BACKGROUND: Intramuscular (IM) injection can increase insulin absorption, causing hypoglycemia. Available needle lengths today are 4-12.7 mm for pens and 6-12.7 mm for syringes. We describe the distance (D) from skin surface to muscle fascia at injection sites for subcutaneous (SC) insulin therapy and recommend needle lengths to reduce IM injection risk. MATERIALS AND METHODS: At two locations in the United States, skin and SC fat thicknesses were measured by ultrasound at the abdomen, arm, thigh, and buttock in diverse adults (body mass index [BMI] range, approximately 19-65 kg/m²) with diabetes (n=341 with one or more paired skin and SC measurement, permitting calculation of D). The natural log of D by body site, BMI, and gender were analyzed using a mixed model to estimate IM risk. RESULTS: D varied significantly by body site, BMI, and gender (each P<0.001), increasing with higher BMI and in women. Median D ranged from 10.9 mm (95% confidence interval, 10.3, 11.6) at the thigh to 16.9 mm (15.9, 18.1) at the buttock. Minimum D was <3 mm at the thigh and <5 mm elsewhere. When inserted 90° without pinch-up, the most commonly used needle worldwide (8 mm) has estimated IM risks of 25% and 9.7%, respectively, in the thigh and abdomen, versus 1.6% and 0.1%, respectively, with a 4 mm needle. A 45° insertion reduces, but does not eliminate, IM risk with longer needles. CONCLUSIONS: Gender, BMI, and body site affect D; when combined with needle length and insertion angle, these factors permit detailed estimates of IM insulin injection risk. Such risk varies across sites, appears greatest at the thigh, is unnecessarily increased with 8 mm and 12.7 mm needles, and is greatly reduced with shorter-length needles and good injection technique.


Assuntos
Complicações do Diabetes/prevenção & controle , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Ferimentos Penetrantes Produzidos por Agulha/prevenção & controle , Segurança do Paciente , Pele/diagnóstico por imagem , Gordura Subcutânea/diagnóstico por imagem , Adiposidade , Adolescente , Adulto , Índice de Massa Corporal , Complicações do Diabetes/induzido quimicamente , Complicações do Diabetes/diagnóstico por imagem , Complicações do Diabetes/epidemiologia , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Doença Iatrogênica/epidemiologia , Doença Iatrogênica/prevenção & controle , Injeções Subcutâneas , Insulina/administração & dosagem , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/lesões , Doenças Musculares/induzido quimicamente , Doenças Musculares/epidemiologia , Doenças Musculares/prevenção & controle , Ferimentos Penetrantes Produzidos por Agulha/diagnóstico por imagem , Ferimentos Penetrantes Produzidos por Agulha/epidemiologia , Sobrepeso/complicações , Sobrepeso/diagnóstico por imagem , Risco , Pele/efeitos dos fármacos , Pele/lesões , Gordura Subcutânea/efeitos dos fármacos , Gordura Subcutânea/lesões , Tela Subcutânea/diagnóstico por imagem , Tela Subcutânea/efeitos dos fármacos , Tela Subcutânea/lesões , Ultrassonografia , Estados Unidos/epidemiologia , Adulto Jovem
2.
Ann Clin Biochem ; 51(Pt 1): 30-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23897107

RESUMO

BACKGROUND: Current sampling and transport conditions of samples in general practice can result in pseudohyperkalaemia. This study was undertaken to determine, in a general practice setting, whether there is any difference in haemolysis obtained when using BD Vacutainer® Rapid Serum Tubes (BD RST) compared with using BD Vacutainer® SST™ II Advance Blood Collection Tubes (BD SSTII). METHODS: Blood was collected from 353 patients requiring blood sampling who were attending 31 general practitioner practices in Belgium. For each patient, two BD SSTII tubes and two BD RST tubes were drawn in a randomized order. One of each pair of tubes was inverted five times, the other was not. Serum potassium concentration, serum LDH activity and haemolysis index were measured in each sample. RESULTS: There was no significant difference in measured potassium concentration according to tube type (P = 0.16). Measured LDH activities were 1.7% higher in serum collected into BD SSTII tubes compared to BD RST tubes (P = 0.02). When comparing serum from unmixed BD RST with BD SSTII tubes, there was a slight reduction in the haemolysis index but no significant difference in measured potassium concentration or LDH activity. Risk of hyperkalaemia was 4.8 times higher in serum from tubes that were incompletely filled compared to those that were filled with the correct amount of blood. CONCLUSION: Both types of blood tubes are suitable for the measurement of serum potassium and LDH in patients from general practice. Tube inversion does not improve the accuracy of either serum potassium or LDH measurement. Blood tubes should be filled to the level recommended by the manufacturer to avoid artefactual increases in measured serum potassium concentration and LDH activity.


Assuntos
Técnicas de Laboratório Clínico , Hiperpotassemia/sangue , L-Lactato Desidrogenase/sangue , Potássio/sangue , Artefatos , Bélgica , Coleta de Amostras Sanguíneas , Eletrólitos , Humanos , Hiperpotassemia/patologia , Flebotomia
3.
Curr Med Res Opin ; 26(6): 1519-30, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20429833

RESUMO

OBJECTIVE: During subcutaneous insulin therapy, inadvertent intramuscular (IM) injections may increase pain and/or adversely affect glucose control. The most appropriate needle length for patients depends on skin thickness (ST) and the distance to muscle fascia. ST and subcutaneous adipose layer thickness (SCT) were measured in adults with diabetes. RESEARCH DESIGN AND METHODS: A total of 388 US adults with diabetes (in three BMI subgroups: <25, 25-29.9, and >or=30 kg/m(2)) with diverse demographic features were evaluated. Each subject had ultrasound measurements of ST and SCT at four injection sites. RESULTS: Subjects had BMI 19.4-64.5 kg/m(2), age 18-85 years; 40% Caucasian, 25% Asian, 16% Black, 14% Hispanic; 28% type 1 diabetes. Mean ST (+/-95% CI) was: arm 2.2 mm (2.2, 2.3), thigh 1.9 mm (1.8, 1.9), abdomen 2.2 mm (2.1, 2.2) and buttocks 2.4 mm (2.4, 2.5). Multivariate analyses showed body site, gender, BMI, and race are statistically significant factors for ST but effects were small. Thigh ST was <0.6 mm thinner than the buttocks. Differences of 10 kg/m(2) account for 0.2 mm ST variation. Mean SCT was: arm 10.8 mm (10.2, 11.3), thigh 10.4 mm (9.8, 10.9), abdomen 13.9 mm (13.2, 17.7) and buttocks 15.4 mm (14.7, 16.2). Females had 5.1 mm greater SCT. Differences of 10 kg/m(2) account for 4 mm SCT variation. ADVERSE EVENTS: A few mild hypo- or hyperglycemia events, unrelated to study procedure, were detected and treated before subject discharge from study visits. LIMITATIONS: Only adults in the US were studied; some measurements could not be obtained on every subject, at every injection site. CONCLUSIONS: Injection site ST does not differ by clinically significant degrees in demographically diverse adults with diabetes; SCT has a wider range. Needles >or=8 mm, inserted perpendicularly, may frequently enter muscle in limbs of males and those with BMI <25 kg/m(2). With 90 degrees insertion, needles 4-5 mm enter the subcutaneous tissue with minimal risk of IM injection in virtually all adults. These data will assist recommending appropriate length needles for subcutaneous insulin injections in adults.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Agulhas , Pele/anatomia & histologia , Gordura Subcutânea/anatomia & histologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Desenho de Equipamento , Feminino , Humanos , Injeções Intradérmicas , Masculino , Pessoa de Meia-Idade , Pele/diagnóstico por imagem , Gordura Subcutânea/diagnóstico por imagem , Ultrassonografia , Estados Unidos , Adulto Jovem