Clin Imaging ; 49: 89-96, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29190518

RESUMO

PURPOSE: To describe MRI features of multiple Focal Nodular Hyperplasia (FNHs). METHODS: 40 consecutive subjects (37 females, mean age, 38.8years) were included. All studies were independently reviewed. This was an observational study to define the radiological features of multifocal FNH. RESULTS: 130 lesions were evaluated. The majority (88.5%), were peripheral in location. 92.3% lesions were lobulated. Marked enhancement was present in 94.6% lesions. In the portal venous and delayed phase, 46.2% and 47.7% lesions were mildly hyperintense. Central scar was present in 77% lesions. CONCLUSIONS: Distinctive features included predominant subcapsular location and mild hyperintensity in the delayed phase, seen in nearly 50% of FNHs.


Assuntos
Hiperplasia Nodular Focal do Fígado/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem , Estudos Retrospectivos , Adulto Jovem
2.
Abdom Imaging ; 40(6): 1426-31, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25994367

RESUMO

PURPOSE: The purpose of this study is to quantitatively compare the accuracy of spatial registration of Cartesian breath-hold 3D-GRE and non-respiratory-triggered free-breathing radial 3D-GRE images with PET data acquisition on whole-body hybrid MR-PET system. MATERIALS AND METHODS: Eight patients (six men and two women; mean age, 56.6 ± 5.5 years) with nine ablated hepatocellular carcinomas constituted our study population. Spatial coordinates (x, y, z) of the estimated isocenters of the ablated areas were independently determined by two radiologists. Both T1-weighted sequences were performed in the axial plane. Distance between the isocenter of the lesion on PET images and on both T1-weighted images was measured, and misregistration was calculated. Statistical analysis was performed using Student t test. RESULTS: Misalignment values of the hepatic ablation zones between PET and MR images were calculated at 4.94 ± 1.35 mm (reader 1) and 4.89 ± 2.21 mm (reader 2) for Cartesian 3D-GRE sequence, and 2.48 ± 0.65 mm (reader 1) and 2.72 ± 0.44 mm (reader 2) for the radial 3D-GRE sequence, with p values of 0.0011 and 0.0133, respectively. CONCLUSION: Radial 3D-GRE offers improved registration accuracy with PET, supporting the use of this T1-weighted sequence in upper abdominal MR-PET studies.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Abdome/diagnóstico por imagem , Abdome/patologia , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Imagem Corporal Total
3.
Eur Radiol ; 25(12): 3596-605, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25916391

RESUMO

OBJECTIVES: To assess the feasibility of high-resolution 3D-gradient-recalled echo (GRE) fat-suppressed T1-weighted images using controlled aliasing acceleration technique (CAIPIRINHA-VIBE), and compare image quality and lesion detection to standard-resolution 3D-GRE images using conventional acceleration technique (GRAPPA-VIBE). MATERIALS AND METHODS: Eighty-four patients (41 males, 43 females; age range: 14-90 years, 58.8 ± 15.6 years) underwent abdominal MRI at 1.5 T with CAIPIRINHA-VIBE [spatial resolution, 0.76 ± 0.04 mm] and GRAPPA-VIBE [spatial resolution, 1.17 ± 0.14 mm]. Two readers independently reviewed image quality, presence of artefacts, lesion conspicuity, and lesion detection. Kappa statistic was used to assess interobserver agreement. Wilcoxon signed-rank test was used for image qualitative pairwise comparisons. Logistic regression with post-hoc testing was used to evaluate statistical significance of lesions evaluation. RESULTS: Interobserver agreement ranged between 0.45-0.93. Pre-contrast CAIPIRINHA-VIBE showed significantly (p < 0.001) sharper images and lesion conspicuity with decreased residual aliasing, but more noise enhancement and inferior image quality. Post-contrast CAIPIRINHA-VIBE showed significantly (p < 0.001) sharper images and higher lesion conspicuity, with less respiratory motion and residual aliasing artefacts. Inferior fat-suppression was noticeable on CAIPIRINHA-VIBE sequences (p < 0.001). CONCLUSION: High in-plane resolution abdominal 3D-GRE fat-suppressed T1-weighted imaging using controlled-aliasing acceleration technique is feasible and yields sharper images compared to standard-resolution images using standard acceleration, with higher post-contrast image quality and trend for improved hepatic lesions detection. KEY POINTS: • High-resolution imaging of the upper abdomen is clinically feasible using 2D-controlled aliasing acceleration technique. • High-resolution imaging yields significantly sharper images and increased hepatic lesions conspicuity. • High-resolution imaging yields significantly less respiratory motion and residual aliasing artefacts. • Controlled-aliasing offers substantial acquisition-time reduction in patients with breath-holding difficulties.


Assuntos
Abdome/patologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Suspensão da Respiração , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reprodutibilidade dos Testes , Adulto Jovem
4.
Eur J Radiol ; 84(1): 26-32, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25467229

RESUMO

PURPOSE: To investigate the efficacy and adequacy of enhancement employing 0.025 mmol/kg of gadobenate dimeglumine at 1.5 Tesla (T), and to compare the extent of enhancement of this dosage between 1.5T and 3T systems. MATERIALS AND METHODS: Our final population included 116 consecutive patients who underwent 0.025 mmol/kg gadobenate dimeglumine-enhanced abdominal MRI (78 men and 38 women; age, 64.1 ± 13.6 years). Sixty patients underwent imaging at 1.5T and 56 patients underwent imaging at 3T. Abdominal enhancement was evaluated qualitatively and quantitatively. The quality of enhancement was compared using Mann-Whitney U test. The percentage of enhancement of each organ was compared using Student t-test. RESULTS: The mean quality rating of enhancement was at least "good" in all phases of enhancement for both 1.5T and 3T. There was a non-significant trend to higher mean ratings at 3T. The liver showed a 1.3-fold higher arterial-phase percentage of enhancement at 3T (p=0.0138). There were no differences between the mean relative enhancement of the pancreas and aorta throughout all phases of enhancement. The percentage of enhancement of the renal cortex was significantly higher at 3T (p<0.0001 to p=0.0293). CONCLUSION: A dose of 0.025 mmol/kg of gadobenate dimeglumine demonstrates diagnostic enhancement in the majority of patients at 1.5T, without significant differences on qualitative evaluation compared to 3T.


Assuntos
Meios de Contraste , Taxa de Filtração Glomerular , Interpretação de Imagem Assistida por Computador/métodos , Rim/metabolismo , Hepatopatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Pancreatopatias/diagnóstico , Abdome/patologia , Adulto , Meios de Contraste/metabolismo , Feminino , Humanos , Aumento da Imagem/métodos , Hepatopatias/patologia , Estudos Longitudinais , Masculino , Meglumina/metabolismo , Pessoa de Meia-Idade , Compostos Organometálicos/metabolismo , Pancreatopatias/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
5.
World J Gastroenterol ; 20(40): 14760-77, 2014 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-25356038

RESUMO

Magnetic resonance (MR) imaging plays an important role in the diagnosis and staging of acute and chronic pancreatitis and may represent the best imaging technique in the setting of pancreatitis due to its unmatched soft tissue contrast resolution as well as non-ionizing nature and higher safety profile of intravascular contrast media, making it particularly valuable in radiosensitive populations such as pregnant patients, and patients with recurrent pancreatitis requiring multiple follow-up examinations. Additional advantages include the ability to detect early forms of chronic pancreatitis and to better differentiate adenocarcinoma from focal chronic pancreatitis. This review addresses new trends in clinical pancreatic MR imaging emphasizing its role in imaging all types of acute and chronic pancreatitis, pancreatitis complications and other important differential diagnoses that mimic pancreatitis.


Assuntos
Imageamento por Ressonância Magnética , Pancreatite Necrosante Aguda/patologia , Pancreatite Crônica/patologia , Adenocarcinoma/patologia , Colangiopancreatografia por Ressonância Magnética , Diagnóstico Diferencial , Diagnóstico Precoce , Humanos , Neoplasias Pancreáticas/patologia , Pancreatite Necrosante Aguda/complicações , Pancreatite Crônica/complicações , Valor Preditivo dos Testes , Prognóstico
6.
World J Gastrointest Pathophysiol ; 5(3): 252-70, 2014 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-25133027

RESUMO

Pancreatitis is defined as the inflammation of the pancreas and considered the most common pancreatic disease in children and adults. Imaging plays a significant role in the diagnosis, severity assessment, recognition of complications and guiding therapeutic interventions. In the setting of pancreatitis, wider availability and good image quality make multi-detector contrast-enhanced computed tomography (MD-CECT) the most used imaging technique. However, magnetic resonance imaging (MRI) offers diagnostic capabilities similar to those of CT, with additional intrinsic advantages including lack of ionizing radiation and exquisite soft tissue characterization. This article reviews the proposed definitions of revised Atlanta classification for acute pancreatitis, illustrates a wide range of morphologic pancreatic parenchymal and associated peripancreatic changes for different types of acute pancreatitis. It also describes the spectrum of early and late chronic pancreatitis imaging findings and illustrates some of the less common types of chronic pancreatitis, with special emphasis on the role of CT and MRI.

7.
World J Radiol ; 6(8): 544-66, 2014 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-25170393

RESUMO

Over the past two decades, advances in cross-sectional imaging such as computed tomography and magnetic resonance imaging (MRI) have dramatically changed the concept of gastrointestinal imaging. MR is playing an increasing role in the evaluation of gastrointestinal disorders. MRI combines the advantages of excellent soft-tissue contrast, noninvasiveness, functional information and lack of ionizing radiation. Furthermore, recent developments of MRI have led to improved spatial and temporal resolution as well as decreased motion artifacts. In this article we describe the technical aspects of gastrointestinal MRI and present a practical approach for a well-known spectrum of gastrointestinal disease processes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...