Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 933: 172690, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38670361

RESUMO

Nitrification is a serious water-quality issue in chloraminated engineered water systems (EWSs). Nitrification is often remediated by a chlorine burn (i.e., a free­chlorine conversion), a short-term switch from chloramination to chlorination in EWSs. Opportunistic pathogens (OPs) are the dominant infectious agents in EWSs. However, the responses of OPs to a chlorine burn are unknown. This study for the first time assessed how a chlorine burn affected OPs in a full-scale EWS. We determined the impact of a 1.5-month chlorine burn on four dominant OPs (Legionella, Mycobacterium, Pseudomonas, and Vermamoeba vermiformis) in a representative full-scale chloraminated EWS in the United States. Legionella and Mycobacterium were the most abundant OPs. In the water main, the summed concentration of the four OPs during the chlorine burn [3.27 ± 1.58 log10(GCN·L-1); GCN: genome or gene copy number] was lower (p ≤ 0.001) than before the burn [4.83 ± 0.50 log10(GCN·L-1)]. After the burn, the summed concentration increased to 4.27 ± 0.68 log10(GCN·L-1), comparable to before the burn (p > 0.05), indicating a transient effect of the chlorine burn in the water main. At the residential sites, the summed concentrations of the four OPs were comparable (p > 0.05) at 5.50 ± 0.84, 5.27 ± 1.44, and 5.08 ± 0.71 log10(GCN·L-1) before, during, and after the chlorine burn, respectively. Therefore, the chlorine burn was less effective in suppressing OP (re)growth in the premise plumbing. The low effectiveness might be due to more significant water stagnation and disinfectant residual decay in the premise plumbing. Indeed, for the entire sampling period, the total chlorine residual concentration in the premise plumbing (1.8 mg Cl2·L-1) was lower than in the water main (2.4 mg Cl2·L-1). Consequently, for the entire sampling period, the summed concentration of the four OPs in the premise plumbing [5.26 ± 1.08 log10(GCN·L-1)] was significantly higher (p < 0.001) than in the water main [4.04 ± 1.25 log10(GCN·L-1)]. In addition, the chlorine burn substantially increased the levels of disinfection by-products (DBPs) in the water main. Altogether, a chlorine burn is transient or even ineffective in suppressing OP (re)growth but raises DBP concentrations in chloraminated EWSs. Therefore, the practice of chlorine burns to control nitrification should be optimized, reconsidered, or even replaced.


Assuntos
Cloraminas , Cloro , Microbiologia da Água , Purificação da Água , Purificação da Água/métodos , Desinfetantes , Halogenação , Qualidade da Água
3.
Microorganisms ; 10(2)2022 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-35208810

RESUMO

Legionella pneumophila (Lp) is an opportunistic pathogen that causes respiratory infections primarily through inhalation of contaminated aerosols. Lp can colonize premise plumbing systems due to favorable growth conditions (e.g., lower disinfectant residual, stagnation, warm temperatures). UV-C light-emitting diodes (UV-C LEDs) are an emerging water treatment technology and have been shown to effectively inactivate waterborne pathogens. In this study, the inactivation of four Lp strains (three clinical sg1, 4, and 6; and one sg1 drinking water (DW) isolate) was evaluated using a UV-C LED collimated beam at three wavelengths (255, 265, and 280 nm) and six fluence rates (0.5-34 mJ/cm2). Exposure to 255 nm resulted in higher log reductions at the lower fluences compared to exposures at 265 and 280 nm. Efficacy testing was also performed using a UV-C LED point-of-entry (POE) flow-through device. Based on the log inactivation curves, at 255 nm, the sg4 and sg6 clinical isolates were more susceptible to inactivation compared to the two sg1 isolates. However, at 265 and 280 nm, the sg1 and sg4 clinical isolates were more resistant to inactivation compared to the sg6 clinical and sg1 DW isolates. Differential log reductions were also observed using the POE device. Results indicate that although UV-C LED disinfection is effective, variations in Lp inactivation, wavelengths, and technology applications should be considered, especially when targeting specific isolates within premise plumbing systems.

4.
Front Microbiol ; 12: 625324, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33967975

RESUMO

Microbial drinking water quality in premise plumbing systems (PPSs) strongly affects public health. Bacterial community structure is the essential aspect of microbial water quality. Studies have elucidated the microbial community structure in cold tap water, while the microbial community structures in hot tap and shower water are poorly understood. We sampled cold tap, hot tap, and shower water from a simulated PPS monthly for 16 consecutive months and assessed the bacterial community structures in those samples via high-throughput sequencing of bacterial 16S rRNA genes. The total relative abundance of the top five most abundant phyla (Proteobacteria, Actinobacteria, Bacteroidetes, Cyanobacteria, and Firmicutes) was greater than 90% among the 24 identified phyla. The most abundant families were Burkholderiaceae, Sphingomonadaceae, unclassified Alphaproteobacteria, unclassified Corynebacteriales, and Mycobacteriaceae. A multiple linear regression suggests that the bacterial community diversity increased with water temperature and the age of the simulated PPS, decreased with total chlorine residual concentration, and had a limited seasonal variation. The bacterial community in hot tap water had significantly lower Shannon and Inverse Simpson diversity indices (p < 0.05) and thus a much lower diversity than those in cold tap and shower water. The paradoxical results (i.e., diversity increased with water temperature, but hot tap water bacterial community was less diverse) were presumably because (1) other environmental factors made hot tap water bacterial community less diverse, (2) the diversity of bacterial communities in all types of water samples increased with water temperature, and (3) the first draw samples of hot tap water could have a comparable or even lower temperature than shower water samples and the second draw samples of cold tap water. In both a three-dimensional Non-metric multidimensional scaling ordination plot and a phylogenetic dendrogram, the samples of cold tap and shower water cluster and are separate from hot tap water samples (p < 0.05). In summary, the bacterial community in hot tap water in the simulated PPS had a distinct structure from and a much lower diversity than those in cold tap and shower water.

5.
Pathogens ; 9(7)2020 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-32668779

RESUMO

Understanding Legionella survival mechanisms within building water systems (BWSs) is challenging due to varying engineering, operational, and water quality characteristics unique to each system. This study aimed to evaluate Legionella, mycobacteria, and free-living amoebae occurrence within a BWS over 18-28 months at six locations differing in plumbing material and potable water age, quality, and usage. A total of 114 bulk water and 57 biofilm samples were analyzed. Legionella culturability fluctuated seasonally with most culture-positive samples being collected during the winter compared to the spring, summer, and fall months. Positive and negative correlations between Legionella and L. pneumophila occurrence and other physiochemical and microbial water quality parameters varied between location and sample types. Whole genome sequencing of 19 presumptive Legionella isolates, from four locations across three time points, identified nine isolates as L. pneumophila serogroup (sg) 1 sequence-type (ST) 1; three as L. pneumophila sg5 ST1950 and ST2037; six as L. feeleii; and one as Ochrobactrum. Results showed the presence of a diverse Legionella population with consistent and sporadic occurrence at four and two locations, respectively. Viewed collectively with similar studies, this information will enable a better understanding of the engineering, operational, and water quality parameters supporting Legionella growth within BWSs.

6.
BMC Microbiol ; 20(1): 66, 2020 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-32213160

RESUMO

BACKGROUND: Francisella tularensis is a fastidious, Gram-negative coccobacillus and is the causative agent of tularemia. To assess viability yet overcome lengthy incubation periods, a culture-based PCR method was used to detect early growth of the lowest possible number of F. tularensis cells. This method utilized a previously developed enhanced F. tularensis growth medium and is based on the change in PCR cycle threshold at the start and end of each incubation. RESULTS: To test method robustness, a virulent Type A1 (Schu4) and B (IN99) strain and the avirulent Live Vaccine Strain (LVS) were incubated with inactivated target cells, humic acid, drinking and well water, and test dust at targeted starting concentrations of 1, 10, and 100 CFU mL- 1 (low, mid, and high, respectively). After 48 h, LVS growth was detected at all targeted concentrations in the presence of 106 inactivated LVS cells; while Schu4 and IN99 growth was detected in the presence of 104 Schu4 or IN99 inactivated cells at the mid and high targets. Early detection of F. tularensis growth was strain and concentration dependent in the presence of fast-growing well water and test dust organisms. In contrast, growth was detected at each targeted concentration by 24 h in humic acid and drinking water for all strains. CONCLUSIONS: Results indicated that the culture-based PCR assay is quick, sensitive, and specific while still utilizing growth as a measure of pathogen viability. This method can circumvent lengthy incubations required for Francisella identification, especially when swift answers are needed during epidemiological investigations, remediation efforts, and decontamination verification.


Assuntos
Técnicas Bacteriológicas/métodos , Meios de Cultura/química , Francisella tularensis/crescimento & desenvolvimento , Vacinas Bacterianas/genética , Vacinas Bacterianas/isolamento & purificação , Francisella tularensis/genética , Francisella tularensis/isolamento & purificação , Substâncias Húmicas/microbiologia , Viabilidade Microbiana , Reação em Cadeia da Polimerase
7.
Appl Environ Microbiol ; 85(7)2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30683743

RESUMO

Building water systems promote the regrowth and survival of opportunistic pathogens, such as Legionella pneumophila, especially within biofilms, where most drinking water microbes reside. However, compared to their planktonic form, disinfection efficacy for the biofilm-associated forms of water-based pathogens is unclear. The aim of this study was to determine the effectiveness of free chlorine and monochloramine in the inactivation of biofilm-associated L. pneumophila strain Philadelphia-1 serogroup 1 (LpP1s1). Mature (1.5- to 2-year-old) drinking water biofilms were developed on copper (Cu) and polyvinyl chloride (PVC) slides within biofilm annular reactors, then colonized with LpP1s1 at approximately 4 log10 CFU cm-2 and exposed to 2 mg liter-1 of free chlorine or monochloramine. Ct (disinfectant concentration × time, expressed as mg min liter-1) inactivation values for 2-, 3-, and 4-log10 reductions of planktonic and biofilm LpP1s1 were determined. For planktonic LpP1s1, free chlorine was more effective at inactivation than was monochloramine treatment, and for biofilm-associated LpP1s1, monochloramine was more effective on Cu biofilms while free chlorine was more effective on PVC biofilms. In contrast to monochloramine, free chlorine treatment of Cu and PVC biofilms, negatively impacted LpP1s1 16S rRNA gene transcript levels and may act synergistically with Cu surfaces to further reduce transcript levels. Moreover, LpP1s1 cells shed from biofilms into the bulk water were more resistant to disinfection than were prepared planktonic LpP1s1 cells. Results from this study indicate that biofilm association, disinfectant type, and substratum play an important role in the survival of Legionella pneumophila in building water systems.IMPORTANCE Microbial regrowth within building water systems are promoted by water stagnation, low disinfectant residual, high surface-to-volume ratio, amenable growth temperatures, and colonization of drinking water biofilms. Moreover, biofilms provide protection from environmental stresses, access to higher levels of nutrients, and opportunities for symbiotic interactions with other microbes. Disinfectant efficacy information is historically based on inactivation of pathogens in their planktonic, free-floating forms. However, due to the ecological importance of drinking water biofilms for pathogen survival, this study evaluated the efficacy of two common disinfectants, free chlorine and monochloramine, on Legionella pneumophila colonizing mature, drinking water biofilms established on copper and PVC surfaces. Results showed that inactivation was dependent on the disinfectant type and biofilm substratum. Overall, this, and other related research, will provide a better understanding of Legionella ecological stability and survival and aid policy makers in the management of exposure risks to water-based pathogens within building water systems.


Assuntos
Biofilmes/efeitos dos fármacos , Cloraminas/farmacologia , Cloro/farmacologia , Cobre , Desinfecção/métodos , Água Potável/microbiologia , Legionella pneumophila/efeitos dos fármacos , Cloreto de Polivinila , Biofilmes/crescimento & desenvolvimento , Contagem de Colônia Microbiana , DNA Bacteriano/isolamento & purificação , Desinfetantes/farmacologia , Legionella pneumophila/genética , Legionella pneumophila/crescimento & desenvolvimento , RNA Ribossômico 16S/genética , Microbiologia da Água , Abastecimento de Água
8.
FEMS Microbiol Lett ; 365(10)2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29566231

RESUMO

Legionella pneumophila (Lp) is ubiquitous in the aquatic environment and can persist within drinking water distribution systems (DWDS) enabling these systems to serve as a potential source of human infections. Bacterial surface charge, deduced from electrophoretic mobility (EPM), is a well-recognized contributor to microorganism mobility, adherence and interactions with their surrounding environment. In this study, the EPM of 32 Lp strains representing serogroup (sg) 1 to 14 were measured, in 9.15 mM KH2PO4 at pH 8, to understand cell surface properties that may influence their occurrence within DWDS. EPM measurements indicated the charge of Lp varied widely between serogroups with five distinct clusters, from least to most negatively charged: (i) sg1 to 3, 5, and 12; (ii) sg6, 8, and 10; (iii) sg9 and 13; (iv) sg7, 11, and 14; and (v) sg4. The EPM of sg1 and 4 strains were pH dependent; however, values were constant between pH 6 and 9, a range typical of drinking water, suggesting that EPM differences between Lp serogroups could impact their survival within DWDS. Understanding the ecological importance of Lp surface properties (e.g. in mobility, colonization, resistance to disinfectants, etc.) within DWDS would aid in mitigation of health risks associated with this water-based pathogen.


Assuntos
Eletroforese/métodos , Legionella pneumophila/química , Legionella pneumophila/isolamento & purificação , Doença dos Legionários/microbiologia , Sorotipagem/métodos , Humanos , Legionella pneumophila/classificação , Filogenia , Sorogrupo , Microbiologia da Água
9.
Microb Biotechnol ; 10(4): 773-788, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28097816

RESUMO

It is unclear how the water-based pathogen, Legionella pneumophila (Lp), and associated free-living amoeba (FLA) hosts change or are changed by the microbial composition of drinking water (DW) biofilm communities. Thus, this study characterized the bacterial community structure over a 7-month period within mature (> 600-day-old) copper DW biofilms in reactors simulating premise plumbing and assessed the impact of temperature and introduction of Lp and its FLA host, Vermamoeba vermiformis (Vv), co-cultures (LpVv). Sequence and quantitative PCR (qPCR) analyses indicated a correlation between LpVv introduction and increases in Legionella spp. levels at room temperature (RT), while at 37°C, Lp became the dominant Legionella spp. qPCR analysis suggested Vv presence may not be directly associated with Lp biofilm growth at RT and 37°C, but may contribute to or be associated with non-Lp legionellae persistence at RT. Two-way PERMANOVA and PCoA revealed that temperature was a major driver of microbiome diversity. Biofilm community composition also changed over the seven-month period and could be associated with significant shifts in dissolved oxygen, alkalinity and various metals in the influent DW. Hence, temperature, biofilm age, DW quality and transient intrusions/amplification of pathogens and FLA hosts may significantly impact biofilm microbiomes and modulate pathogen levels over extended periods.


Assuntos
Biofilmes/crescimento & desenvolvimento , Biota , Água Potável/microbiologia , Água Potável/parasitologia , Legionella pneumophila/crescimento & desenvolvimento , Lobosea/crescimento & desenvolvimento , Temperatura , Cobre , Água Potável/química , Lobosea/microbiologia , Reação em Cadeia da Polimerase em Tempo Real , Oligoelementos
10.
Acta Microbiol Immunol Hung ; 64(1): 17-36, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-27929353

RESUMO

Transmission of Francisella tularensis, the etiologic agent of tularemia, has been associated with various water sources. Survival of many waterborne pathogens within free-living amoeba (FLA) is well documented; however, the role of amoebae in the environmental persistence of F. tularensis is unclear. In this study, axenic FLA cultures of Acanthamoeba castellanii, Acanthamoeba polyphaga, and Vermamoeba vermiformis were each inoculated with virulent strains of F. tularensis (Types A and B), the attenuated live vaccine strain, and Francisella novicida. Experimental parameters included low and high multiplicity of infection and incubation temperatures of 25 and 30 °C for 0-10 days. Francisella spp. survival was enhanced by the presence of FLA; however, bacterial growth and protozoa infectivity were not observed. In contrast, co-infections of A. polyphaga and Legionella pneumophila, used as an amoeba pathogen control, resulted in bacterial proliferation, cytopathic effects, and amoebal lysis. Collectively, even though short-term incubation with FLA was beneficial, the long-term effects on Francisella survival are unknown, especially given the expenditure of available amoebal derived nutrients and the fastidious nature of Francisella spp. These factors have clear implications for the role of FLA in Francisella environmental persistence.


Assuntos
Amoeba/crescimento & desenvolvimento , Francisella/crescimento & desenvolvimento , Água Doce/microbiologia , Água Doce/parasitologia , Amoeba/fisiologia , Legionella pneumophila/crescimento & desenvolvimento , Viabilidade Microbiana , Temperatura
11.
Environ Sci Pollut Res Int ; 24(3): 2326-2336, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27815848

RESUMO

Opportunistic pathogens (OPs) in drinking water, like Legionella spp., mycobacteria, Pseudomonas aeruginosa, and free-living amobae (FLA) are a risk to human health, due to their post-treatment growth in water systems. To assess and manage these risks, it is necessary to understand their variations and environmental conditions for the water routinely used. We sampled premise tap (N cold = 26, N hot = 26) and shower (N shower = 26) waters in a bathroom and compared water temperatures to levels of OPs via qPCR and identified Legionella spp. by 16S ribosomal RNA (rRNA) gene sequencing. The overall occurrence and cell equivalent quantities (CE L-1) of Mycobacterium spp. were highest (100 %, 1.4 × 105), followed by Vermamoeba vermiformis (91 %, 493), Legionella spp. (59 %, 146), P. aeruginosa (14 %, 10), and Acanthamoeba spp. (5 %, 6). There were significant variations of OP's occurrence and quantities, and water temperatures were associated with their variations, especially for Mycobacterium spp., Legionella spp., and V. vermiformis. The peaks observed for Legionella, mainly consisted of Legionella pneumophila sg1 or Legionella anisa, occurred in the temperature ranged from 19 to 49 °C, while Mycobacterium spp. and V. vermiformis not only co-occurred with Legionella spp. but also trended to increase with increasing temperatures. There were higher densities of Mycobacterium in first than second draw water samples, indicating their release from faucet/showerhead biofilm. Legionella spp. were mostly at detectable levels and mainly consisted of L. pneumophila, L. anisa, Legionella donaldsonii, Legionella tunisiensis, and an unknown drinking water isolate based on sequence analysis. Results from this study suggested potential health risks caused by opportunistic pathogens when exposed to warm shower water with low chlorine residue and the use of Mycobacterium spp. as an indicator of premise pipe biofilm and the control management of those potential pathogens.


Assuntos
Biofilmes , Legionella , Temperatura , Banheiros , Acanthamoeba , Cloro , Água Potável , Humanos , Legionella pneumophila , Mycobacterium , Pseudomonas aeruginosa , Microbiologia da Água , Abastecimento de Água
12.
Appl Environ Microbiol ; 81(2): 630-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25381242

RESUMO

Water conservation efforts have focused on gray water (GW) usage, especially for applications that do not require potable water quality. However, there is a need to better understand environmental pathogens and their free-living amoeba (FLA) hosts within GW, given their growth potential in stored gray water. Using synthetic gray water (sGW) we examined three strains of the water-based pathogen Legionella pneumophila and its FLA hosts Acanthamoeba polyphaga, A. castellanii, and Vermamoeba vermiformis. Exposure to sGW for 72 h resulted in significant inhibition (P < 0.0001) of amoebal encystation versus control-treated cells, with the following percentages of cysts in sGW versus controls: A. polyphaga (0.6 versus 6%), A. castellanii (2 versus 62%), and V. vermiformis (1 versus 92%), suggesting sGW induced maintenance of the actively feeding trophozoite form. During sGW exposure, L. pneumophila culturability decreased as early as 5 h (1.3 to 2.9 log10 CFU, P < 0.001) compared to controls (Δ0 to 0.1 log10 CFU) with flow cytometric analysis revealing immediate changes in membrane permeability. Furthermore, reverse transcription-quantitative PCR was performed on total RNA isolated from L. pneumophila cells at 0 to 48 h after sGW incubation, and genes associated with virulence (gacA, lirR, csrA, pla, and sidF), the type IV secretion system (lvrB and lvrE), and metabolism (ccmF and lolA) were all shown to be differentially expressed. These results suggest that conditions within GW may promote interactions between water-based pathogens and FLA hosts, through amoebal encystment inhibition and alteration of bacterial gene expression, thus warranting further exploration into FLA and L. pneumophila behavior in GW systems.


Assuntos
Acanthamoeba/efeitos dos fármacos , Regulação Bacteriana da Expressão Gênica/efeitos dos fármacos , Legionella pneumophila/efeitos dos fármacos , Lobosea/efeitos dos fármacos , Esporos de Protozoários/efeitos dos fármacos , Fatores de Virulência/biossíntese , Acanthamoeba/fisiologia , Citometria de Fluxo , Legionella pneumophila/genética , Lobosea/fisiologia , Reação em Cadeia da Polimerase em Tempo Real , Esporos de Protozoários/crescimento & desenvolvimento , Fatores de Tempo , Microbiologia da Água
13.
J Water Health ; 12(4): 763-71, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25473986

RESUMO

A quantitative polymerase chain reaction assay (115 bp amplicon) specific to Escherichia coli K12 with an ABI(TM) internal control was developed based on sequence data encoding the rfb gene cluster. Assay specificity was evaluated using three E. coli K12 strains (ATCC W3110, MG1655 & DH1), 24 non-K12 E. coli and 23 bacterial genera. The biofilm detection limit was 10(3) colony-forming units (CFU) E. coli K12 mL(-1), but required a modified protocol, which included a bio-blocker Pseudomonas aeruginosa with ethylenediaminetetraacetic acid buffered to pH 5 prior to cell lysis/DNA extraction. The novel protocol yielded the same sensitivity for drinking water biofilms associated with Fe3O4 (magnetite)-coated SiO2 (quartz) grains and biofilm-surface iron corrosion products from a drinking water distribution system. The novel DNA extraction protocol and specific E. coli K12 assay are sensitive and robust enough for detection and quantification within iron drinking water pipe biofilms, and are particularly well suited for studying enteric bacterial interactions within biofilms.


Assuntos
Biofilmes/crescimento & desenvolvimento , DNA Bacteriano/isolamento & purificação , Água Potável/microbiologia , Escherichia coli K12/fisiologia , Ferro/metabolismo , Abastecimento de Água/análise , Corrosão , DNA Bacteriano/genética , Escherichia coli K12/genética , Escherichia coli K12/isolamento & purificação , Limite de Detecção , Dados de Sequência Molecular , Pseudomonas aeruginosa/genética , Pseudomonas aeruginosa/isolamento & purificação , Pseudomonas aeruginosa/fisiologia , Reação em Cadeia da Polimerase em Tempo Real , Análise de Sequência de DNA , Especificidade da Espécie
14.
FEMS Microbiol Ecol ; 88(2): 280-95, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24490699

RESUMO

Drinking water (DW) biofilm communities influence the survival of opportunistic pathogens, yet knowledge about the microbial composition of DW biofilms developed on common in-premise plumbing material is limited. Utilizing 16S and 18S rRNA gene pyrosequencing, this study characterized the microbial community structure within DW biofilms established on unplasticized polyvinyl chloride (uPVC) and copper (Cu) surfaces and the impact of introducing Legionella pneumophila (Lp) and Acanthamoeba polyphaga. Mature (> 1 year old) biofilms were developed before inoculation with sterilized DW (control, Con), Lp, or Lp and A. polyphaga (LpAp). Comparison of uPVC and Cu biofilms indicated significant differences between bacterial (P = 0.001) and eukaryotic (P < 0.01) members attributable to the unique presence of several family taxa: Burkholderiaceae, Characeae, Epistylidae, Goniomonadaceae, Paramoebidae, Plasmodiophoridae, Plectidae, Sphenomonadidae, and Toxariaceae within uPVC biofilms; and Enterobacteriaceae, Erythrobacteraceae, Methylophilaceae, Acanthamoebidae, and Chlamydomonadaceae within Cu biofilms. Introduction of Lp alone or with A. polyphaga had no effect on bacterial community profiles (P > 0.05) but did affect eukaryotic members (uPVC, P < 0.01; Cu, P = 0.001). Thus, established DW biofilms host complex communities that may vary based on substratum matrix and maintain consistent bacterial communities despite introduction of Lp, an environmental pathogen.


Assuntos
Bactérias/classificação , Biofilmes , Água Potável/microbiologia , Acanthamoeba/genética , Acanthamoeba/isolamento & purificação , Acanthamoeba/fisiologia , Bactérias/genética , Bactérias/isolamento & purificação , Biodiversidade , Cobre , Eucariotos/genética , Eucariotos/isolamento & purificação , Legionella pneumophila/fisiologia , Cloreto de Polivinila , RNA Ribossômico 16S/genética , RNA Ribossômico 18S/genética , Engenharia Sanitária , Análise de Sequência de DNA
15.
Int J Hyg Environ Health ; 217(2-3): 219-25, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23706882

RESUMO

Legionella occurrence in premise drinking water (DW) systems contributes to legionellosis outbreaks, especially in the presence of suitable protozoan hosts. This study examined L. pneumophila behavior within DW biofilms grown on copper (Cu) and unplasticized polyvinylchloride (uPVC) surfaces in the presence of Acanthamoeba polyphaga. One year-old DW biofilms were established within six CDC biofilm reactors: three each containing Cu or uPVC coupons. Biofilms were then inoculated with L. pneumophila (uPVC-Lp and Cu-Lp), or L. pneumophila and A. polyphaga (uPVC-Lp/Ap and Cu-Lp/Ap) and compared to sterile water inoculated controls (uPVC- and Cu-Control) over a 4 month period. L. pneumophila appeared more persistent by qPCR within Cu biofilms in the presence of A. polyphaga compared to uPVC biofilms with or without A. polyphaga, but maintained their cultivability in uPVC biofilms compared to Cu biofilms. Also, persistent shedding of L. pneumophila cells (assayed by qPCR) in the effluent water implied colonization of L. pneumophila within Cu-coupon reactors compared to no detection from uPVC-coupon reactor effluent 14 days after inoculation. Hence, L. pneumophila appeared to colonize Cu surfaces more effectively and may be shed from the biofilms at a greater frequency and duration compared to L. pneumophila colonized uPVC surfaces with host amoebae playing a role in L. pneumophila persistence within Cu biofilms.


Assuntos
Biofilmes , Cobre , Água Potável/microbiologia , Legionella pneumophila/crescimento & desenvolvimento , Legionelose/microbiologia , Cloreto de Polivinila , Microbiologia da Água , Acanthamoeba , Contagem de Colônia Microbiana , Humanos , Abastecimento de Água
16.
Microb Ecol ; 66(3): 715-26, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23764733

RESUMO

Hartmannella vermiformis and Acanthamoeba polyphaga are frequently isolated from drinking water and permissive to Legionella pneumophila parasitization. In this study, extracellular factor(s) produced by H. vermiformis and A. polyphaga were assessed for their effects on cultivability of L. pneumophila. Page's amoeba saline (PAS) was used as an encystment medium for H. vermiformis and A. polyphaga monolayers, and the culture supernatants (HvS and ApS, respectively) were assessed against L. pneumophila growth. Compared to PAS and ApS, HvS significantly inhibited L. pneumophila strain Philadelphia-1 (Ph-1) cultivability by 3 log(10) colony forming unit (CFU) mL(-1) after 3 days of exposure compared to <0.5 log(10) CFU mL(-1) reduction of strain Lp02 (P < 0.001). Flow cytometric analysis revealed changes in the percentage and cultivability of three bacterial subpopulations: intact/slightly damaged membrane (ISM), undefined membrane status (UD), and mixed type (MT). After 3 days of HvS exposure, the MT subpopulation decreased significantly (31.6 vs 67.2 %, respectively, P < 0.001), while the ISM and UD subpopulations increased (+26.7 and +6.9 %, respectively) with the ISM subpopulation appearing as viable but nonculturable (VBNC) cells. HvS was separated into two fractions based on molecular weight, with more than 99 % of the L. pneumophila inhibition arising from the <5 kDa fraction (P < 0.001). Liquid chromatography indicated the inhibitory molecule(s) are likely polar and elute from a Novapak C18 column between 6 and 15 min. These results demonstrate that H. vermiformis is capable of extracellular modulation of L. pneumophila cultivability and probably promote the VBNC state for this bacterium.


Assuntos
Antibacterianos/farmacologia , Regulação para Baixo/efeitos dos fármacos , Hartmannella/química , Legionella pneumophila/crescimento & desenvolvimento , Acanthamoeba/química , Acanthamoeba/metabolismo , Acanthamoeba/microbiologia , Antibacterianos/química , Antibacterianos/isolamento & purificação , Antibacterianos/metabolismo , Hartmannella/metabolismo , Hartmannella/microbiologia , Legionella pneumophila/efeitos dos fármacos , Peso Molecular
17.
Environ Sci Pollut Res Int ; 20(9): 6351-66, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23589243

RESUMO

The goal of this study was to characterize microbial eukaryotes over a 12-month period to provide insight into the occurrence of potential bacterial predators and hosts in premise plumbing. Nearly 6,300 partial 18S rRNA gene sequences from 24 hot (36.9-39.0 °C) and cold (6.8-29.1 °C) drinking water samples were analyzed and classified into major eukaryotic groups. Each major group, consisting of free-living amoebae (FLA)/protozoa, algae, copepods, dinoflagellates, fungi, nematodes, and unique uncultured eukaryotic sequences, showed limited diversity dominated by a few distinct populations, which may be characteristic of oligotrophic environments. Changes in the relative abundance of predators such as nematodes, copepods, and FLA appear to be related to temperature and seasonal changes in water quality. Sequences nearly identical to FLA such as Hartmannella vermiformis, Echinamoeba thermarmum, Pseudoparamoeba pagei, Protacanthamoeba bohemica, Platyamoeba sp., and Vannella sp. were obtained. In addition to FLA, various copepods, rotifers, and nematodes have been reported to internalize viral and bacterial pathogens within drinking water systems thus potentially serving as transport hosts; implications of which are discussed further. Increasing the knowledge of eukaryotic occurrence and their relationship with potential pathogens should aid in assessing microbial risk associated with various eukaryotic organisms in drinking water.


Assuntos
Água Potável/parasitologia , Água Potável/normas , Eucariotos/genética , Eucariotos/isolamento & purificação , RNA Ribossômico 18S/genética , Bactérias/genética , Bactérias/isolamento & purificação , Regulação da Expressão Gênica , Humanos , Filogenia , Estações do Ano
18.
Appl Environ Microbiol ; 79(8): 2713-20, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23416998

RESUMO

Copper ions are an effective antimicrobial agent used to control Legionnaires' disease and Pontiac fever arising from institutional drinking water systems. Here, we present data on an alternative bactericidal agent, copper oxide nanoparticles (CuO-NPs), and its efficacy on Legionella pneumophila. In broth cultures, the CuO-NPs caused growth inhibition, which appeared to be concentration and exposure time dependent. The transcriptomic response of L. pneumophila to CuO-NP exposure was investigated by using a whole-genome microarray. The expression of genes involved in metabolism, transcription, translation, DNA replication and repair, and unknown/hypothetical proteins was significantly affected by exposure to CuO-NPs. In addition, expression of 21 virulence genes was also affected by exposure to CuO-NP and further evaluated by quantitative reverse transcription-PCR (qRT-PCR). Some virulence gene responses occurred immediately and transiently after addition of CuO-NPs to the cells and faded rapidly (icmV, icmW, lepA), while expression of other genes increased within 6 h (ceg29, legLC8, legP, lem19, lem24, lpg1689, and rtxA), 12 h (cegC1, dotA, enhC, htpX, icmE, pvcA, and sidF), and 24 h (legP, lem19, and ceg19), but for most of the genes tested, expression was reduced after 24 h of exposure. Genes like ceg29 and rtxA appeared to be the most responsive to CuO-NP exposures and along with other genes identified in this study may prove useful to monitor and manage the impact of drinking water disinfection on L. pneumophila.


Assuntos
Cobre/farmacologia , Expressão Gênica/efeitos dos fármacos , Legionella pneumophila/efeitos dos fármacos , Nanopartículas Metálicas , Antibacterianos/farmacologia , Legionella pneumophila/genética , Legionella pneumophila/metabolismo , Nanopartículas Metálicas/química , Oligoelementos/farmacologia , Transcrição Gênica/efeitos dos fármacos
19.
Appl Environ Microbiol ; 78(6): 2070-2, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22226955

RESUMO

Here we present the first attempt to quantify Legionella pneumophila cell numbers within individual amoeba hosts that may be released into engineered water systems. The maximum numbers of culturable L. pneumophila cells grown within Acanthamoeba polyphaga and Naegleria fowleri were 1,348 (mean, 329) and 385 (mean, 44) CFU trophozoite(-1), respectively.


Assuntos
Acanthamoeba/microbiologia , Carga Bacteriana , Legionella pneumophila/isolamento & purificação , Naegleria fowleri/microbiologia
20.
Water Res ; 46(4): 921-33, 2012 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-22209280

RESUMO

While it is well-established that Legionella are able to colonize engineered water systems, the number of interacting factors contributing to their occurrence, proliferation, and persistence are unclear. This review summarizes current methods used to detect and quantify legionellae as well as the current knowledge of engineered water system characteristics that both favour and promote legionellae growth. Furthermore, the use of quantitative microbial risk assessment (QMRA) models to predict potentially critical human exposures to legionellae are also discussed. Understanding the conditions favouring Legionella occurrence in engineered systems and their overall ecology (growth in these systems/biofilms, biotic interactions and release) will aid in developing new treatment technologies and/or systems that minimize or eliminate human exposure to potentially pathogenic legionellae.


Assuntos
Exposição Ambiental/análise , Legionella/fisiologia , Medição de Risco/métodos , Microbiologia da Água , Poluição da Água/análise , Abastecimento de Água , Humanos , Legionella/crescimento & desenvolvimento , Legionella/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...