Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Heart J ; 43(48): 5020-5032, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36124729

RESUMO

AIMS: Post-infarction ventricular septal defect (PIVSD) is a mechanical complication of acute myocardial infarction (AMI) with a poor prognosis. Surgical repair is the mainstay of treatment, although percutaneous closure is increasingly undertaken. METHODS AND RESUTS: Patients treated with surgical or percutaneous repair of PIVSD (2010-2021) were identified at 16 UK centres. Case note review was undertaken. The primary outcome was long-term mortality. Patient groups were allocated based upon initial management (percutaneous or surgical). Three-hundred sixty-two patients received 416 procedures (131 percutaneous, 231 surgery). 16.1% of percutaneous patients subsequently had surgery. 7.8% of surgical patients subsequently had percutaneous treatment. Times from AMI to treatment were similar [percutaneous 9 (6-14) vs. surgical 9 (4-22) days, P = 0.18]. Surgical patients were more likely to have cardiogenic shock (62.8% vs. 51.9%, P = 0.044). Percutaneous patients were substantially older [72 (64-77) vs. 67 (61-73) years, P < 0.001] and more likely to be discussed in a heart team setting. There was no difference in long-term mortality between patients (61.1% vs. 53.7%, P = 0.17). In-hospital mortality was lower in the surgical group (55.0% vs. 44.2%, P = 0.048) with no difference in mortality after hospital discharge (P = 0.65). Cardiogenic shock [adjusted hazard ratio (aHR) 1.97 (95% confidence interval 1.37-2.84), P < 0.001), percutaneous approach [aHR 1.44 (1.01-2.05), P = 0.042], and number of vessels with coronary artery disease [aHR 1.22 (1.01-1.47), P = 0.043] were independently associated with long-term mortality. CONCLUSION: Surgical and percutaneous repair are viable options for management of PIVSD. There was no difference in post-discharge long-term mortality between patients, although in-hospital mortality was lower for surgery.


Assuntos
Infarto Miocárdico de Parede Anterior , Comunicação Interventricular , Infarto do Miocárdio , Humanos , Choque Cardiogênico/etiologia , Assistência ao Convalescente , Resultado do Tratamento , Alta do Paciente , Comunicação Interventricular/cirurgia , Sistema de Registros , Reino Unido/epidemiologia , Estudos Retrospectivos
2.
Ann Intern Med ; 175(1): 101-113, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34807719

RESUMO

BACKGROUND: The 2020 European Society of Cardiology (ESC) guidelines recommend using the 0/1-hour and 0/2-hour algorithms over the 0/3-hour algorithm as the first and second choices of high-sensitivity cardiac troponin (hs-cTn)-based strategies for triage of patients with suspected acute myocardial infarction (AMI). PURPOSE: To evaluate the diagnostic accuracies of the ESC 0/1-hour, 0/2-hour, and 0/3-hour algorithms. DATA SOURCES: PubMed, Embase, Cochrane Central Register of Controlled Trials, Web of Science, and Scopus from 1 January 2011 to 31 December 2020. (PROSPERO: CRD42020216479). STUDY SELECTION: Prospective studies that evaluated the ESC 0/1-hour, 0/2-hour, or 0/3-hour algorithms in adult patients presenting with suspected AMI. DATA EXTRACTION: The primary outcome was index AMI. Twenty unique cohorts were identified. Primary data were obtained from investigators of 16 cohorts and aggregate data were extracted from 4 cohorts. Two independent authors assessed each study for methodological quality. DATA SYNTHESIS: A total of 32 studies (20 cohorts) with 30 066 patients were analyzed. The 0/1-hour algorithm had a pooled sensitivity of 99.1% (95% CI, 98.5% to 99.5%) and negative predictive value (NPV) of 99.8% (CI, 99.6% to 99.9%) for ruling out AMI. The 0/2-hour algorithm had a pooled sensitivity of 98.6% (CI, 97.2% to 99.3%) and NPV of 99.6% (CI, 99.4% to 99.8%). The 0/3-hour algorithm had a pooled sensitivity of 93.7% (CI, 87.4% to 97.0%) and NPV of 98.7% (CI, 97.7% to 99.3%). Sensitivity of the 0/3-hour algorithm was attenuated in studies that did not use clinical criteria (GRACE score <140 and pain-free) compared with studies that used clinical criteria (90.2% [CI, 82.9 to 94.6] vs. 98.4% [CI, 88.6 to 99.8]). All 3 algorithms had similar specificities and positive predictive values for ruling in AMI, but heterogeneity across studies was substantial. Diagnostic performance was similar across the hs-cTnT (Elecsys; Roche), hs-cTnI (Architect; Abbott), and hs-cTnI (Centaur/Atellica; Siemens) assays. LIMITATION: Diagnostic accuracy, inclusion and exclusion criteria, and cardiac troponin sampling time varied among studies. CONCLUSION: The ESC 0/1-hour and 0/2-hour algorithms have higher sensitivities and NPVs than the 0/3-hour algorithm for index AMI. PRIMARY FUNDING SOURCE: National Taiwan University Hospital.


Assuntos
Algoritmos , Biomarcadores/sangue , Infarto do Miocárdio/diagnóstico , Guias de Prática Clínica como Assunto , Triagem/métodos , Troponina/sangue , Diagnóstico Diferencial , Europa (Continente) , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Risco , Sociedades Médicas , Fatores de Tempo
3.
Indian Pacing Electrophysiol J ; 21(3): 174-177, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33607221

RESUMO

The presence of left atrial thrombus is a contraindication to cardioversion or catheter ablation in patients with atrial fibrillation, due to the increased risk of systemic thromboembolism. Management of this situation includes changes in the anticoagulation regimen and repeat imaging tests. Accurate diagnosis of left atrial appendage thrombus is therefore essential but can sometimes be challenging. Multiple imaging modalities may sometimes be required in the setting of anatomical variations of the left atrial appendage and surrounding structures. We present the case of a patient awaiting ablation for atypical atrial flutter, who underwent a transthoracic echocardiogram that showed an echodense, mobile structure within the vicinity of the left atrial appendage, suggesting a possible thrombus. A cardiac CT demonstrated the image to correlate with an epicardial fat pad within the transverse sinus.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...