Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 27(9): 1751-3, 2007 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-18051521

RESUMO

The influence of sample test conditions on the NIR veracity was studied with homemade grating diffuse NIR instrument using Yunnan flue-cured tobacco. Deducing analysis error was achieved by model self-emendation when a global NIR model was set up. Without regarding the influence of loading samples and test conditions, the test repetition error, re-loading error and samples tightness error, which were brought by instrument S/N, accounted for 50%, 30% and 20% of the total error, respectively. Depressing sample could reduce errors brought by sample tightness. Changes in test conditions could bring more analysis error, which was larger than the total of repetition error. These results theoretically explain the influence of sample test conditions on the NIR analysis veracity, which can provide basic theory data for farther improvement of homemade instrument and offer a new idea for resolving this problem.


Assuntos
Nicotiana/química , Nicotina/análise , Extratos Vegetais/análise , Espectroscopia de Luz Próxima ao Infravermelho/normas , Carboidratos/análise , Controle de Qualidade , Espectroscopia de Luz Próxima ao Infravermelho/métodos
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 27(9): 1754-6, 2007 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-18051522

RESUMO

The influence of sample annum and the distribution of sample component on NIR veracity was studied with homemade grating diffuse NIR instrument using Yunnan flue-cured tobacco. Results showed that sample annum had an obvious influence on the total sugar and nicotine models, but had an unconspicuous influence on the total-nitrogen model. Models set up by samples, whose component content distribution was normal school, was better than those set up by even distribution. The conclusion in this study has a significant referenced value for the method and principle to select representative samples to modeling from a large amount of specimens.


Assuntos
Nicotiana/química , Nicotina/análise , Extratos Vegetais/análise , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Carboidratos/análise , China , Controle de Qualidade , Fatores de Tempo
3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 27(2): 262-4, 2007 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-17514951

RESUMO

The theory of local partial least square (LPLS) algorithm was described based on locally weighted regression algorithm (LWR). The influence of data processing parameters, such as principal component numbers and local set-up sample number in LPLS mode, on the NIR veracity was studied with homemade grating diffuse NIR instrument using Yunnan flue-cured tobacco. Results showed that for nicotine model, the principal component number decided by cross validation was not the best choice, and better results could be achieved by reducing the principal component number; using 30-50 samples to set up NIR model, the veracity of total sugar, total nitrogen, and nicotine could be improved by 7%, 14% and 10%, respectively. So, LPLS algorithm can effectively improve NIR model's veracity, and is a good method to set up robust NIR models.


Assuntos
Algoritmos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Carboidratos/análise , Análise dos Mínimos Quadrados , Nicotina/análise , Nitrogênio/análise , Nicotiana/química
4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 27(2): 411-3, 2007 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-17514989

RESUMO

The influence of instrument parameters, such as scan internal, length of instrument run, frequency of scan background etc, on NIR veracity was studied with a homemade grating diffuse NIR instrument using Yunnan flue-cured tobacco. Results showed that scan interval, such as 8 nm or 16 nm, had no evident influence on NIR quantitative analysis. To improve scan speed, the scan interval the authors decided to use was 16 nm. NIR model was set up which could revise the influence of the length of instrument run. This instrument can clue on baseline shift to decide the frequency of background scanning, which can deduce NIR analysis error and improve NIR veracity.


Assuntos
Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Difusão , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Nicotiana/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...