Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Forensic Sci ; 60(1): 219-25, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25039407

RESUMO

Modern ballistic helmets defeat penetrating bullets by energy transfer from the projectile to the helmet, producing helmet deformation. This deformation may cause severe injuries without completely perforating the helmet, termed "behind armor blunt trauma" (BABT). As helmets become lighter, the likelihood of larger helmet backface deformation under ballistic impact increases. To characterize the potential for BABT, seven postmortem human head/neck specimens wearing a ballistic protective helmet were exposed to nonperforating impact, using a 9 mm, full metal jacket, 124 grain bullet with velocities of 400-460 m/s. An increasing trend of injury severity was observed, ranging from simple linear fractures to combinations of linear and depressed fractures. Overall, the ability to identify skull fractures resulting from BABT can be used in forensic investigations. Our results demonstrate a high risk of skull fracture due to BABT and necessitate the prevention of BABT as a design factor in future generations of protective gear.


Assuntos
Dispositivos de Proteção da Cabeça , Fratura do Crânio com Afundamento/diagnóstico por imagem , Fratura do Crânio com Afundamento/patologia , Fraturas Cranianas/diagnóstico por imagem , Fraturas Cranianas/patologia , Ferimentos por Arma de Fogo/patologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Contusões/patologia , Desenho de Equipamento , Balística Forense , Patologia Legal , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia
2.
Ann Cardiothorac Surg ; 2(6): 814-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24349987

RESUMO

Robotic mitral valve surgery is the most common robotic cardiac procedure performed today. Benefits include smaller, less invasive incisions resulting in less pain, shorter length of hospital stay, improved cosmesis, quicker return to preoperative level of functional activity, and decreased blood transfusion requirements. The history and evolution of robotic mitral valve surgery is detailed in this article. Our institution has performed over 800 robotic mitral valve surgeries, and our technique and outcomes are described. Outcomes and operative times are similar to that for sternotomy and minimally invasive approaches to mitral valve surgery. The benefits and limitations of robotic mitral valve surgery are compared with conventional approaches, and future directions are also discussed.

4.
Rambam Maimonides Med J ; 4(3): e0017, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23908867

RESUMO

Robotic cardiac operations evolved from minimally invasive operations and offer similar theoretical benefits, including less pain, shorter length of stay, improved cosmesis, and quicker return to preoperative level of functional activity. The additional benefits offered by robotic surgical systems include improved dexterity and degrees of freedom, tremor-free movements, ambidexterity, and the avoidance of the fulcrum effect that is intrinsic when using long-shaft endoscopic instruments. Also, optics and operative visualization are vastly improved compared with direct vision and traditional videoscopes. Robotic systems have been utilized successfully to perform complex mitral valve repairs, coronary revascularization, atrial fibrillation ablation, intracardiac tumor resections, atrial septal defect closures, and left ventricular lead implantation. The history and evolution of these procedures, as well as the present status and future directions of robotic cardiac surgery, are presented in this review.

5.
ASAIO J ; 58(6): 550-3, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23085941

RESUMO

Ventricular assist devices emerged as a widely used modality for treatment of end-stage heart failure; however, despite significant advances, external energy supply remains a problem contributing to significant patient morbidity and potential mortality. One potential solution is using the nuclear radioisotope Plutonium-238 as a power source. Given its very high energy density and long half-life, Plutonium-238 could eventually allow a totally intracorporeal ventricular assist system that lasts for the patient's lifetime. Risks, such as leakage and theft identified decades ago, still remain. However, it is possible that newer technologies could be used to overcome the system complexity and unreliability of the previous generations of nuclear-powered mechanical assist systems. Were it not for the remaining safety risks, Plutonium-238 would be an ideal energy source for this purpose.


Assuntos
Fontes de Energia Elétrica , Coração Auxiliar , Plutônio , Humanos , Plutônio/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...