Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Physiol ; 10: 667, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31191358

RESUMO

Integration of technological solutions aims to improve accuracy, precision and repeatability in farming operations, and biosensor devices are increasingly used for understanding basic biology during livestock production. The aim of this study was to design and validate a miniaturized tri-axial accelerometer for non-invasive monitoring of farmed fish with re-programmable schedule protocols. The current device (AE-FishBIT v.1s) is a small (14 mm × 7 mm × 7 mm), stand-alone system with a total mass of 600 mg, which allows monitoring animals from 30 to 35 g onwards. The device was attached to the operculum of gilthead sea bream (Sparus aurata) and European sea bass (Dicentrarchus labrax) juveniles for monitoring their physical activity by measurements of movement accelerations in x- and y-axes, while records of operculum beats (z-axis) served as a measurement of respiratory frequency. Data post-processing of exercised fish in swimming test chambers revealed an exponential increase of fish accelerations with the increase of fish speed from 1 body-length to 4 body-lengths per second, while a close relationship between oxygen consumption (MO2) and opercular frequency was consistently found. Preliminary tests in free-swimming fish kept in rearing tanks also showed that device data recording was able to detect changes in daily fish activity. The usefulness of low computational load for data pre-processing with on-board algorithms was verified from low to submaximal exercise, increasing this procedure the autonomy of the system up to 6 h of data recording with different programmable schedules. Visual observations regarding tissue damage, feeding behavior and circulating levels of stress markers (cortisol, glucose, and lactate) did not reveal at short term a negative impact of device tagging. Reduced plasma levels of triglycerides revealed a transient inhibition of feed intake in small fish (sea bream 50-90 g, sea bass 100-200 g), but this disturbance was not detected in larger fish. All this considered together is the proof of concept that miniaturized devices are suitable for non-invasive and reliable metabolic phenotyping of farmed fish to improve their overall performance and welfare. Further work is underway for improving the attachment procedure and the full device packaging.

2.
Sci Rep ; 8(1): 8512, 2018 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-29855599

RESUMO

Cell microencapsulation is an attractive strategy for cell-based therapies that allows the implantation of genetically engineered cells and the continuous delivery of de novo produced therapeutic products. However, the establishment of a way to retrieve the implanted encapsulated cells in case the treatment needs to be halted or when cells need to be renewed is still a big challenge. The combination of micro and macroencapsulation approaches could provide the requirements to achieve a proper immunoisolation, while maintaining the cells localized into the body. We present the development and characterization of a porous implantable macrocapsule device for the loading of microencapsulated cells. The device was fabricated in polyamide by selective laser sintering (SLS), with controlled porosity defined by the design and the sintering conditions. Two types of microencapsulated cells were tested in order to evaluate the suitability of this device; erythropoietin (EPO) producing C2C12 myoblasts and Vascular Endothelial Growth Factor (VEGF) producing BHK fibroblasts. Results showed that, even if the metabolic activity of these cells decreased over time, the levels of therapeutic protein that were produced and, importantly, released to the media were stable.


Assuntos
Alginatos/química , Células Imobilizadas/citologia , Fibroblastos/citologia , Mioblastos/citologia , Nylons/química , Animais , Cápsulas/química , Sobrevivência Celular , Terapia Baseada em Transplante de Células e Tecidos , Células Imobilizadas/metabolismo , Células Imobilizadas/transplante , Cricetinae , Composição de Medicamentos/métodos , Eritropoetina/metabolismo , Fibroblastos/metabolismo , Fibroblastos/transplante , Camundongos , Mioblastos/metabolismo , Mioblastos/transplante , Porosidade , Impressão Tridimensional , Alicerces Teciduais/química , Fator A de Crescimento do Endotélio Vascular/metabolismo
3.
IEEE Trans Med Imaging ; 33(2): 332-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24108750

RESUMO

The aim of this work is the evaluation of the design for a nonconventional PET scanner, the voxel imaging PET (VIP), based on pixelated room-temperature CdTe detectors yielding a true 3-D impact point with a density of 450 channels/cm(3), for a total 6 336 000 channels in a seamless ring shaped volume. The system is simulated and evaluated following the prescriptions of the NEMA NU 2-2001 and the NEMA NU 4-2008 standards. Results show that the excellent energy resolution of the CdTe detectors (1.6% for 511 keV photons), together with the small voxel pitch (1 × 1 × 2 mm(3)), and the crack-free ring geometry, give the design the potential to overcome the current limitations of PET scanners and to approach the intrinsic image resolution limits set by physics. The VIP is expected to reach a competitive sensitivity and a superior signal purity with respect to values commonly quoted for state-of-the-art scintillating crystal PETs. The system can provide 14 cps/kBq with a scatter fraction of 3.95% and 21 cps/kBq with a scatter fraction of 0.73% according to NEMA NU 2-2001 and NEMA NU 4-2008, respectively. The calculated NEC curve has a peak value of 122 kcps at 5.3 kBq/mL for NEMA NU 2-2001 and 908 kcps at 1.6 MBq/mL for NEMA NU 4-2008. The proposed scanner can achieve an image resolution of ~ 1 mm full-width at half-maximum in all directions. The virtually noise-free data sample leads to direct positive impact on the quality of the reconstructed images. As a consequence, high-quality high-resolution images can be obtained with significantly lower number of events compared to conventional scanners. Overall, simulation results suggest the VIP scanner can be operated either at normal dose for fast scanning and high patient throughput, or at low dose to decrease the patient radioactivity exposure. The design evaluation presented in this work is driving the development and the optimization of a fully operative prototype to prove the feasibility of the VIP concept.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Processamento de Sinais Assistido por Computador , Animais , Compostos de Cádmio , Humanos , Camundongos , Modelos Biológicos , Imagens de Fantasmas , Telúrio
4.
Biosens Bioelectron ; 24(6): 1788-91, 2009 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18823769

RESUMO

A novel and rapid approach to quantify chloride concentration in sweat for early detection of cystic fibrosis (CF) is shown in this work. Disposable screen-printed sensor (SPS) devices capable to induce sweat and measure the chloride concentration are presented. Pilocarpine, which was forced into de skin by means of iontophoresis, has been used to stimulate the sweat glands. Chloride concentration has been directly measured on the skin by potentiometry. The performance of the devices has been tested in synthetic samples, obtaining good agreement with the Nernst equation. Sensors reproducibility has been analyzed in terms of residual standard deviation (RSD), obtaining a value of 8% (n=6 and alpha=0.05). Finally, the application of these sensors in several volunteers has been carried out. The results were compared with the method generally used in hospitals, obtaining deviations minor than 8%.


Assuntos
Técnicas Biossensoriais/instrumentação , Cloretos/análise , Fibrose Cística/diagnóstico , Fibrose Cística/metabolismo , Equipamentos Descartáveis , Eletroquímica/instrumentação , Suor/química , Adulto , Biomarcadores/análise , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
5.
Analyst ; 132(2): 142-7, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17260074

RESUMO

The fabrication, evaluation and attractive performance of multiwall carbon nanotube(MWCNT)/polysulfone biocomposite membrane modified thick-film screen-printed electrochemical biosensors are reported. The fabricated carbon nanotube/polysulfone (CNT/PS) strips combine the attractive advantages of carbon nanotube materials, polysulfone matrix and disposable screen-printed electrodes. Such thick-film carbon nanotubes/polysulfone sensors have a well defined performance, are mechanically stable, and exhibit high electrochemical activity. Furthermore, biocompatibility of CNT/PS composite allows easy incorporation of biological functional moiety of horseradish peroxidase by phase inversion technique. The comparison of graphite with MWCNT as conductor material is described in this paper. The proposed H(2)O(2) biosensor exhibited a linear range (applied potential, -0.2 V) from 0.02 to 0.5 mM and a K(M)(app) of 0.71 mM.


Assuntos
Técnicas Biossensoriais , Eletroquímica/instrumentação , Eletroquímica/métodos , Desenho de Equipamento , Microscopia Eletrônica de Varredura , Nanotubos de Carbono , Polímeros , Sulfonas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...