Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Crit Care ; 27(1): 153, 2023 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-37076861

RESUMO

BACKGROUND: An increase in cardiac index (CI) during an end-expiratory occlusion test (EEOt) predicts fluid responsiveness in ventilated patients. However, if CI monitoring is unavailable or the echocardiographic window is difficult, using the carotid Doppler (CD) could be a feasible alternative to track CI changes. This study investigates whether changes in CD peak velocity (CDPV) and corrected flow time (cFT) during an EEOt were correlated with CI changes and if CDPV and cFT changes predicted fluid responsiveness in patients with septic shock. METHODS: Prospective, single-center study in adults with hemodynamic instability. The CDPV and cFT on carotid artery Doppler and hemodynamic variables from the pulse contour analysis EV1000™ were recorded at baseline, during a 20-s EEOt, and after fluid challenge (500 mL). We defined responders as those who increased CI ≥ 15% after a fluid challenge. RESULTS: We performed 44 measurements in 18 mechanically ventilated patients with septic shock and without arrhythmias. The fluid responsiveness rate was 43.2%. The changes in CDPV were significantly correlated with changes in CI during EEOt (r = 0.51 [0.26-0.71]). A significant, albeit lower correlation, was found for cFT (r = 0.35 [0.1-0.58]). An increase in CI ≥ 5.35% during EEOt predicted fluid responsiveness with 78.9% sensitivity and 91.7% specificity, with an area under the ROC curve (AUROC) of 0.85. An increase in CDPV ≥ 10.5% during an EEOt predicted fluid responsiveness with 96.2% specificity and 53.0% sensitivity with an AUROC of 0.74. Sixty-one percent of CDPV measurements (from - 13.5 to 9.5 cm/s) fell within the gray zone. The cFT changes during EEOt did not accurately predict fluid responsiveness. CONCLUSIONS: In septic shock patients without arrhythmias, an increase in CDPV greater than 10.5% during a 20-s EEOt predicted fluid responsiveness with > 95% specificity. Carotid Doppler combined with EEOt may help optimize preload when invasive hemodynamic monitoring is unavailable. However, the 61% gray zone is a major limitation (retrospectively registered on Clinicaltrials.gov NCT04470856 on July 14, 2020).


Assuntos
Respiração Artificial , Choque Séptico , Adulto , Humanos , Artérias Carótidas , Hidratação , Hemodinâmica , Estudos Prospectivos , Choque Séptico/terapia , Volume Sistólico
2.
Intensive Care Med ; 48(4): 389-413, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35244745

RESUMO

PURPOSE: To assess the ability of clinical examination, blood biomarkers, electrophysiology or neuroimaging assessed within 7 days from return of spontaneous circulation (ROSC) to predict good neurological outcome, defined as no, mild, or moderate disability (CPC 1-2 or mRS 0-3) at discharge from intensive care unit or later, in comatose adult survivors from cardiac arrest (CA). METHODS: PubMed, EMBASE, Web of Science and the Cochrane Database of Systematic Reviews were searched. Sensitivity and specificity for good outcome were calculated for each predictor. The risk of bias was assessed using the QUIPS tool. RESULTS: A total of 37 studies were included. Due to heterogeneities in recording times, predictor thresholds, and definition of some predictors, meta-analysis was not performed. A withdrawal or localisation motor response to pain immediately or at 72-96 h after ROSC, normal blood values of neuron-specific enolase (NSE) at 24 h-72 h after ROSC, a short-latency somatosensory evoked potentials (SSEPs) N20 wave amplitude > 4 µV or a continuous background without discharges on electroencephalogram (EEG) within 72 h from ROSC, and absent diffusion restriction in the cortex or deep grey matter on MRI on days 2-7 after ROSC predicted good neurological outcome with more than 80% specificity and a sensitivity above 40% in most studies. Most studies had moderate or high risk of bias. CONCLUSIONS: In comatose cardiac arrest survivors, clinical, biomarker, electrophysiology, and imaging studies identified patients destined to a good neurological outcome with high specificity within the first week after cardiac arrest (CA).


Assuntos
Parada Cardíaca , Hipotermia Induzida , Adulto , Coma/diagnóstico , Coma/etiologia , Parada Cardíaca/complicações , Parada Cardíaca/terapia , Humanos , Prognóstico , Sobreviventes
3.
Ann Intensive Care ; 10(1): 165, 2020 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-33284392

RESUMO

BACKGROUND: Single-lumen 4Fr or double-lumen 5Fr power injectable peripherally inserted central catheters (PICCs) are not accurate for trans-pulmonary thermodilution (TPTD), since they overestimate cardiac index and other TPTD-derived parameters when compared with centrally inserted central catheters (CICCs) because of the smaller size of their lumen. We hypothesize that PICCs with larger lumen size may be reliable for the cardiac index assessment using the TPTD. METHODS: This is a single-centre, prospective method-comparison study that included adult patients admitted in ICU who required a calibrated Pulse Contour hemodynamic monitoring system (VolumeView/EV1000™) for circulatory shock and had both PICC and CICC in place. We compared TPTD measurements via single-lumen 5Fr or triple-lumen 6Fr polyurethane power injectable PICCs with triple-lumen 7Fr CICC (reference standard). To rule out biases related to manual injection, measurements were repeated using an automated rapid injection system. We performed Bland-Altman analysis accounting for multiple observations per patient. RESULTS: A total of 320 measurements were performed in 15 patients. During the manual phase, the cardiac index measured with either single-lumen 5Fr or triple-lumen 6Fr PICCs were comparable with cardiac index measured with triple-lumen 7Fr CICC (3.2 ± 1.04 vs. 3.2 ± 1.06 L/min/m2, bias 2.2% and 3.3 ± 0.8 vs. 3.0 ± 0.7 L/min/m2, bias 8.5%, respectively). During the automated phase, triple-lumen 6Fr PICC slightly overestimated the cardiac index when compared to triple-lumen 7Fr CICC (CI 3.4 ± 0.7 vs. 3.0 ± 0.7 L/min/m2, bias 12.5%; p = 0.012). For both single-lumen 5Fr and triple-lumen 6Fr PICCs, percentage error vs. triple-lumen 7Fr CICC was below 20% (14.7% and 19% during the manual phase and 14.4% and 13.8% during the automated phase, respectively). Similar results were observed for TPTD-derived parameters. CONCLUSIONS: During hemodynamic monitoring with TPTD, both single-lumen 5Fr PICCs and triple-lumen 6Fr PICCs can be used for cold fluid bolus injection as an alternative to CICC (ClinicalTrials.gov NCT04241926).

4.
Resuscitation ; 156: A80-A119, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33099419

RESUMO

This 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations for advanced life support includes updates on multiple advanced life support topics addressed with 3 different types of reviews. Topics were prioritized on the basis of both recent interest within the resuscitation community and the amount of new evidence available since any previous review. Systematic reviews addressed higher-priority topics, and included double-sequential defibrillation, intravenous versus intraosseous route for drug administration during cardiac arrest, point-of-care echocardiography for intra-arrest prognostication, cardiac arrest caused by pulmonary embolism, postresuscitation oxygenation and ventilation, prophylactic antibiotics after resuscitation, postresuscitation seizure prophylaxis and treatment, and neuroprognostication. New or updated treatment recommendations on these topics are presented. Scoping reviews were conducted for anticipatory charging and monitoring of physiological parameters during cardiopulmonary resuscitation. Topics for which systematic reviews and new Consensuses on Science With Treatment Recommendations were completed since 2015 are also summarized here. All remaining topics reviewed were addressed with evidence updates to identify any new evidence and to help determine which topics should be the highest priority for systematic reviews in the next 1 to 2 years.


Assuntos
Reanimação Cardiopulmonar , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , Adulto , Consenso , Humanos , Parada Cardíaca Extra-Hospitalar/terapia , Revisões Sistemáticas como Assunto
5.
Circulation ; 142(16_suppl_1): S92-S139, 2020 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-33084390

RESUMO

This 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations for advanced life support includes updates on multiple advanced life support topics addressed with 3 different types of reviews. Topics were prioritized on the basis of both recent interest within the resuscitation community and the amount of new evidence available since any previous review. Systematic reviews addressed higher-priority topics, and included double-sequential defibrillation, intravenous versus intraosseous route for drug administration during cardiac arrest, point-of-care echocardiography for intra-arrest prognostication, cardiac arrest caused by pulmonary embolism, postresuscitation oxygenation and ventilation, prophylactic antibiotics after resuscitation, postresuscitation seizure prophylaxis and treatment, and neuroprognostication. New or updated treatment recommendations on these topics are presented. Scoping reviews were conducted for anticipatory charging and monitoring of physiological parameters during cardiopulmonary resuscitation. Topics for which systematic reviews and new Consensuses on Science With Treatment Recommendations were completed since 2015 are also summarized here. All remaining topics reviewed were addressed with evidence updates to identify any new evidence and to help determine which topics should be the highest priority for systematic reviews in the next 1 to 2 years.


Assuntos
Reanimação Cardiopulmonar/normas , Doenças Cardiovasculares/terapia , Serviços Médicos de Emergência/normas , Cuidados para Prolongar a Vida/normas , Adulto , Desfibriladores , Parada Cardíaca/terapia , Humanos , Vasoconstritores/administração & dosagem , Fibrilação Ventricular/terapia
6.
Intensive Care Med ; 46(10): 1803-1851, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32915254

RESUMO

PURPOSE: To assess the ability of clinical examination, blood biomarkers, electrophysiology, or neuroimaging assessed within 7 days from return of spontaneous circulation (ROSC) to predict poor neurological outcome, defined as death, vegetative state, or severe disability (CPC 3-5) at hospital discharge/1 month or later, in comatose adult survivors from cardiac arrest (CA). METHODS: PubMed, EMBASE, Web of Science, and the Cochrane Database of Systematic Reviews (January 2013-April 2020) were searched. Sensitivity and false-positive rate (FPR) for each predictor were calculated. Due to heterogeneities in recording times, predictor thresholds, and definition of some predictors, meta-analysis was not performed. RESULTS: Ninety-four studies (30,200 patients) were included. Bilaterally absent pupillary or corneal reflexes after day 4 from ROSC, high blood values of neuron-specific enolase from 24 h after ROSC, absent N20 waves of short-latency somatosensory-evoked potentials (SSEPs) or unequivocal seizures on electroencephalogram (EEG) from the day of ROSC, EEG background suppression or burst-suppression from 24 h after ROSC, diffuse cerebral oedema on brain CT from 2 h after ROSC, or reduced diffusion on brain MRI at 2-5 days after ROSC had 0% FPR for poor outcome in most studies. Risk of bias assessed using the QUIPS tool was high for all predictors. CONCLUSION: In comatose resuscitated patients, clinical, biochemical, neurophysiological, and radiological tests have a potential to predict poor neurological outcome with no false-positive predictions within the first week after CA. Guidelines should consider the methodological concerns and limited sensitivity for individual modalities. (PROSPERO CRD42019141169).


Assuntos
Parada Cardíaca , Hipotermia Induzida , Adulto , Coma/etiologia , Potenciais Somatossensoriais Evocados , Parada Cardíaca/complicações , Parada Cardíaca/terapia , Humanos , Prognóstico , Sobreviventes
7.
Crit Care Med ; 47(10): 1356-1361, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31356470

RESUMO

OBJECTIVES: Peripherally inserted central catheters are increasingly used in ICU as an alternative to centrally inserted central catheters for IV infusion. However, their reliability for hemodynamic measurements with transpulmonary thermodilution is currently unknown. We investigated the agreement between transpulmonary thermodilution measurements obtained with bolus injection through peripherally inserted central catheter and centrally inserted central catheter (reference standard) using a transpulmonary thermodilution-calibrated Pulse Contour hemodynamic monitoring system (VolumeView/EV1000). DESIGN: Prospective method-comparison study. SETTING: Twenty-bed medical-surgical ICU of a teaching hospital. PATIENTS: Twenty adult ICU patients who required hemodynamic monitoring because of hemodynamic instability and had both peripherally inserted central catheter and centrally inserted central catheter in place. INTERVENTION: The hemodynamic measurements obtained by transpulmonary thermodilution after injection of a cold saline bolus via both centrally inserted central catheter and either a single-lumen 4F or a double-lumen 5F peripherally inserted central catheter using were compared. In order to rule out bias related to manual injection, measurements were repeated using an automated rapid injection system. MEASUREMENTS AND MAIN RESULTS: A total of 320 measurements were made. Cardiac index was significantly higher when measured with double-lumen 5F peripherally inserted central catheter than with centrally inserted central catheter (mean, 4.5 vs 3.3 L/min/m; p < 0.0001; bias, 1.24 L/min/m [0.27, 2.22 L/min/m]; bias percentage, 31%). Global end-diastolic index, extravascular lung water index, and stroke volume index were also overestimated (853 ± 240 vs 688 ± 175 mL/m, 12.2 ± 4.2 vs 9.4 ± 2.9 mL/kg, and 49.6 ± 14.9 vs 39.5 ± 9.6 mL/m, respectively; p < 0.0001). Lower, albeit significant differences were found using single-lumen 4F peripherally inserted central catheter (mean cardiac index, 4.2 vs 3.7 L/min/m; p = 0.043; bias, 0.51 L/min/m [-0.53, 1.55 L/min/m]; bias percentage, 12.7%). All differences were confirmed, even after standardization of bolus speed with automated injection. CONCLUSIONS: Bolus injection through peripherally inserted central catheter for transpulmonary thermodilution using EV1000 led to a significant overestimation of cardiac index, global end-diastolic index, extravascular lung water index, and stroke volume index, especially when double-lumen 5F peripherally inserted central catheter was used (ClinicalTrial.gov NCT03834675).


Assuntos
Débito Cardíaco , Cateterismo Venoso Central/métodos , Idoso , Cateterismo Periférico , Feminino , Monitorização Hemodinâmica/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Termodiluição/métodos
8.
Resuscitation ; 121: 62-70, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29020604

RESUMO

AIMS: To identify the predictors of survival to discharge in adults resuscitated with extracorporeal cardiopulmonary resuscitation (ECPR) following in-hospital cardiac arrest (IHCA). METHODS: MEDLINE and ISI Web of Science were searched for eligible studies. Pooled Odds Ratio (OR) and Pooled Mean Difference (PMD) for each predictor were calculated. The quality of evidence (QOE) was evaluated according to the GRADE guidelines. RESULTS: Eleven studies were included totalling 856 patients. Of these, 324 (37.9%) survived to discharge. Good neurological outcome (Cerebral Performance Category 1 or 2) occurred in 222/263 (84.4%) survivors. Survival was associated with significantly higher odds of an initial shockable rhythm (OR 1.65; 95% confidence interval [95%CI] 1.05-2.61; p=0.03), shorter low-flow time (PMD -17.15 [-20.90, -13.40]min; p<0.00001), lower lactate levels both immediately before ECPR start (PMD -4.12 [-6.0,-2.24]mmol/L; p<0.0001) and on ICU admission (PMD -4.13 [-6.38, -1.88]mmol/L; p<0.0003), lower SOFA score (PMD -1.71 [-2.93, -0.50]; p=0.006) and lower creatinine levels within 24h after ICU admission (PMD -0.37 [-0.54, -0.19]mg/dl; p<0.00001). No significant association was found between survival and age, gender, or cardiac vs. non-cardiac aetiology. The overall QOE was low or very low. CONCLUSIONS: In adult IHCA treated with ECPR a shockable initial rhythm, a lower low-flow time, lower blood lactate levels before ECPR start or on ICU admission, and a lower SOFA score or creatinine levels in the first 24h after ICU admission were associated with a higher likelihood of survival. These factors could help identifying patients who are eligible for ECPR.


Assuntos
Reanimação Cardiopulmonar/mortalidade , Reanimação Cardiopulmonar/métodos , Oxigenação por Membrana Extracorpórea/mortalidade , Parada Cardíaca/mortalidade , Parada Cardíaca/terapia , Adulto , Fatores Etários , Biomarcadores/sangue , Creatinina/análise , Feminino , Humanos , Ácido Láctico/sangue , Masculino , Estudos Observacionais como Assunto , Razão de Chances , Escores de Disfunção Orgânica , Estudos Retrospectivos , Fatores Sexuais , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...