Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 59(11)2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-38004013

RESUMO

Background and Objectives: Herein we used numerical analysis to study different biomechanical behaviors of mandibular bone subjected to 0.6 N, 1.2 N, and 2.4 N orthodontic loads during 0-8 mm periodontal breakdown using the Tresca failure criterion. Additionally, correlations with earlier FEA reports found potential ischemic and resorptive risks. Materials and Methods: Eighty-one models (nine patients) and 243 simulations (intrusion, extrusion, rotation, tipping, and translation) were analyzed. Results: Intrusion and extrusion displayed after 4 mm bone loss showed extended stress display in the apical and middle third alveolar sockets, showing higher ischemic and resorptive risks for 0.6 N. Rotation, translation, and tipping displayed the highest stress amounts, and cervical-third stress with higher ischemic and resorptive risks after 4 mm loss for 0.6 N. Conclusions: Quantitatively, rotation, translation, and tipping are the most stressful movements. All three applied forces produced similar stress-display areas for all movements and bone levels. The stress doubled for 1.2 N and quadrupled for 2.4 N when compared with 0.6 N. The differences between the three loads consisted of the stress amounts displayed in color-coded areas, while their location and extension remained constant. Since the MHP was exceeded, a reduction in the applied force to under 0.6 N (after 4 mm of bone loss) is recommended for reducing ischemic and resorptive risks. The stress-display pattern correlated with horizontal periodontal-breakdown simulations.


Assuntos
Osso Esponjoso , Técnicas de Movimentação Dentária , Humanos , Técnicas de Movimentação Dentária/efeitos adversos , Simulação por Computador , Análise de Elementos Finitos , Ligamento Periodontal
2.
Healthcare (Basel) ; 11(19)2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37830659

RESUMO

This finite elements analysis (FEA) assessed the accuracy of maximum shear stress criteria (Tresca) in the study of orthodontic internal surface resorption and the absorption-dissipation ability of dental tissues. The present study was conducted over eighty-one models totaling 324 simulations with various bone loss levels (0-8 mm), where 0.6 N and 1.2 N were applied in the intrusion, extrusion, rotation, tipping, and translation movements. Tresca criteria displayed localized high-stress areas prone to resorption for all situations, better visible in the dentine component. The internal resorptive risks are less than external ones, seeming to increase with the progression of the periodontal breakdown, especially after 4 mm. The internal and external surface high-stress areas are strictly correlated. The qualitative stress display for both forces was almost similar. The rotation and tipping displayed the highest resorptive risks for the pulp chamber, decreasing with bone loss. The resorptive risks seem to increase along with the progression of periodontal breakdown if the same applied force is kept. The dentine resemblance to ductile based on its high absorption-dissipation ability seems correct. Tresca seems to supply a better predictability of the prone-to-resorption areas than the other failure criteria.

3.
Medicina (Kaunas) ; 59(8)2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37629752

RESUMO

Background and Objectives: This numerical analysis investigated the biomechanical behavior of the mandibular bone as a structure subjected to 0.5 N of orthodontic force during periodontal breakdown. Additionally, the suitability of the five most used failure criteria (Von Mises (VM), Tresca (T), maximum principal (S1), minimum principal (S3), and hydrostatic pressure (HP)) for the study of bone was assessed, and a single criterion was identified for the study of teeth and the surrounding periodontium (by performing correlations with other FEA studies). Materials and Methods: The finite element analysis (FEA) employed 405 simulations over eighty-one mandibular models with variable levels of bone loss (0-8 mm) and five orthodontic movements (intrusion, extrusion, tipping, rotation, and translation). For the numerical analysis of bone, the ductile failure criteria are suitable (T and VM are adequate for the study of bone), with Tresca being more suited. S1, S3, and HP criteria, due to their distinctive design dedicated to brittle materials and liquids/gas, only occasionally correctly described the bone stress distribution. Results: Only T and VM displayed a coherent and correlated gradual stress increase pattern for all five movements and levels of the periodontal breakdown. The quantitative values provided by T and VM were the highest (for each movement and level of bone loss) among all five criteria. The MHP (maximum physiological hydrostatic pressure) was exceeded in all simulations since the mandibular bone is anatomically less vascularized, and the ischemic risks are reduced. Only T and VM displayed a correlated (both qualitative and quantitative) stress increase for all five movements. Both T and VM displayed rotation and translation, closely followed by tipping, as stressful movements, while intrusion and extrusion were less stressful for the mandibular bone. Conclusions: Based on correlations with earlier numerical studies on the same models and boundary conditions, T seems better suited as a single unitary failure criterion for the study of teeth and the surrounding periodontium.


Assuntos
Doenças Ósseas Metabólicas , Osso Esponjoso , Humanos , Análise de Elementos Finitos , Ligamento Periodontal , Mandíbula
4.
Healthcare (Basel) ; 11(10)2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37239733

RESUMO

This Finite Elements Analysis (FEA) assessed the accuracy of Tresca failure criteria (maximum shear stress) for the study of external root resorption. Additionally, the tooth absorption-dissipation ability was assessed. Overall, 81 models of the second mandibular premolar, out of a total of 324 simulations, were involved. Five orthodontic movements (intrusion, extrusion, rotation, translation, and tipping) were simulated under 0.6 N and 1.2 N in a horizontal progressive periodontal breakdown simulation of 0-8 mm. In all simulations, Tresca criteria accurately displayed the localized areas of maximum stress prone to external resorption risks, seeming to be adequate for the study of the resorptive process. The localized areas were better displayed in the radicular dentine-cementum component than in the entire tooth structure. The rotation and translation seem prone to a higher risk of external root resorption after 4 mm of loss. The resorptive risks seem to increase along with the progression of periodontal breakdown if the same amount of applied force is guarded. The localized resorption-prone areas follow the progression of bone loss. The two light forces displayed similar extensions of maximum stress areas. The stress displayed in the coronal dentine decreases along with the progression of bone loss. The absorption-dissipation ability of the tooth is about 87.99-97.99% of the stress.

5.
Artigo em Inglês | MEDLINE | ID: mdl-36901151

RESUMO

Herein Finite elements analysis (FEA) study assesses the adequacy and accuracy of five failure criteria (Von Mises (VM), Tresca, maximum principal (S1), minimum principal (S3), and Hydrostatic pressure) for the study of tooth as a structure (made of enamel, dentin, and cement), along with its stress absorption-dissipation ability. Eighty-one 3D models of the second lower premolar (with intact and 1-8 mm reduced periodontium) were subjected to five orthodontic forces (intrusion, extrusion, tipping, rotation, and translation) of 0.5 N (approx. 50 gf) (in a total of 405 FEA simulations). Only the Tresca and VM criteria showed biomechanically correct stress display during the 0-8 mm periodontal breakdown simulation, while the other three showed various unusual biomechanical stress display. All five failure criteria displayed comparable quantitative stress results (with Tresca and VM producing the highest of all), showing the rotational and translational movements to produce the highest amount of stress, while intrusion and extrusion, the lowest. The tooth structure absorbed and dissipated most of the stress produced by the orthodontic loads (from a total of 0.5 N/50 gf only 0.125 N/12.5 gf reached PDL and 0.01 N/1 gf the pulp and NVB). The Tresca criterion seems to be more accurate than Von Mises for the study of tooth as structure.


Assuntos
Ligamento Periodontal , Técnicas de Movimentação Dentária , Técnicas de Movimentação Dentária/métodos , Estresse Mecânico , Periodonto , Análise de Elementos Finitos , Simulação por Computador , Modelos Biológicos
6.
Artigo em Inglês | MEDLINE | ID: mdl-36767254

RESUMO

This study examines 0.6 N and 1.2 N as the maximum orthodontic force for periodontal ligament (PDL) at multiple levels of periodontal breakdown, and the relationships with the ischemic, necrotic, and resorptive risks. Additionally, this study evaluates if Tresca failure criteria is more adequate for the PDL study. Eighty-one 3D models (from nine patients; nine models/patients) with the 2nd lower premolar and different degrees of bone loss (0-8 mm) where subjected to intrusion, extrusion, rotation, translation, and tipping movements. Tresca shear stress was assessed individually for each movement and bone loss level. Rotation and translation produced the highest PDL stresses, while intrusion and extrusion determined the lowest. Apical and middle third PDL stresses were lower than the cervical stress. In intact periodontium, the amount of shear stress produced by the two investigated forces was lower than the 16 KPa of the maximum physiological hydrostatic pressure (MHP). In reduced periodontium (1-8 mm tissue loss), the apical amount of PDL shear stress was lower than MHP for both applied forces, while cervically for rotation, translation and tipping movements exceeded 16 KPa. Additionally, 1.2 N could be used in intact periodontium (i.e., without risks) and for the reduced periodontium only in the apical and middle third of PDL up to 8 mm of bone loss. However, for avoiding any resorptive risks, in the cervical third of PDL, the rotation, translation, and tipping movements require less than 0.2-0.4 N of force after 4 mm of loss. Tresca seems to be more adequate for the study of PDL than other criteria.


Assuntos
Ligamento Periodontal , Técnicas de Movimentação Dentária , Humanos , Ligamento Periodontal/fisiologia , Análise de Elementos Finitos , Periodonto , Estresse Mecânico , Simulação por Computador , Modelos Biológicos
7.
Artigo em Inglês | MEDLINE | ID: mdl-36673936

RESUMO

This study examines 0.6 N-4.8 N as the maximum orthodontic force to be applied to dental pulp and apical NVB on intact and 1-8 mm reduced periodontal-ligament (PDL), in connection with movement and ischemic, necrotic and resorptive risk. In addition, it examines whether the Tresca finite-element-analysis (FEA) criterion is more adequate for the examination of dental pulp and its apical NVB. Eighty-one (nine patients, with nine models for each patient) anatomically correct models of the periodontium, with the second lower-premolar reconstructed with its apical NVB and dental pulp were assembled, based on X-ray CBCT (cone-beam-computed-tomography) examinations and subjected to 0.6 N, 1.2 N, 2.4 N and 4.8 N of intrusion, extrusion, translation, rotation, and tipping. The Tresca failure criterion was applied, and the shear stress was assessed. Forces of 0.6 N, 1.2 N, and 2.4 N had negligible effects on apical NVB and dental pulp up to 8 mm of periodontal breakdown. A force of 4.8 N was safely applied to apical NVB on the intact periodontium only. Rotation and tipping seemed to be the most invasive movements for the apical NVB. For the dental pulp, only the translation and rotation movements seemed to display a particular risk of ischemia, necrosis, and internal orthodontic-resorption for both coronal (0-8 mm of loss) and radicular pulp (4-8 mm of loss), despite the amount of stress being lower than the MHP. The Tresca failure criterion seems more suitable than other criteria for apical NVB and dental pulp.


Assuntos
Polpa Dentária , Técnicas de Movimentação Dentária , Humanos , Dente Pré-Molar , Polpa Dentária/diagnóstico por imagem , Simulação por Computador , Técnicas de Movimentação Dentária/métodos , Periodonto/diagnóstico por imagem , Análise de Elementos Finitos
8.
Artigo em Inglês | MEDLINE | ID: mdl-36497708

RESUMO

The aim of this study was to biomechanically assess the behavior of apical neuro-vascular bundles (NVB) and dental pulp employing Tresca, Von Mises, Pressure, S1 and S3 failure criterions in a gradual periodontal breakdown under orthodontic movements. Additionally, it was to assess the accuracy of failure criteria, correlation with the maximum hydrostatic pressure (MHP), and the amount of force safe for reduced periodontium. Based on cone-beam computed tomography, 81 3D models of the second lower premolar were subjected to 0.5 N of intrusion, extrusion, rotation, tipping, and translation. A Finite Elements Analysis (FEA) was performed. In intact and reduced periodontium apical NVB, stress (predominant in all criteria) was significantly higher than dental pulp stress, but lower than MHP. VM and Tresca displayed identical results, with added pulpal stress in translation and rotation. S1, S3 and Pressure showed stress in the apical NVB area. 0.5 N seems safe up to 8 mm periodontal breakdown. A clear difference between failure criteria for dental pulp and apical NVB cannot be proved based only on the correlation quantitative results-MHP. Tresca and VM (adequate for ductile materials) showed equivalent results with the lowest amounts of stress. The employed failure criteria must be selected based on the type of material to be analyzed.


Assuntos
Polpa Dentária , Técnicas de Movimentação Dentária , Técnicas de Movimentação Dentária/métodos , Polpa Dentária/diagnóstico por imagem , Estresse Mecânico , Fenômenos Biomecânicos , Modelos Biológicos , Análise de Elementos Finitos
9.
Artigo em Inglês | MEDLINE | ID: mdl-36231719

RESUMO

The accuracy of five failure criterions employed in the study of periodontal ligaments (PDL) during periodontal breakdown under orthodontic movements was assessed. Based on cone-beam computed tomography (CBCT) examinations, nine 3D models of the second lower premolar with intact periodontium were created and individually subjected to various levels of horizontal bone loss. 0.5 N of intrusion, extrusion, rotation, tipping, and translation was applied. A finite Elements Analysis (FEA) was performed, and stresses were quantitatively and qualitatively analyzed. In intact periodontium, Tresca and Von Mises (VM) stresses were lower than maximum physiological hydrostatic pressure (MHP), while maximum principal stress S1, minimum principal stress S3, and pressure were higher. In reduced periodontium, Tresca and VM stresses were lower than MHP for intrusion, extrusion, and the apical third of the periodontal ligament for the other movements. 0.5 N of rotation, translation and tipping induced cervical third stress exceeding MHP. Only Tresca (quantitatively more accurate) and VM are adequate for the study of PDL (resemblance to ductile), being qualitatively similar. A 0.5 N force seems safe in the intact periodontium, and for intrusion and extrusion up to 8 mm bone loss. The amount of force should be reduced to 0.1-0.2 N for rotation, 0.15-0.3 N for translation and 0.2-0.4 N for tipping in 4-8 mm periodontal breakdown. S1, S3, and pressure criteria provided only qualitative results.


Assuntos
Ligamento Periodontal , Técnicas de Movimentação Dentária , Simulação por Computador , Análise de Elementos Finitos , Modelos Biológicos , Ligamento Periodontal/diagnóstico por imagem , Ligamento Periodontal/fisiologia , Periodonto , Estresse Mecânico , Técnicas de Movimentação Dentária/métodos
10.
Am J Orthod Dentofacial Orthop ; 161(2): e127-e135, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34563425

RESUMO

INTRODUCTION: This research aimed to assess qualitatively and quantitatively the overall stress in the periodontal ligament during gradual periodontal breakdown (0-8 mm) under orthodontic movements. Correlations between the applied forces, the level of bone loss, the decrease of force magnitude, and the increase of stress were also assessed. METHODS: On the basis of cone-beam computed tomography examinations (voxel size, 0.075 mm), nine 3-dimensional models of a mandibular second premolar with intact periodontium were created and then individually subjected to various levels of horizontal bone loss. Orthodontic forces (intrusion at 0.2 N; extrusion, rotation, and tipping at 0.6 N; translation at 1.2 N) were applied on the brackets. Finite elements analysis was performed, and von Mises (VM) stresses were quantitatively and qualitatively determined. RESULTS: Rotation and translation induced the highest stress apically and cervically, whereas intrusion determined the lowest. Apical stress was lower than cervical stress. In intact periodontium, VM stress was under maximum hydrostatic pressure (MHP) and maximum tolerable stress (MTS). In reduced periodontium, VM stress was lower apically than MHP, whereas cervically, the rotation, translation, and tipping exceeded MHP. CONCLUSIONS: A force of 1.2 N seemed safe to be used in the intact periodontium. Forces higher than 0.6 N could produce stresses exceeding MHP and MTS endangering the reduced periodontium. VM stress failure criterion (despite its limited use) seemed to be more adequate for accurate quantitative results. An overall correlation between the applied force, VM stress increase, and periodontal breakdown applicable to all 5 movements could not be established. This was possible only for individual movements.


Assuntos
Ligamento Periodontal , Técnicas de Movimentação Dentária , Simulação por Computador , Análise de Elementos Finitos , Humanos , Modelos Biológicos , Ligamento Periodontal/diagnóstico por imagem , Estresse Mecânico , Técnicas de Movimentação Dentária/efeitos adversos
11.
Am J Orthod Dentofacial Orthop ; 159(3): e291-e299, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33487500

RESUMO

INTRODUCTION: This analysis aimed to assess quantitatively and qualitatively the compressive stress (S3) in periodontal ligament in a gradual periodontal breakdown (0-8 mm) under orthodontic movements. Correlations between the applied forces, the level of bone resorption, the decrease of force magnitude, and S3 increase were also conducted. METHODS: On the basis of cone-beam computed tomography examinations (voxel size, 0.075 mm), nine 3-dimensional models of the second mandibular premolar with intact periodontium were created and then individually subjected to various levels of horizontal bone loss. Orthodontic forces (intrusion: 0.2 N; extrusion, rotation, tipping: 0.6 N; translation: 1.2 N) were applied on the brackets. Finite elements analysis was performed, and S3 stresses were quantitatively and qualitatively determined. RESULTS: Translation and rotation induced the highest stress apically and cervically, whereas intrusion determined the lowest. Apical stress was lower than cervical stress. In intact periodontium, only intrusion and extrusion exhibited S3 stresses lower (apically and cervically) than maximum hydrostatic pressure (MHP) and maximum tolerable stress (MTS). In reduced periodontium, S3 stress (except for intrusion) exceeded MHP and MTS. CONCLUSIONS: In reduced periodontium, forces of 0.2 N seems safe to be used. Forces of 0.6-1.2 N may produce stresses exceeding both MTS and MHP, endangering the periodontium. S3 failure criterion (despite its widely use) seems not to be adequate for accurate quantitative results when evaluating the stress in the periodontal ligament while remaining adequate for qualitative results. An overall correlation between the applied force, S3 increase, and periodontal breakdown applicable to all 5 movements could not be established-this was possible only for sole movements.


Assuntos
Ligamento Periodontal , Técnicas de Movimentação Dentária , Simulação por Computador , Tomografia Computadorizada de Feixe Cônico , Análise de Elementos Finitos , Humanos , Modelos Biológicos , Ligamento Periodontal/diagnóstico por imagem , Pressão , Estresse Mecânico , Técnicas de Movimentação Dentária/efeitos adversos
12.
Am J Orthod Dentofacial Orthop ; 155(4): 543-551, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30935609

RESUMO

INTRODUCTION: To evaluate the stress at the apical third of the pulp and neurovascular bundle (NVB) during 5 types of orthodontic movement at different levels of bone loss. Furthermore, correlations among bone loss, orthodontic appliances, and stress increase were assessed. METHODS: Based on cone-beam computed tomography datasets, 10 models of the mandibular second premolar were created. Each of these models was subjected to a gradual horizontal bone loss simulation (0-8 mm). Orthodontic forces of 20 g, 60 g, and 120 g were applied during the finite element analysis (FEA). For each bone loss level, stress values were evaluated with the use of Abaqus at the apical third of the pulp and the NVB. RESULTS: The stress manifested at the apical third of the pulp was smaller than that at the NVB. The highest apical NVB stress was found for rotation (0.000546 N/mm2 for 8 mm bone loss) whereas the lowest stress resulted after translational movements (2.35E-04 MPa for 8 mm bone loss). The FEA showed that Proffit's indicated orthodontic forces did not significantly disturb the pulpal blood flow and damage the apical NVB. Up to a doubling of the NVB stress, bone loss correlated with the force reduction to obtain similar stress levels compared with teeth with no bone loss. CONCLUSIONS: The present findings indicate that the stress manifested at the apical third of the pulp is smaller than that at NVB. Rotational movements induce the highest stress and translational forces develop the lowest stress related to the physiologic capillary blood pressure. Furthermore, in situations with reduced periodontium, lower forces are needed to reach the maximum tolerable stress compared with teeth with intact periodontium.


Assuntos
Polpa Dentária/fisiopatologia , Técnicas de Movimentação Dentária , Adulto , Tomografia Computadorizada de Feixe Cônico , Polpa Dentária/diagnóstico por imagem , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Masculino , Modelos Dentários , Estresse Mecânico , Técnicas de Movimentação Dentária/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...