Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Gastroenterol ; 98(2): 399-411, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12591061

RESUMO

OBJECTIVE: Endoanal ultrasound identifies anal sphincter anatomy, and evacuation proctography visualizes pelvic floor motion during simulated defecation. These complementary techniques can evaluate obstructed defecation and fecal incontinence. Our aim was to develop a single, nonionizing, minimally invasive modality to image global pelvic floor anatomy and motion. METHODS: We studied six patients with fecal incontinence and seven patients with obstructed defecation. The anal sphincters were imaged with an endoanal magnetic resonance imaging (MRI) coil and endoanal ultrasound (five patients). MR fluoroscopy acquired images every 1.4-2 s, using a modified real-time, T2-weighted, single-shot, fast-spin echo sequence, recording motion as patients squeezed pelvic floor muscles and expelled ultrasound gel; no contrast was added to other pelvic organs. Six patients also had scintigraphic defecography. RESULTS: Endoanal ultrasound and MRI were comparable for imaging defects of the internal and external sphincters. Only MRI revealed puborectalis and/or external sphincter atrophy; four of these patients had fecal incontinence. MR fluoroscopy recorded pelvic floor contraction during squeeze and recorded relaxation during simulated defecation. Corresponding comparisons for angle change and perineal descent during defecation were not significant; only MRI, but not scintigraphy, identified excessive perineal descent in two patients. CONCLUSIONS: Pelvic MRI is a promising single, comprehensive, nonradioactive modality to measure structural and functional pelvic floor disturbances in defecatory disorders. This method may provide insights into mechanisms of normal and disordered pelvic floor function in health and disease.


Assuntos
Defecação/fisiologia , Incontinência Fecal/diagnóstico , Imageamento por Ressonância Magnética , Adolescente , Adulto , Idoso , Canal Anal/diagnóstico por imagem , Canal Anal/fisiopatologia , Constipação Intestinal/patologia , Constipação Intestinal/fisiopatologia , Defecografia , Eletromiografia , Incontinência Fecal/fisiopatologia , Feminino , Humanos , Manometria , Pessoa de Meia-Idade , Diafragma da Pelve/patologia , Ultrassonografia
2.
Magn Reson Med ; 45(4): 653-61, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11283994

RESUMO

While spoiled gradient echo sequences provide a rapid means of acquiring T(1)-weighted images, it is often desirable that the magnetization be in the steady state to avoid artifacts. For some applications, this requires many "dummy" repetitions of the pulse sequence prior to data collection, delaying image acquisition. A method is presented in which a saturation pulse, followed by a prescribed recovery period, places longitudinal magnetization levels of all materials near steady state, ready for data acquisition much sooner than when employing only dummy repetitions to achieve steady state. Effects of transverse coherences are studied using configuration theory. The method is shown to be effective in both phantom studies and in vivo applications, including real-time imaging, multiphase cardiac imaging, and triggered contrast-enhanced angiography. Magn Reson Med 45:653-661, 2001.


Assuntos
Imageamento por Ressonância Magnética/métodos , Humanos , Imagens de Fantasmas
3.
Magn Reson Med ; 44(3): 339-48, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10975883

RESUMO

It is shown that a spin-echo sequence may be used to acquire T(2)-weighted, high-resolution, high-SNR sections at quasi-real-time frame rates for interactive, diagnostic imaging. A single-shot fast spin-echo sequence was designed which employs driven equilibrium to realign transverse magnetization remaining at the final spin echo. Driven equilibrium is shown to improve T(2) contrast at a given TR, or conversely to reduce TR by approximately 1000 msec and thus increase temporal resolution while maintaining a given level of contrast. Wiener demodulation of k-space data prior to reconstruction is shown to reduce blurring caused by T(2)-decay while constraining noise often associated with other inverse filters. Images are continuously acquired, reconstructed, and displayed at rates of one image every one to two seconds, while section position and contrast may be altered interactively. The clinical utility of this method is demonstrated with applications to dynamic pelvic floor imaging and interactive obstetric imaging.


Assuntos
Neoplasias Faciais/diagnóstico , Doenças Fetais/diagnóstico , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Complicações Neoplásicas na Gravidez/diagnóstico , Processamento de Sinais Assistido por Computador , Sistemas Computacionais , Neoplasias Faciais/embriologia , Feminino , Géis/análise , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Modelos Teóricos , Diafragma da Pelve/patologia , Imagens de Fantasmas , Óleos de Plantas/análise , Gravidez , Diagnóstico Pré-Natal , Retocele/diagnóstico , Água/análise
4.
Radiology ; 215(2): 584-93, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10796943

RESUMO

Technical reliability was determined for triggering three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiography with MR fluoroscopy. Technical requirements for high reliability were also identified. Reliability was evaluated in 330 consecutive patient studies of the neck, thorax, abdomen, and pelvis. Contrast material arrival was detected fluoroscopically in 325 of the 330 studies (98.5%), and the 3D sequence was successfully triggered in 321 of 330 studies (97.3%). Fluoroscopic triggering of centrically encoded 3D MR angiographic acquisitions is a highly reliable means of obtaining 3D MR angiograms with high spatial resolution.


Assuntos
Meios de Contraste , Fluoroscopia , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Abdome/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Artefatos , Artérias Carótidas/diagnóstico por imagem , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço/patologia , Pelve/patologia , Artéria Renal/diagnóstico por imagem , Reprodutibilidade dos Testes , Tecnologia Radiológica , Tórax/patologia
5.
Magn Reson Med ; 42(6): 1159-65, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10571939

RESUMO

The purpose of this study was to develop cardiac-gated contrast-enhanced 3D MRA for imaging the coronary arteries of pigs. Each major coronary artery was imaged individually in a single 3D slab in one breathhold. To permit acquisition within a breathhold, a limited number of partitions (12-16) were collected in a single, oblique, thin 3D slab. Typical resolution of the acquisition was 0.8 (X) x 1.6 (Y) x 1.6 (Z) mm. MR fluoroscopic localization was used to establish the 3D double-oblique orientation. Real-time MR fluoroscopy was also used to instantaneously trigger the 3D scan after detection in the aortic root of the intravenously administered contrast bolus. Six pigs were used in the study. Each pig was scanned on two separate days. Images routinely show the majority of the length of the three principal coronary arteries. Magn Reson Med 42:1159-1165, 1999.


Assuntos
Vasos Coronários/anatomia & histologia , Processamento de Imagem Assistida por Computador , Angiografia por Ressonância Magnética/métodos , Animais , Meios de Contraste , Fluoroscopia , Gadolínio DTPA , Suínos
6.
MAGMA ; 8(3): 196-206, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10504048

RESUMO

Although a variety of timing techniques and data acquisition strategies have been used for three-dimensional contrast-enhanced MR angiography, many are still limited by inadequate overall reliability, limited spatial resolution, or complexity. A technique is presented in this work in which contrast arrival is detected in the targeted vasculature in real time using MR fluoroscopy. Upon detection the operator triggers a 3D MR angiographic acquisition which uses an elliptical centric view order. It is shown that the view order intrinsically provides a high degree of venous suppression which in turn allows acquisition times of 30 s or longer, permitting high spatial resolution. The reliability of fluoroscopic triggering in bolus detection is shown to be over 90%. The technique provides high quality contrast-enhanced MR angiograms for many vascular regions.


Assuntos
Meios de Contraste , Fluoroscopia/métodos , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Artérias Carótidas/patologia , Fluoroscopia/instrumentação , Gadolínio , Humanos , Artéria Ilíaca/patologia , Angiografia por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Artéria Renal/patologia , Veias Renais/patologia
7.
Int J Card Imaging ; 15(2): 117-29, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10453411

RESUMO

Although a variety of timing techniques and data acquisition strategies have been used for three-dimensional contrast-enhanced MR angiography, many are still limited by inadequate overall reliability, limited spatial resolution, or complexity. A technique is presented in this work in which contrast arrival is detected in the targetted vasculature in real time using MR fluoroscopy. Upon detection the operator triggers a 3D MR angiographic acquisition which uses an elliptical centric view order. It is shown that the view order intrinsically provides a high degree of venous suppression which in turn allows acquisition times of 30 seconds or longer, permitting high spatial resolution. The reliability of fluoroscopic triggering in bolus detection is shown to be over 90%. The technique provides high quality contrast-enhanced MR angiograms for many vascular regions.


Assuntos
Aumento da Imagem , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares/diagnóstico , Fluoroscopia , Humanos , Reprodutibilidade dos Testes
8.
Magn Reson Med ; 42(1): 69-81, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10398952

RESUMO

A method to tailor the view order to the reconstruction cycle is introduced for real-time MRI. It is well known that view sharing and oversampling central k-space views can improve the temporal resolution of gradient-echo pulse sequences. By ordering phase-encodes to synchronize k-space acquisition with the reconstruction cycle, apparent temporal resolution can match the frame rate with as few as one-fourth of the phase-encodes sampled per reconstruction. Spatial resolution is maintained by periodically updating high spatial frequencies. In addition to apparent temporal resolution, three other criteria for real-time imaging are identified and evaluated: display latency, dispersion, and frame-to-frame consistency. Latency is minimized by ordering views in a reverse-centric manner within each reconstruction interval, sampling high-energy views immediately prior to beginning reconstruction. Dispersion is kept low and consistent by synchronizing acquisition and reconstruction, thus avoiding poorly timed reconstruction instances. Real-time implementation demonstrates pulsatile time-of-flight blood signal enhancement in humans.


Assuntos
Fluoroscopia/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Algoritmos , Velocidade do Fluxo Sanguíneo/fisiologia , Simulação por Computador , Imagem Ecoplanar/instrumentação , Desenho de Equipamento , Análise de Fourier , Humanos , Aumento da Imagem/instrumentação , Imagens de Fantasmas , Fluxo Pulsátil/fisiologia , Sensibilidade e Especificidade
9.
Magn Reson Med ; 41(4): 846-9, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10332863

RESUMO

Magnetic resonance imaging allows significant freedom in selecting the orientation and position of a tomographic section. However, it can nonetheless be challenging to determine quickly and efficiently the correct parameters required to image a targeted anatomic structure that may lie at an oblique angle in the imaging volume. We describe a three-point tool in which a) the user interactively selects three points from an anatomic structure of interest during live MR fluoroscopy; b) adjustments to pulse sequence are calculated to image the tomographic section defined by the three points; and c) the section is then immediately imaged fluoroscopically. The tool allows quick localization of, for example, longitudinal images of specific arterial structures.


Assuntos
Artérias/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Algoritmos , Aorta Torácica/anatomia & histologia , Artérias Carótidas/anatomia & histologia , Fluoroscopia/métodos , Humanos , Rotação , Tomografia
10.
Radiology ; 211(1): 265-73, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10189482

RESUMO

PURPOSE: To obtain high-spatial-resolution, venous-suppressed, contrast material-enhanced, three-dimensional (3D) magnetic resonance (MR) angiograms of the carotid arteries and aortic arch by using an elliptic centric view ordering with MR fluoroscopic triggering. MATERIALS AND METHODS: Forty consecutive patients with cerebrovascular disease in the differential diagnosis were evaluated with fluoroscopically triggered 3D MR angiography (gadoteridol dose range, 0.1-0.3 mmol per kilogram of body weight; mean acquisition time, 40 second +/- 8 [SD]). The contrast-enhanced 3D MR angiograms were evaluated for overall quality, vascular signal intensity, venous suppression, and motion artifact. Twenty patients also underwent two-dimensional (2D) time-of-flight (TOF) MR angiography. The overall quality of the 2D TOF MR angiograms and comparative quality between the 2D TOF and contrast-enhanced 3D MR angiograms were determined. RESULTS: The contrast-enhanced 3D MR angiograms were of excellent or more than adequate quality for diagnosis in 36 of the 40 studies (90%). In 35 of the 38 contrast-enhanced 3D studies in which the contrast material bolus was detected fluoroscopically, the internal jugular vein signal intensity was either not detectable or barely visible. In 18 of the 20 patients who also underwent 2D TOF MR angiography, the quality of the contrast-enhanced 3D MR angiograms was graded as markedly superior or superior. CONCLUSION: Contrast-enhanced, elliptic centric 3D MR angiography with real-time MR fluoroscopic triggering offers high-spatial-resolution images of the carotid arteries and aortic arch with reliable venous suppression.


Assuntos
Artérias Carótidas/patologia , Transtornos Cerebrovasculares/diagnóstico , Angiografia por Ressonância Magnética/métodos , Aorta Torácica/patologia , Meios de Contraste , Feminino , Fluoroscopia , Gadolínio , Compostos Heterocíclicos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...