Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cancer ; 11(23): 6834-6840, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33123274

RESUMO

Purpose: To investigate the accuracy and the discriminatory performance in the prognostic prediction in breast cancer (BC) patients with ipsilateral supraclavicular lymph node (ISLN) metastasis using the between the American Joint Committee on Cancer (AJCC) 7th and 8th edition staging system. Methods: Female patients diagnosed as BC were retrieved from the Surveillance, Epidemiology, and End Results database between 2010 and 2014. Chi-squared test, Kaplan-Meier method, Cox proportional hazard analysis, and the receiver operating characteristics were used to conduct statistical analysis. Results: We included 1097 BC patients with ISLN metastasis (N3c disease), including 29.4% (n=322) and 70.6% (n=775) of patients with non-metastatic and metastatic stage at diagnosis, respectively. In non-metastatic stage patients, 64.9% of the patients categorized as having stage IIIC disease in the 7th edition AJCC staging system were downstaged to stage IIIA or IIIB according to the 8th AJCC staging criteria. The AJCC 8th edition staging system had better discriminatory prognostic value than the 7th AJCC staging (area under the curve: 0.586 vs. 0.577, P=0.0006), with a 5-year breast cancer-specific survival (BCSS) rate of 71.3%, 62.2%, 45.2% and 39.1% in stage IIIA, IIIB, IIIC, and IV cohorts, respectively (P<0.0001). The multivariate prognostic analysis revealed that the AJCC 8th edition staging system was an independent prognostic factor for BCSS, while no statistical difference in BCSS was found between the 8th AJCC stage IIIC and IV patients (P=0.188). Conclusion: The AJCC 8th edition pathological prognostic staging showed a better discriminatory prognostic value in ISLN-metastasized breast cancer patients. An additional clarification strategy in stage IIIC disease based on the 8th AJCC staging should be developed to differentiate patients who are curable with multimodality therapy and patients who have less benefit from curative treatment.

2.
Zhong Yao Cai ; 39(6): 1247-50, 2016 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-30156794

RESUMO

Objective: To study the relationship between the component content of curcuminoids in Curcumae Longae Rhizoma and powder color indeces L*, a* and b* those were measured by chromaticity instrument, in order to provide scientific basis for quality assessment of Curcuma longa medicinal materials. Methods: Detect the content of curcumin,demethoxycurcumin,bisdemethoxycurcumin,then detect the content of curcuminoids by the Chinese Pharmacopoeia method. Measure the color indeces L*, a* and b* of Curcumae Longae Rhizoma powder by colorimeter. Finally, the relationship between the content and the color was analyzed by using the Grey Relational Analysis, Pearson correlation coefficient and regression analysis. Results: There was positive correlation between the content of curcuminoids and a*. But there was no definitely relation between the content of curcuminoids and b* or L*. Conclusion: The content of curcuminoids is closely related with the degree of the color red, the higher the content, the red is deeper. a* could be recognized as an important basis of Curcumae Longae Rhizoma medicinal materials quality.


Assuntos
Rizoma , Cor , Colorimetria , Curcuma , Curcumina/análogos & derivados , Diarileptanoides , Pós
3.
Zhongguo Zhong Yao Za Zhi ; 40(20): 4022-5, 2015 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-27062821

RESUMO

This research is to establish an HPLC method for the simultaneous determination of ophiopogonin D, ophiopogonin D', ophiopogonin C, deacetylophiopojaponin A and ophiogenin-3-O-α-L-rhamnosyl-(1-->2)-ß-D-glucoside in Ophiopogonis Radix. HPLC-ELSD analysis was performed on a Kromasil 100-5 C18 column (4.6 mm x 250 mm, 5 µm), with the mobile phase of acetonitrile (A) -water (B) in gradient elution mode (0-45 min, 35%-55% A), at a flow rate of 1 mL · min⁻¹. The column temperature was 35 °C and the drift tube temperature was 100 °C in a gas flow rate of 3.0 L · min⁻¹. The result showed that baseline of all the 5 constituents was well separated, and every constituent had wide linearity range and good linear relation (r > 0.999). The recovery rate was between 95.75% and 103.1%. The new established method for simultaneous determination of saponin constituents in Ophiopogonis Radix was sensitive and has good, repeatability. It could be applied to quality evaluation of Ophiopogonis Radix.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Medicamentos de Ervas Chinesas/química , Ophiopogon/química , Saponinas/química , Medicamentos de Ervas Chinesas/isolamento & purificação , Raízes de Plantas/química , Saponinas/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...