mobility of the charge carriers, and it was determined that having a graduated guest profile broadened the recombination zone, leading to a reduction in second order annihilation rates. That is, there was a reduction in triplet-triplet and triplet-polaron annihilation. Reducing triplet-triplet and triplet-polaron annihilation would lead to an improvement in device efficiency.

2.
Phys Chem Chem Phys ; 25(19): 13244-13259, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37144605

RESUMO

Luminescence-based sensing is capable of being used for the sensitive, rapid, and in some cases selective detection of chemicals. Furthermore, the method is amenable to incorporation into handheld low-power portable detectors that can be used in the field. Luminescence-based detectors are now commercially available for explosive detection with the technology built on a strong foundation of science. In contrast, there are fewer examples of luminescence-based detection of illicit drugs, despite the pervasive and global challenge of combating their manufacture, distribution and consumption and the need for handheld detection systems. This perspective describes the relatively nascent steps that have been reported in the use of luminescent materials for the detection of illicit drugs. Much of the published work has focused on detection of illicit drugs in solution with less work on vapour detection using thin luminescent sensing films. The latter are better suited for handheld sensing devices and detection in the field. Illicit drug detection has been achieved via different mechanisms, all of which change the luminescence of the sensing material. These include photoinduced hole transfer (PHT) leading to quenching of the luminescence, disruption of Förster energy transfer between different chromophores by a drug, and chemical reaction between the sensing material and a drug. The most promising of these is PHT, which can be used for rapid and reversible detection of illicit drugs in solution and film-based sensing of drugs in the vapour phase. However, there are still significant knowledge gaps, for example, how vapours of illicit drugs interact with the sensing films, and how to achieve selectivity for specific drugs.


Assuntos
Drogas Ilícitas , Luminescência , Gases , Filmes Cinematográficos
3.
Ann R Coll Surg Engl ; 103(5): e151-e155, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33930284

RESUMO

The diagnosis of visceral perforation during pregnancy is often delayed and the management complex. A 32-year-old primigravid woman in her second trimester presented with abdominal pain and a pre-existing ileoanal pouch. Initial imaging was negative but later imaging was suggestive of serious pathology. At laparotomy, a caesarean section was performed. Peritonitis was encountered secondary to two discrete perforations in the small bowel separate from her pouch. Histology found an ischaemic perforation secondary to a pressure effect from the gravid uterus. In pregnancy, ileoanal pouches may make the interconnected bowel vulnerable to the pressure effect of the gravid uterus and perforation. Pregnant women with such a surgical history who develop symptoms suggestive of bowel perforation should have rapid imaging and their clinical team should consider early definitive surgical intervention.


Assuntos
Bolsas Cólicas , Doenças Inflamatórias Intestinais/complicações , Perfuração Intestinal , Isquemia , Complicações na Gravidez , Dor Abdominal , Adulto , Cesárea , Feminino , Humanos , Perfuração Intestinal/diagnóstico , Perfuração Intestinal/cirurgia , Intestino Delgado/cirurgia , Isquemia/diagnóstico , Isquemia/cirurgia , Laparotomia , Peritonite/diagnóstico , Peritonite/cirurgia , Gravidez
4.
Nat Commun ; 12(1): 465, 2021 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-33469009

RESUMO

Electron and hole spins in organic light-emitting diodes constitute prototypical two-level systems for the exploration of the ultrastrong-drive regime of light-matter interactions. Floquet solutions to the time-dependent Hamiltonian of pairs of electron and hole spins reveal that, under non-perturbative resonant drive, when spin-Rabi frequencies become comparable to the Larmor frequencies, hybrid light-matter states emerge that enable dipole-forbidden multi-quantum transitions at integer and fractional g-factors. To probe these phenomena experimentally, we develop an electrically detected magnetic-resonance experiment supporting oscillating driving fields comparable in amplitude to the static field defining the Zeeman splitting; and an organic semiconductor characterized by minimal local hyperfine fields allowing the non-perturbative light-matter interactions to be resolved. The experimental confirmation of the predicted Floquet states under strong-drive conditions demonstrates the presence of hybrid light-matter spin excitations at room temperature. These dressed states are insensitive to power broadening, display Bloch-Siegert-like shifts, and are suggestive of long spin coherence times, implying potential applicability for quantum sensing.

5.
Clin Radiol ; 74(11): 894.e19-894.e25, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31296337

RESUMO

AIM: To assess prostate magnetic resonance imaging (MRI) image quality and compliance with technical standards between centres in the South West region of the UK. MATERIALS AND METHODS: Fifteen imaging sites in the region submitted seven consecutive anonymised MRI studies. These were assessed by two experienced radiologists in consensus. Overall, subjective image quality for T2-weighted imaging (T2W), diffusion weighted imaging (DWI), and dynamic contrast enhancement (DCE) was scored on a five-point Likert scale. Five additional quality parameters were also assessed visually, including image noise, motion, artefact, and distortion. The degree of compliance by each site with 21 published technical standards was also assessed. RESULTS: Ninety-four MRI examinations were reviewed from across all sites (mean 6.3 scans per site, range 5-7). Mean compliance with technical standards was 63% (range 38-86%). Forty-seven percent of sites did not perform DCE. One site used a 3 T scanner. The percentage of patients with overall quality scores of ≥3 (diagnostically acceptable) were 68% for T2W, 81% for DWI, and 60% for both T2W and DWI. Ninety-three percent of the 45 patients who underwent DCE had diagnostically acceptable studies. By scanner age, the percentage of patients with diagnostically acceptable T2W scores was 53% for scanners ≥7 years and 80% when <7 years (p=0.006). Comparing individual sites, the mean overall quality scores were 2.9 (range 2.2-4.2) for T2W, 3.2 (1.8-4.7) for DWI, and 3.4 (2.5-4.7) for DCE. CONCLUSION: There is wide variation in compliance with recognised technical standards and image quality across sites. If MRI is to replace biopsy in selected low-risk patients, improvements in image quality may be required.


Assuntos
Imageamento por Ressonância Magnética/normas , Neoplasias da Próstata/patologia , Desenho de Equipamento , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Prática Profissional/normas , Prática Profissional/estatística & dados numéricos , Qualidade da Assistência à Saúde , Padrões de Referência , Reino Unido
6.
Phys Chem Chem Phys ; 19(44): 29714-29730, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-28850131

RESUMO

The detection of explosives continues to be a pressing global challenge with many potential technologies being pursued by the scientific research community. Luminescence-based detection of explosive vapours with an organic semiconductor has attracted much interest because of its potential for detectors that have high sensitivity, compact form factor, simple operation and low-cost. Despite the abundance of literature on novel sensor materials systems there are relatively few mechanistic studies targeted towards vapour-based sensing. In this Perspective, we will review the progress that has been made in understanding the processes that control the real-time luminescence quenching of thin films by analyte vapours. These are the non-radiative quenching process by which the sensor exciton decays, the analyte-sensor intermolecular binding interaction, and the diffusion process for the analyte vapours in the film. We comment on the contributions of each of these processes towards the sensing response and, in particular, the relative roles of analyte diffusion and exciton diffusion. While the latter has been historically judged to be one of, if not the primary, causes for the high sensitivity of many conjugated polymers to nitrated vapours, recent evidence suggests that long exciton diffusion lengths are unnecessary. The implications of these results on the development of sensor materials for real-time detection are discussed.

7.
Nanoscale ; 9(1): 251-257, 2017 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-27906401

RESUMO

The large surface roughness, low work function and high cost of transparent electrodes using multilayer graphene films can limit their application in organic photovoltaic (OPV) cells. Here, we develop single layer graphene (SLG) films as transparent anodes for OPV cells that contain light-absorbing layers comprised of the evaporable molecular organic semiconductor materials, zinc phthalocyanine (ZnPc)/fullerene (C60), as well as a molybdenum oxide (MoOx) interfacial layer. In addition to an increase in the optical transmittance, the SLG anodes had a significant decrease in surface roughness compared to two and four layer graphene (TLG and FLG) anodes fabricated by multiple transfer and stacking of SLGs. Importantly, the introduction of a MoOx interfacial layer not only reduced the energy barrier between the graphene anode and the active layer, but also decreased the resistance of the SLG by nearly ten times. The OPV cells with the structure of polyethylene terephthalate/SLG/MoOx/CuI/ZnPc/C60/bathocuproine/Al were flexible, and had a power conversion efficiency of up to 0.84%, which was only 17.6% lower than the devices with an equivalent structure but prepared on commercial indium tin oxide anodes. Furthermore, the devices with the SLG anode were 50% and 86.7% higher in efficiency than the cells with the TLG and FLG anodes. These results show the potential of SLG electrodes for flexible and wearable OPV cells as well as other organic optoelectronic devices.

8.
Phys Chem Chem Phys ; 18(5): 3575-80, 2016 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-26750542

RESUMO

We study the influence of the film thickness on the time-resolved phosphorescence and the luminescence quantum yield of fac-tris(2-phenylpyridyl)iridium(iii) [Ir(ppy)3]-cored dendrimers deposited on dielectric substrates. A correlation is observed between the surface quenching velocity and the quenching rate by intermolecular interactions in the bulk film, which suggests that both processes are controlled by dipole-dipole interactions between Ir(ppy)3 complexes at the core of the dendrimers. It is also found that the surface quenching velocity decreases as the refractive index of the substrate is increased. This can be explained by partial screening of dipole-dipole interactions by the dielectric environment.

9.
Chem Commun (Camb) ; 51(98): 17406-9, 2015 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-26465590

RESUMO

The diffusion of p-nitrotoluene vapours into polymer or dendrimer sensing films follows Super Case II dynamics in which the quenching efficiency is strongly correlated to an accelerating analyte front propagating through the neat film rather than being reliant on exciton diffusion.


Assuntos
Dendrímeros/química , Substâncias Explosivas/análise , Tolueno/análogos & derivados , Adsorção , Difusão , Substâncias Explosivas/química , Fluorescência , Cinética , Tolueno/análise , Tolueno/química
10.
Science ; 345(6203): 1487-90, 2014 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-25237097

RESUMO

The effects of external magnetic fields on the electrical conductivity of organic semiconductors have been attributed to hyperfine coupling of the spins of the charge carriers and hydrogen nuclei. We studied this coupling directly by implementation of pulsed electrically detected nuclear magnetic resonance spectroscopy in organic light-emitting diodes (OLEDs). The data revealed a fingerprint of the isotope (protium or deuterium) involved in the coherent spin precession observed in spin-echo envelope modulation. Furthermore, resonant control of the electric current by nuclear spin orientation was achieved with radiofrequency pulses in a double-resonance scheme, implying current control on energy scales one-millionth the magnitude of the thermal energy.

11.
Bone Joint J ; 95-B(2): 181-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23365026

RESUMO

The Cementless Oxford Unicompartmental Knee Replacement (OUKR) was developed to address problems related to cementation, and has been demonstrated in a randomised study to have similar clinical outcomes with fewer radiolucencies than observed with the cemented device. However, before its widespread use it is necessary to clarify contraindications and assess the complications. This requires a larger study than any previously published. We present a prospective multicentre series of 1000 cementless OUKRs in 881 patients at a minimum follow-up of one year. All patients had radiological assessment aligned to the bone-implant interfaces and clinical scores. Analysis was performed at a mean of 38.2 months (19 to 88) following surgery. A total of 17 patients died (comprising 19 knees (1.9%)), none as a result of surgery; there were no tibial or femoral loosenings. A total of 19 knees (1.9%) had significant implant-related complications or required revision. Implant survival at six years was 97.2%, and there was a partial radiolucency at the bone-implant interface in 72 knees (8.9%), with no complete radiolucencies. There was no significant increase in complication rate compared with cemented fixation (p = 0.87), and no specific contraindications to cementless fixation were identified. Cementless OUKR appears to be safe and reproducible in patients with end-stage anteromedial osteoarthritis of the knee, with radiological evidence of improved fixation compared with previous reports using cemented fixation.


Assuntos
Artroplastia do Joelho/instrumentação , Cimentos Ósseos/efeitos adversos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Osteoartrite do Joelho/cirurgia , Osteonecrose/cirurgia , Complicações Pós-Operatórias/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Feminino , Seguimentos , Humanos , Incidência , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Radiografia , Resultado do Tratamento
12.
Opt Express ; 20 Suppl 2: A213-8, 2012 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-22418670

RESUMO

We show that it is possible to produce an efficient solution-processable phosphorescent poly(dendrimer) OLED with a 32 lm/W power efficiency at 100 cd/m2 without using a charge transporting host or any improvements in light extraction. This is achieved by using the dendrimer architecture to control inter-chromophore interactions. The effects of using 4,4',4″-tris(N-carbazolyl)triphenylamine (TCTA) as a charge transporting host and using a double dendron structure to further reduce inter-chromophore interactions are also reported.

13.
Br J Radiol ; 85(1016): 1102-6, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22457319

RESUMO

OBJECTIVES: The objective of this study was to compare the relative conspicuity of bone metastases on short-tau inversion recovery (STIR) and diffusion-weighted MRI (DWI) whole-body MR sequences for breast, prostate and myeloma malignancies. METHODS: 44 whole-body MRI scans were reviewed retrospectively (coronal T(1) weighted, STIR and DWI with b=800). On each scan, up to four of the largest bone lesions were identified on T(1) weighting, and the region of interest signal intensity was measured on STIR and DWI, as well as the background signal intensity. The mean lesion signal to background ratio was calculated for each patient and then for each malignancy group. RESULTS: In prostate cancer patients, the DWI signal/background ratio was greater than that of STIR in 22 out of 24 patients (mean DWI lesion/background ratio 3.91, mean STIR lesion/background ratio 2.31; p=0.0001). In multiple myeloma, the DWI ratio was higher in 6/7 patients (DWI group mean ratio 7.59, STIR group mean ratio 3.7; p=0.0366). In 13 breast cancer patients, mean STIR and DWI signal/background were similar (DWI group mean ratio 4.13, group mean STIR ratio 4.26; p=0.8587). CONCLUSION: Bone lesion conspicuity measured by lesion/background signal intensity was higher on DWI b=800 than on STIR in patients with prostate cancer and multiple myeloma. DWI should be used in whole-body MR oncology protocols in these conditions to maximise lesion detection.


Assuntos
Neoplasias Ósseas/secundário , Neoplasias da Mama , Imageamento por Ressonância Magnética/métodos , Mieloma Múltiplo , Neoplasias da Próstata , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Imagem Corporal Total/métodos
14.
J Bone Joint Surg Br ; 94(3): 334-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22371539

RESUMO

We carried out a prospective investigation into the radiological outcomes of uncemented Oxford medial compartment unicondylar replacement in 220 consecutive patients (231 knees) performed in a single centre with a minimum two-year follow-up. The functional outcomes using the mean Oxford knee score and the mean high-activity arthroplasty score were significantly improved over the pre-operative scores (p < 0.001). There were 196 patients with a two-year radiological examination performed under fluoroscopic guidance, aiming to provide images acceptable for analysis of the bone-implant interface. Of the six tibial zones examined on each knee on the anteroposterior radiograph, only three had a partial radiolucent line. All were in the medial aspect of the tibial base plate (zone 1) and all measured < 1 mm. All of these patients were asymptomatic. There were no radiolucent lines seen around the femoral component or on the lateral view. There was one revision for loosening at one year due to initial inadequate seating of the tibial component. These results confirm that the early uncemented Oxford medial unicompartmental compartmental knee replacements were reliable and the incidence of radiolucent lines was significantly decreased compared with the reported results of cemented versions of this implant. These independent results confirm those of the designing centre.


Assuntos
Artroplastia do Joelho/métodos , Osteoartrite do Joelho/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentação , Feminino , Fluoroscopia , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Estudos Prospectivos , Desenho de Prótese , Reoperação , Tíbia/diagnóstico por imagem , Resultado do Tratamento
15.
Inorg Chem ; 51(5): 2821-31, 2012 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-22339288

RESUMO

We use a combination of low temperature, high field magnetic circular dichroism, absorption, and emission spectroscopy with relativistic time-dependent density functional calculations to reveal a subtle interplay between the effects of chemical substitution and spin-orbit coupling (SOC) in a family of iridium(III) complexes. Fluorination at the ortho and para positions of the phenyl group of fac-tris(1-methyl-5-phenyl-3-n-propyl-[1,2,4]triazolyl)iridium(III) cause changes that are independent of whether the other position is fluorinated or protonated. This is demonstrated by a simple linear relationship found for a range of measured and calculated properties of these complexes. Further, we show that the phosphorescent radiative rate, k(r), is determined by the degree to which SOC is able to hybridize T(1) to S(3) and that k(r) is proportional to the inverse fourth power of the energy gap between these excitations. We show that fluorination in the para position leads to a much larger increase of the energy gap than fluorination at the ortho position. Theory is used to trace this back to the fact that fluorination at the para position increases the difference in electron density between the phenyl and triazolyl groups, which distorts the complex further from octahedral symmetry, and increases the energy separation between the highest occupied molecular orbital (HOMO) and the HOMO-1. This provides a new design criterion for phosphorescent iridium(III) complexes for organic optoelectronic applications. In contrast, the nonradiative rate is greatly enhanced by fluorination at the ortho position. This may be connected to a significant redistribution of spectral weight. We also show that the lowest energy excitation, 1A, has almost no oscillator strength; therefore, the second lowest excitation, 2E, is the dominant emissive state at room temperature. Nevertheless the mirror image rule between absorption and emission is obeyed, as 2E is responsible for both absorption and emission at all but very low (<10 K) temperatures.

16.
J Phys Chem A ; 115(26): 7401-5, 2011 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-21574639

RESUMO

We have carried out absorption, time-resolved fluorescence, and fluorescence quantum yield measurements of four new soluble anthracene derivatives. They show natural radiative lifetimes in the range of 2.5-4.4 ns, which is 5-10 times shorter than those reported for unsubstituted anthracene. The 9,10-bis(phenylethynyl)anthracene (BPEA) derivatives show the largest fluorescence transition dipoles, which is attributed to extended π-conjugation between anthracene and phenyls through acetylene linkages. Spin-cast films of the BPEA derivatives show strong fluorescence quenching by weakly emitting low energy excitations, which is attributed to excimer-like traps. Quenching is significantly reduced when bulky dendrons are attached so that they give maximum coverage of the emitting chromophore and prevent their aggregation. The results show that anthracene derivatives can be developed into efficient solution-processable fluorescent emitters for the blue and green spectral regions.

18.
J Chem Phys ; 128(20): 204703, 2008 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-18513038

RESUMO

A detailed study of the photophysics of a family of bisfluorene-cored dendrimers is reported. Polarized time-resolved fluorescence, singlet-singlet exciton annihilation and fluorescence quantum yield measurements were performed and used to understand how the dendron structure affects the light-emitting properties of the materials. The exciton diffusion rate is similar in all films studied. An increase in the nonradiative deactivation rate by nearly one order of magnitude is observed in films of dendrimers with stilbenyl and carbazolyl based dendrons as compared to solutions, whereas the dendrimers with biphenyl and diphenylethylenyl dendrons showed highly efficient emission (photoluminescence quantum yields of 90%) in both solution and the solid state. The results of the materials that show fluorescence quenching can be explained by the presence of quenching sites at a concentration of just a fraction of a percent of all macromolecules. A possible explanation of this quenching is hole transfer from the emissive chromophore to the dendron in a face-to-face geometry. These results are important for the design of efficient blue emitters for optoelectronic applications.

19.
Phys Rev Lett ; 100(1): 017402, 2008 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-18232820

RESUMO

A study of triplet-triplet exciton annihilation and nonradiative decay in films of iridium(III)-centered phosphorescent dendrimers is reported. The average separation of the chromophore was tuned by the molecular structure and also by blending with a host material. It was found that triplet exciton hopping is controlled by electron exchange interactions and can be over 600 times faster than phosphorescence quenching. Nonradiative decay occurs by weak dipole-dipole interactions and is independent of exciton diffusion, except in very thin films (<20 nm) where surface quenching dominates the decay.

20.
J Clin Neurosci ; 12(1): 71-9, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15639418

RESUMO

Symptomatic cervical spinal arteriovenous malformations (AVMs) located on the anterior aspect of the spinal cord are rare and surgical removal of these AVMs presents considerable challenges and risks. Surgical techniques to date have usually been by posterior approach and lateral dissection around the cord or via midline myelotomy, both approaches involving cord manipulation and retraction and in the latter, dissection through the spinal cord. We present two teenage patients with symptomatic anteriorly placed mid to high cervical spinal AVMs and associated aneurysm in which excision of the AVMs and aneurysm was performed by an anterior approach using vertebrectomy/corpectomy. The first case had a small perimedullary glomus-type AVM with an aneurysm on the anterior aspect of the cord at the C3/4 level; excision was performed using a single level vertebrectomy/corpectomy, the patient remaining neurologically intact. The second case had a medium-sized juvenile AVM with an aneurysm, both perimedullary and intramedullary, centred at the C5/6 level; excision was performed using a two-level vertebrectomy/corpectomy with no deterioration in the marked pre-operative tetraparesis, which at long-term follow up had improved and stabilised. Anterior approaches have been recently described for treatment of anteriorly placed cervical arteriovenous fistulas (AVFs) and an intramedullary haemangioblastoma, but not as yet for spinal AVMs. These are the first two reported cases of anteriorly situated cervical AVMs successfully removed surgically by an anterior approach and with good neurological outcomes.


Assuntos
Malformações Arteriovenosas/cirurgia , Doenças Vasculares da Medula Espinal/cirurgia , Procedimentos Cirúrgicos Vasculares , Adolescente , Fístula Arteriovenosa/cirurgia , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/patologia , Criança , Feminino , Humanos , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Masculino , Microcirurgia , Quadriplegia/etiologia , Radiografia , Doenças Vasculares da Medula Espinal/diagnóstico por imagem , Doenças Vasculares da Medula Espinal/patologia , Hemorragia Subaracnóidea/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...