1.
Med Phys ; 32(6): 1555-65, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16013714

RESUMO

Thermal therapy offers a minimally invasive option for treating benign prostatic hyperplasia (BPH) and localized prostate cancer. In this study we investigated a transurethral ultrasound applicator design utilizing curvilinear, or slightly focused, transducers to heat prostatic tissue rapidly and controllably. The applicator was constructed with two independently powered transducer segments operating at 6.5 MHz and measuring 3.5 mm x 10 mm with a 15 mm radius of curvature across the short axis. The curvilinear applicator was characterized by acoustic efficiency measurements, acoustic beam plots, biothermal simulations of human prostate, ex vivo heating trials in bovine liver, and in vivo heating trials in canine prostate (n=3). Each transducer segment was found to emit a narrow acoustic beam (max width <3 mm), which extended the length of the transducer, with deeper penetration than previously developed planar or sectored tubular transurethral ultrasound applicators. Acoustic and biothermal simulations of human prostate demonstrated three treatment schemes for the curvilinear applicator: single shot (10 W, 60 s) schemes to generate narrow ablation zones (13 x 4 mm, 52 degrees C at the lesion boundary), incremental rotation (10 W, 10 degrees/45 s) to generate larger sector-shaped ablation zones (16 mm x 180 degrees sector), and rotation with variable sonication times (10 W, 10 degrees/15-90 s) to conform the ablation zone to a predefined boundary (9-17 mm x 180 degrees sector, 13 min total treatment time). During in vivo canine prostate experiments, guided by MR temperature imaging, single shot sonications (6 W/transducer, 2-3 min) with the curvilinear applicator ablated 20 degree sections of tissue to the prostate boundary (9-15 mm). Multiple adjacent sonications ("sweeping") ablated large sections of the prostate (180 degrees) by using the MR temperature imaging to adjust the power (4-6.4 W/transducer) and sonication time (30-180 s) at each 10 degrees rotation such that the periphery of the prostate reached 52 degrees C before the next rotation. The conclusion of this study was that the curvilinear applicator produces a narrow and penetrating ultrasound beam that, when combined with image guidance, can provide a precise technique for ablating target regions with a contoured outer boundary, such as the prostate capsule, by rotating in small steps while dynamically adjusting the net applied electrical power and sonication time at each position.


Assuntos
Hipertermia Induzida/métodos , Neoplasias da Próstata/terapia , Terapia por Ultrassom/métodos , Uretra/diagnóstico por imagem , Acústica , Animais , Cães , Temperatura Alta , Humanos , Masculino , Próstata/efeitos da radiação , Neoplasias da Próstata/diagnóstico por imagem , Sonicação , Temperatura , Fatores de Tempo , Ultrassom , Ultrassonografia , Uretra/patologia
2.
Phys Med Biol ; 49(2): 189-204, 2004 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-15083666

RESUMO

Transurethral ultrasound applicators with highly directional energy deposition and rotational control were investigated for precise treatment of benign prostatic hyperplasia (BPH) and adenocarcinoma of the prostate (CaP). Two types of catheter-based applicators were fabricated, using either 90 degrees sectored tubular (3.5 mm OD x 10 mm) or planar transducers (3.5 mm x 10 mm). They were constructed to be MRI compatible, minimally invasive and allow for manual rotation of the transducer array within a 10 mm cooling balloon. In vivo evaluations of the applicators were performed in canine prostates (n = 3) using MRI guidance (0.5 T interventional magnet). MR temperature imaging (MRTI) utilizing the proton resonance frequency shift method was used to acquire multiple-slice temperature overlays in real time for monitoring and guiding the thermal treatments. Post-treatment T1-weighted contrast-enhanced imaging and triphenyl tetrazolium chloride stained tissue sections were used to define regions of tissue coagulation. Single sonications with the 90 degrees tubular applicator (9-15 W, 12 min, 8 MHz) produced coagulated zones covering an 80 degrees wedge of the prostate extending from 1-2 mm outside the urethra to the outer boundary of the gland (16 mm radial coagulation). Single sonications with the planar applicator (15-20 W, 10 min, approximately 8 MHz) generated thermal lesions of approximately 30 degrees extending to the prostate boundary. Multiple sequential sonications (sweeping) of a planar applicator (12 W with eight rotations of 30 degrees each) demonstrated controllable coagulation of a 270 degrees contiguous section of the prostate extending to the capsule boundary. The feasibility of using highly directional transurethral ultrasound applicators with rotational capabilities to selectively coagulate regions of the prostate while monitoring and controlling the treatments with MRTI was demonstrated in this study.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Terapia por Ultrassom/instrumentação , Acústica , Adenocarcinoma/radioterapia , Animais , Cateterismo , Cães , Temperatura Alta , Masculino , Transdutores , Terapia por Ultrassom/métodos