1.
Phys Med Biol ; 58(20): 7081-106, 2013 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-24052021

RESUMO

Kinetic parameters estimated from dynamic (18)F-fluorodeoxyglucose ((18)F-FDG) PET acquisitions have been used frequently to assess brain function in humans. Neglecting partial volume correction (PVC) for a dynamic series has been shown to produce significant bias in model estimates. Accurate PVC requires a space-variant model describing the reconstructed image spatial point spread function (PSF) that accounts for resolution limitations, including non-uniformities across the field of view due to the parallax effect. For ordered subsets expectation maximization (OSEM), image resolution convergence is local and influenced significantly by the number of iterations, the count density, and background-to-target ratio. As both count density and background-to-target values for a brain structure can change during a dynamic scan, the local image resolution may also concurrently vary. When PVC is applied post-reconstruction the kinetic parameter estimates may be biased when neglecting the frame-dependent resolution. We explored the influence of the PVC method and implementation on kinetic parameters estimated by fitting (18)F-FDG dynamic data acquired on a dedicated brain PET scanner and reconstructed with and without PSF modelling in the OSEM algorithm. The performance of several PVC algorithms was quantified with a phantom experiment, an anthropomorphic Monte Carlo simulation, and a patient scan. Using the last frame reconstructed image only for regional spread function (RSF) generation, as opposed to computing RSFs for each frame independently, and applying perturbation geometric transfer matrix PVC with PSF based OSEM produced the lowest magnitude bias kinetic parameter estimates in most instances, although at the cost of increased noise compared to the PVC methods utilizing conventional OSEM. Use of the last frame RSFs for PVC with no PSF modelling in the OSEM algorithm produced the lowest bias in cerebral metabolic rate of glucose estimates, although by less than 5% in most cases compared to the other PVC methods. The results indicate that the PVC implementation and choice of PSF modelling in the reconstruction can significantly impact model parameters.


Assuntos
Encéfalo/anatomia & histologia , Encéfalo/diagnóstico por imagem , Fluordesoxiglucose F18 , Processamento de Imagem Assistida por Computador/métodos , Modelos Biológicos , Tomografia por Emissão de Pósitrons , Algoritmos , Voluntários Saudáveis , Humanos , Cinética , Método de Monte Carlo , Tamanho do Órgão , Imagens de Fantasmas , Razão Sinal-Ruído
2.
Eur Radiol ; 22(8): 1776-88, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22752524

RESUMO

OBJECTIVES: Technical performance evaluation of a human brain PET/MRI system. METHODS: The magnetic field compatible positron emission tomography (PET) insert is based on avalanche photodiode (APD) arrays coupled with lutetium oxyorthosilicate (LSO) crystals and slip-fits into a slightly modified clinical 3-T MRI system. The mutual interference between the two imaging techniques was minimised by the careful design of the hardware to maintain the quality of the B (0) and B (1) field homogeneity. RESULTS: The signal-to-noise ratio (SNR) and the homogeneity of the MR images were minimally influenced by the presence of the PET. Measurements according to the Function Biomedical Informatics Research Network (FBIRN) protocol proved the combined system's ability to perform functional MRI (fMRI). The performance of the PET insert was evaluated according to the National Electrical Manufacturers Association (NEMA) standard. The noise equivalent count rate (NEC) peaked at 30.7 × 10(3) counts/s at 7.3 kBq/mL. The point source sensitivity was greater than 7 %. The spatial resolution in the centre field of view was less than 3 mm. Patient data sets clearly revealed a noticeably good PET and MR image quality. CONCLUSION: PET and MRI phantom tests and first patient data exhibit the device's potential for simultaneous multiparametric imaging. KEY POINTS: • Combination of PET and MRI is a new emerging imaging technology. • Evaluated brain PET/MRI enables uncompromised imaging performance. • PET/MRI aims to provide multiparametric imaging allowing acquisition of morphology and metabolism.


Assuntos
Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Mapeamento Encefálico/métodos , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/métodos , Lutécio/farmacologia , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Silicatos/farmacologia
3.
J Nucl Med ; 52(1): 154-61, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21189415

RESUMO

UNLABELLED: Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MRI data can be used for motion tracking. In this work, a novel algorithm for data processing and rigid-body motion correction (MC) for the MRI-compatible BrainPET prototype scanner is described, and proof-of-principle phantom and human studies are presented. METHODS: To account for motion, the PET prompt and random coincidences and sensitivity data for postnormalization were processed in the line-of-response (LOR) space according to the MRI-derived motion estimates. The processing time on the standard BrainPET workstation is approximately 16 s for each motion estimate. After rebinning in the sinogram space, the motion corrected data were summed, and the PET volume was reconstructed using the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed, and motion estimates were obtained using 2 high-temporal-resolution MRI-based motion-tracking techniques. RESULTS: After accounting for the misalignment between the 2 scanners, perfectly coregistered MRI and PET volumes were reproducibly obtained. The MRI output gates inserted into the PET list-mode allow the temporal correlation of the 2 datasets within 0.2 ms. The Hoffman phantom volume reconstructed by processing the PET data in the LOR space was similar to the one obtained by processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the procedure. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 s and 20 ms, respectively. Motion-deblurred PET images, with excellent delineation of specific brain structures, were obtained using these 2 MRI-based estimates. CONCLUSION: An MRI-based MC algorithm was implemented for an integrated MR-PET scanner. High-temporal-resolution MRI-derived motion estimates (obtained while simultaneously acquiring anatomic or functional MRI data) can be used for PET MC. An MRI-based MC method has the potential to improve PET image quality, increasing its reliability, reproducibility, and quantitative accuracy, and to benefit many neurologic applications.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Algoritmos , Humanos , Interpretação de Imagem Assistida por Computador , Movimento (Física) , Imagens de Fantasmas