Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Ultrasound Obstet Gynecol ; 50(6): 753-760, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28436562

RESUMO

OBJECTIVE: To assess the contribution of fetal magnetic resonance imaging (MRI) in fetuses of the MERIDIAN cohort diagnosed with either agenesis or hypogenesis of the corpus callosum (referred to collectively as failed commissuration) on antenatal ultrasound. METHODS: This was a subgroup analysis of the MERIDIAN study of fetuses with failed commissuration (with or without ventriculomegaly) diagnosed on ultrasound in women who had MRI assessment within 2 weeks of ultrasound and for whom outcome reference data were available. The diagnostic accuracy of ultrasound and MRI was studied, as well as indicators of diagnostic confidence and effects on prognosis/clinical management. Appropriate diagnostic confidence was assessed by the score-based weighted average method, which combines diagnostic accuracy with diagnostic confidence data. RESULTS: In the MERIDIAN cohort, 79 fetuses were diagnosed with failed commissuration on ultrasound (55 with agenesis and 24 with hypogenesis of the corpus callosum). The diagnostic accuracy for detecting failed commissuration was 34.2% for ultrasound and 94.9% for MRI (difference, 60.7% (95% CI, 47.6-73.9%), P < 0.0001). The diagnostic accuracy for detecting hypogenesis of the corpus callosum as a discrete entity was 8.3% for ultrasound and 87.5% for MRI, and for detecting agenesis of the corpus callosum as a distinct entity was 40.0% for ultrasound and 92.7% for MRI. There was a statistically significant improvement in 'appropriate' diagnostic confidence when using MRI as assessed by the score-based weighted average method (P < 0.0001). Prognostic information given to the women changed in 36/79 (45.6%) cases after MRI and its overall effect on clinical management was 'significant', 'major' or 'decisive' in 35/79 cases (44.3%). CONCLUSIONS: Our data suggest that any woman whose fetus has failed commissuration as the only intracranial finding detected on ultrasound should have MRI examination for further evaluation. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Agenesia do Corpo Caloso/diagnóstico por imagem , Corpo Caloso/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ultrassonografia Pré-Natal , Adulto , Agenesia do Corpo Caloso/patologia , Corpo Caloso/anatomia & histologia , Feminino , Idade Gestacional , Humanos , Aumento da Imagem , Gravidez , Prognóstico , Estudos Prospectivos
2.
Ultrasound Obstet Gynecol ; 50(6): 745-752, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28397323

RESUMO

OBJECTIVE: To assess the diagnostic and clinical contribution of fetal magnetic resonance imaging (MRI) in fetuses of the MERIDIAN cohort diagnosed with abnormalities of the posterior fossa as the only intracranial abnormality recognized on antenatal ultrasound. METHODS: This was a subgroup analysis of the MERIDIAN study of fetuses with abnormalities of the posterior fossa (with or without ventriculomegaly) diagnosed on antenatal ultrasound in women who had MRI within 2 weeks of ultrasound and for whom outcome reference data were available. The diagnostic accuracy of ultrasound and MRI is reported, as well as indicators of diagnostic confidence and effects on prognosis and clinical management. Appropriate diagnostic confidence was assessed by the score-based weighted average method, which combines diagnostic accuracy with diagnostic confidence data. RESULTS: Abnormalities confined to the posterior fossa according to ultrasound were found in 81 fetuses (67 with parenchymal and 14 with cerebrospinal fluid-containing lesions). The overall diagnostic accuracy for detecting an isolated posterior fossa abnormality was 65.4% for ultrasound and 87.7% for MRI (difference, 22.3% (95% CI, 14.0-30.5%); P < 0.0001). There was an improvement in 'appropriate' diagnostic confidence, as assessed by the score-based weighted average method (P < 0.0001), and a three-fold reduction in 'high confidence but incorrect diagnosis' was achieved using MRI. Prognostic information given to the women changed after MRI in 44% of cases, and the overall effect of MRI on clinical management was considered to be 'significant', 'major' or 'decisive' in 35% of cases. CONCLUSIONS: Our data suggest that any woman whose fetus has a posterior fossa abnormality as the only intracranial finding on ultrasound should have MRI for further evaluation. This is on the basis of improved diagnostic accuracy and confidence, which impacts substantially on the prognostic information given to women as well as their clinical management. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Fossa Craniana Posterior/anormalidades , Hidrocefalia/diagnóstico , Malformações do Sistema Nervoso/diagnóstico por imagem , Ultrassonografia Pré-Natal , Adulto , Fossa Craniana Posterior/anatomia & histologia , Fossa Craniana Posterior/diagnóstico por imagem , Feminino , Idade Gestacional , Humanos , Hidrocefalia/patologia , Imageamento por Ressonância Magnética , Malformações do Sistema Nervoso/patologia , Gravidez , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes
3.
Ultrasound Obstet Gynecol ; 50(6): 736-744, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28337830

RESUMO

OBJECTIVE: To assess the contribution of fetal magnetic resonance imaging (MRI) in fetuses of the MERIDIAN cohort diagnosed with ventriculomegaly (VM) as the only abnormal intracranial finding on antenatal ultrasound. METHODS: This was a subgroup analysis of the MERIDIAN study of fetuses with only VM diagnosed on ultrasound in women who had a subsequent MRI examination within 2 weeks and for whom outcome reference data were available. The diagnostic accuracy of ultrasound and MRI was reported in relation to the severity of VM. The difference in measurements of trigone size on the two imaging methods and the clinical impact of adding MRI to the diagnostic pathway were also studied. RESULTS: In 306 fetuses with VM, ultrasound failed to detect 31 additional brain abnormalities, having an overall diagnostic accuracy of 89.9% for ultrasound, whilst MRI correctly detected 27 of the additional brain abnormalities, having a diagnostic accuracy of 98.7% (P < 0.0001). There were other brain abnormalities in 14/244 fetuses with mild VM on ultrasound (diagnostic accuracy, 94.3%) and MRI correctly diagnosed 12 of these (diagnostic accuracy, 99.2%; P = 0.0005). There was a close agreement between the size of trigones measured on ultrasound and on MRI, with categorical differences in only 16% of cases, showing that MRI did not systematically overestimate or underestimate trigone size. Complete prognostic data were available in 295/306 fetuses and the prognosis category changed after MRI in 69/295 (23.4%) cases. The overall effect of MRI on clinical management was considered to be 'significant', 'major' or 'decisive' in 76/295 (25.8%) cases. CONCLUSION: Our data suggest that a woman carrying a fetus with VM as the only intracranial finding on ultrasound should be offered an adjuvant investigation by MRI for further evaluation. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Ventrículos Cerebrais/anormalidades , Hidrocefalia/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ultrassonografia Pré-Natal , Adulto , Ventrículos Cerebrais/anatomia & histologia , Ventrículos Cerebrais/patologia , Feminino , Humanos , Hidrocefalia/patologia , Aumento da Imagem , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Reino Unido
4.
Clin Radiol ; 64(5): 473-83, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19348842

RESUMO

AIMS: To investigate the optimal neuroradiological investigation strategy to identify inflicted brain injury (iBI). MATERIALS AND METHODS: A systematic review of studies published between 1970-2008 in any language was conducted, searching 20 databases and four websites, using over 100 keywords/phrases, supplemented by hand-searching of references. All studies underwent two independent reviews (with disagreements adjudicated by a third reviewer) by trained reviewers from paediatrics, paediatric neuroradiology and related disciplines, using standardized critical appraisal tools, and strict inclusion/exclusion criteria. We included primary studies that evaluated the diagnostic yield of magnetic resonance imaging (MRI), in addition to initial computed tomography (CT), or follow-up CT or ultrasound in children with suspected iBI. RESULTS: Of the 320 studies reviewed, 18 met the inclusion criteria, reflecting data on 367 children with iBI and 12 were published since 1998. When an MRI was conducted in addition to an abnormal early CT examination, additional information was found in 25% (95% CI: 18.3-33.16%) of children. The additional findings included further subdural haematoma, subarachnoid haemorrhage, shearing injury, ischaemia, and infarction; it also contributed to dating of injuries. Diffusion-weighted imaging (DWI) further enhanced the delineation of ischaemic changes, and assisted in prognosis. Repeat CT studies varied in timing and quality, and none were compared to the addition of an early MRI/DWI. CONCLUSIONS: In an acutely ill child, the optimal imaging strategy involves initial CT, followed by early MRI and DWI if early CT examination is abnormal, or there are ongoing clinical concerns. The role of repeat CT imaging, if early MRI is performed, is unclear, as is the place for MRI/DWI if initial CT examination is normal in an otherwise well child.


Assuntos
Lesões Encefálicas/diagnóstico , Diagnóstico por Imagem/métodos , Adolescente , Encefalopatias/diagnóstico , Criança , Maus-Tratos Infantis/diagnóstico , Proteção da Criança , Pré-Escolar , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Lactente , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Prognóstico , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos
6.
Clin Radiol ; 62(5): 404-15, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17398264

RESUMO

Unconscious patients are frequently referred to radiology departments for computed tomography (CT) of the brain. The objectives of these examinations are to define the underlying cause of impaired consciousness and in some cases to determine the severity of associated brain injury. There is often little history available to guide the clinician or radiologist, particularly in patients referred from the casualty department. In this review, we present the typical CT appearances of adult patients presenting with loss of consciousness for CT examination. We focus on the most common abnormalities that are identified in everyday radiological practice, emphasize important diagnostic signs that may enable a confident diagnosis to be made and discuss when further imaging may be warranted.


Assuntos
Encéfalo/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Inconsciência/diagnóstico por imagem , Adulto , Infecções do Sistema Nervoso Central/diagnóstico por imagem , Hematoma/diagnóstico por imagem , Humanos , Hipóxia-Isquemia Encefálica/diagnóstico por imagem , Hemorragias Intracranianas/diagnóstico por imagem , Hipertensão Intracraniana/diagnóstico por imagem , Tromboembolia/diagnóstico por imagem , Inconsciência/complicações
7.
Clin Neuropathol ; 23(1): 8-15, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14986928

RESUMO

OBJECTIVE: Non-functioning pituitary adenomas (NFAs) are a distinct group of pituitary adenomas, which comprise approximately 20% of pituitary adenomas. Although most pituitary adenomas are benign, there is a subset of adenomas that behaves in an aggressive fashion, with either invasion of the surrounding structures or recurrence. The aim of this study was to investigate whether the behaviour of NFAs can be predicted using immunohistochemical markers that label proliferating and apoptotic cells, including a new marker for apoptosis (M30 CytoDEATH). This is the first study to analyse both the proliferation labelling index (LI) and the apoptotic index (AI) in NFAs and to correlate the labelling indices of these histological markers with tumor growth rate as measured by 2 postoperative MRI scans. MATERIAL AND METHODS: 40 patients in total were included in the study. 20 patients with high growth rate and percentage change in the pituitary adenoma volume as assessed on 2 postoperative MRI scans were age/sex matched to 20 patients with low growth rate or percentage change. RESULTS: There is no significant statistical difference of the histological and immunohistochemical indices assessed between cases and controls. CONCLUSION: The routine assessment of the proliferation and the apoptotic markers used in this study in NFAs has no prognostic value.


Assuntos
Adenoma/metabolismo , Adenoma/patologia , Apoptose/fisiologia , Biomarcadores Tumorais/metabolismo , Neoplasias Hipofisárias/metabolismo , Neoplasias Hipofisárias/patologia , Adulto , Idoso , Divisão Celular/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes
9.
Eur J Neurol ; 8(1): 37-42, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11509079

RESUMO

We investigated the relationship between local tissue destruction, diffuse cerebral atrophy and clinical progression in patients with established multiple sclerosis (MS). Twenty-nine patients with MS (13 patients with relapsing--remitting and 16 with secondary progressive disease) were included in a prospective serial study. Cerebral volumes, T1 hypointense lesion volumes, T2 hyperintense lesion volumes at baseline and at 18 months follow-up, and the volume of monthly enhancing lesions from month 0 to month 9 were assessed on magnetic resonance imaging (MRI) brain scans using highly reproducible semi-automated quantitative techniques. The main outcome measures were the MRI parameters and disability on Kurtzkes' Expanded Disability Status Scale. There was a significant correlation between the change (increase) in T1 lesion volume and progressive cerebral atrophy, whereas no correlation between the T2 lesion volume and atrophy was seen over the same follow-up period. The change in T1 lesion volume correlated more strongly than did T2 lesion volume change with the change in disability. We conclude that hypointense abnormalities detected in T1-weighted brain scans and cerebral atrophy may be directly linked. Although one should bear in mind some potential for reversibility due to inflammatory, oedematous lesions, these MR measures are a useful marker of progressive tissue damage and clinical progression in established MS.


Assuntos
Encéfalo/patologia , Imageamento por Ressonância Magnética , Esclerose Múltipla/complicações , Esclerose Múltipla/diagnóstico , Adulto , Atrofia , Avaliação da Deficiência , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/fisiopatologia , Estudos Prospectivos
10.
Mol Ecol ; 10(3): 627-38, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11298974

RESUMO

Long-term studies of hybrid zones can provide valuable insight into a number of questions that have long attracted the attention of evolutionists. These questions range from the stability and fate of hybrid zones to the relative fitness of hybrids. In this paper we report the results of a 14-year survey of the Allonemobius fasciatus-Allonemobius socius hybrid zone. Populations were collected intensively in 1986 and 1987 and then more sporadically through the end of the 1980s and throughout the 1990s. By documenting changes in the genetic composition of populations near and within the zone during this period of time we assessed: the strength of the reproductive isolation between the two species; the relative growth rates (which can be considered a surrogate of relative fitness) of genotype classes corresponding to hybrids and to pure species individuals; and, the power of single-year and multi-year measurements of relative growth rates to predict changes in the genetic composition of mixed populations through time. In brief, we found very large year-to-year variation in the relative growth rates of pure species and hybrid individuals. This variation may reflect the fact that both species are at the edge of their range and perhaps at the limits of their ability to deal with environmental perturbations. As a consequence of the variation, even multi-year estimates of relative growth rates often provided imprecise predictions regarding the future genotypic composition of mixed populations. Despite our limited ability to predict the dynamics of individual populations, some trends are apparent. A. socius, the southern species, has clearly increased in frequency along a transect through the Appalachian Mountains, indicating that the zone is moving north in this region. In contrast, the zone appeared to be more stable along the East Coast transect. Within mixed populations, character-index profiles are often bimodal and stable through time, indicating relatively strong reproductive isolation between the two species that is not being reinforced, nor is it breaking down.


Assuntos
Quimera/fisiologia , Variação Genética , Gryllidae/genética , Alelos , Animais , Evolução Biológica , Quimera/genética , Quimera/crescimento & desenvolvimento , Simulação por Computador , Eletroforese , Meio Ambiente , Feminino , Gryllidae/fisiologia , Vigor Híbrido/genética , Vigor Híbrido/fisiologia , Hibridização Genética/genética , Masculino , Dinâmica Populacional , Fatores de Tempo , Estados Unidos
11.
Am J Bot ; 87(9): 1217-27, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10991892

RESUMO

Long-distance seed dispersal influences many key aspects of the biology of plants, including spread of invasive species, metapopulation dynamics, and diversity and dynamics in plant communities. However, because long-distance seed dispersal is inherently hard to measure, there are few data sets that characterize the tails of seed dispersal curves. This paper is structured around two lines of argument. First, we argue that long-distance seed dispersal is of critical importance and, hence, that we must collect better data from the tails of seed dispersal curves. To make the case for the importance of long-distance seed dispersal, we review existing data and models of long-distance seed dispersal, focusing on situations in which seeds that travel long distances have a critical impact (colonization of islands, Holocene migrations, response to global change, metapopulation biology). Second, we argue that genetic methods provide a broadly applicable way to monitor long-distance seed dispersal; to place this argument in context, we review genetic estimates of plant migration rates. At present, several promising genetic approaches for estimating long-distance seed dispersal are under active development, including assignment methods, likelihood methods, genealogical methods, and genealogical/demographic methods. We close the paper by discussing important but as yet largely unexplored areas for future research.

12.
J Neurol ; 245(5): 273-5, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9617707

RESUMO

The aim of this study was to assess the variability of lesion load measurements for repeated brain magnetic resonance imaging (MRI) scans judged to have either poor or good repositioning quality on the basis of subjective criteria used for clinical trials in multiple sclerosis (MS). Scan-rescan variability was also compared with the intra-observer variability assessed from three repeated volume measurements of the same scan. Nine patients with MS were studied; each of them underwent the scan-rescan procedure on the same day. Five scans were considered to have poor and four scans to have good repositioning. Between these two groups there were no differences in either the mean lesion loads or the measurement variance. For the whole group of patients, the intra-observer variability of repeated measurements gave a significantly lower coefficient of variation (COV = 4.9%) than the variability owing to repositioning (COV = 8.9%, P < 0.01, F test). Our results confirm that the effect of repositioning on brain MRI lesion load assessment is stronger than that owing to the intra-observer variability for repeated measurements and indicate that the simple visual judgment about the scan repositioning quality seems unable to predict the scan-rescan reproducibility.


Assuntos
Encéfalo/patologia , Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico , Variações Dependentes do Observador , Garantia da Qualidade dos Cuidados de Saúde , Adulto , Análise de Variância , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
13.
J Neurol Neurosurg Psychiatry ; 64(2): 197-203, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9489530

RESUMO

OBJECTIVES: To assess whether multiple sclerosis lesion volume measurements derived using the fast fluid attenuated inversion recovery (fFLAIR) sequence show better reproducibility or correlation with disability than those derived using the conventional spin echo (CSE) sequence. METHODS: Part I: twenty five patients with multiple sclerosis were scanned with CSE, fast spin echo (FSE), and fFLAIR. Lesion volume was determined twice for each sequence using a local threshold segmentation technique. Part II: fifty six patients with multiple sclerosis were scanned with CSE and fFLAIR. Total and regional brain lesion volumes were compared with the Kurtzke extended disability scale (EDSS) and functional systems scores (FSS). RESULTS: Part I: analysis times were significantly longer for CSE than for FSE or fFLAIR. There was no significant difference in the reproducibility of the three sequences. Part II: total lesion volumes were similar but posterior fossa lesion volumes were significantly greater for CSE and subcortical lesion volumes significantly greater for fFLAIR. There was a significant correlation between total volume and EDSS with both sequences (CSE r=0.49; fFLAIR r=0.44). Correlations for the two sequences showed minor differences when anatomical region and FSS were considered separately. CONCLUSIONS: CSE, FSE, and fFLAIR are equally reproducible; FSE yields lower volumes than CSE; fFLAIR gives similar volumes to CSE but underscores the posterior fossa. Overall clinical correlations are similar for CSE and fFLAIR.


Assuntos
Encéfalo/patologia , Avaliação da Deficiência , Imageamento por Ressonância Magnética/instrumentação , Esclerose Múltipla/patologia , Adulto , Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Guias como Assunto , Humanos , Pessoa de Meia-Idade , Recidiva , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
14.
Neurology ; 50(1): 238-44, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9443486

RESUMO

In this study, we evaluated the intra- and interobserver variabilities in measuring lesion load of brain MRI abnormalities present on proton-density scans from patients with MS, using using both manual outlining or a semiautomated local thresholding technique (LTT). We also evaluated how these variabilities were affected by the use of standard rules for lesion load measurements, training, and different measurement strategies. The intraobserver variabilities obtained after establishing rules for lesion load measurements and training were not significantly different from those obtained before any consensus among the observers, both for manual outlining and for the LTT. On the contrary, the interobserver variabilities obtained with manual outlining or the LTT were significantly reduced when rules for lesion load measurements were used. For manual outlining, the intraobserver variability did not significantly change when the measurements were performed after an experienced radiologist identified lesions or when using adjacent slices and the corresponding T2-weighted images as reference for lesion identification. On the contrary, for the LTT, the intraobserver variability was significantly reduced by the use of the radiologic marking. The interobserver variabilities for both manual outlining and the LTT were reduced compared with the free condition when these measurement strategies were used. Our findings demonstrate that both lesion identification and outlining are important sources of variation for MRI lesion load measurements in MS and that there are simple strategies to reduce such variation that might be useful when planning clinical trials.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/estatística & dados numéricos , Imageamento por Ressonância Magnética/normas , Esclerose Múltipla/diagnóstico , Educação/normas , Educação/estatística & dados numéricos , Educação Médica Continuada/normas , Educação Médica Continuada/estatística & dados numéricos , Humanos , Variações Dependentes do Observador , Avaliação de Programas e Projetos de Saúde , Radiografia/normas , Radiografia/estatística & dados numéricos , Reprodutibilidade dos Testes
15.
Neurology ; 49(2): 364-70, 1997 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9270563

RESUMO

We performed fast fluid-attenuated inversion recovery (fFLAIR) and conventional spin echo (CSE) brain MRI in 32 multiple sclerosis (MS) patients (eight each benign, relapsing-remitting, primary progressive, and secondary progressive). We compared number and site of lesions detected on each sequence. With initial separate assessment, we identified a total of 3,668 lesions-2,892 by CSE and 2,943 by fFLAIR. Following simultaneous review of the sequences, we identified an additional 217 lesions on fFLAIR and 229 on CSE. fFLAIR detected fewer lesions in the posterior fossa (66 versus 138, p = 0.001), fewer small (< 5 mm) discrete cerebral white matter lesions (671 versus 829, p = 0.0002), more subcortical lesions (542 versus 306, p < 0.0001), and more large discrete lesions (419 versus 385, p = 0.0006). Its relatively poor detection of posterior fossa lesions makes it premature for fFLAIR to replace CSE as the primary sequence for detecting MS lesions in clinical trials.


Assuntos
Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico , Adulto , Idoso , Estudos de Coortes , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade
16.
Neurology ; 49(2): 371-7, 1997 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9270564

RESUMO

We evaluated the effect of interscanner variation on brain MRI-measured lesion volumes and measurement reproducibility in MS. Twenty clinically definite MS patients were each scanned on two or three scanners (a total of 14 scanners were used). In addition, a formalin-fixed MS brain was studied on eight scanners from different manufacturers and with different field strengths. For the formalin-fixed MS brain, on each machine we obtained two scans with slice thicknesses of 5 and 3 mm. Only 5-mm-thick slices were obtained from patients. The lesion volume present on each scan was evaluated three times by a single observer in random order, using a local thresholding technique. In two groups of eight patients scanned on machines with different field strengths, the mean lesion volumes present on scans obtained at 1.5 T were significantly higher than those measured on scans obtained with machines operating at 0.5 and 1.0 T (p < 0.01). When a single observer repeatedly evaluated the same scan, a median introbserver agreement of 98.7% (95% CI, 97.9 to 99.1) was achieved. However, when the observer evaluated the scans from different MRI scanners, the agreement (an interscanner agreement) fell to 91.1% (CI, 90.2 to 94.1). When only scanners operating at 1.5 T were considered, the median interscanner agreement was 96.7% (CI, 95 to 97.5). Also, for the formalin-fixed MS brain, the intraobserver agreements obtained with both slice thicknesses were significantly higher than the corresponding interscanner agreements. The interscanner agreement, but not the intraobserver agreement, obtained with a slice thickness of 3 mm was higher than that obtained with a slice thickness of 5 mm. Our results indicate that lesion volume measurements in MS are influenced significantly by the use of different MR scanners and that a patient included in a serial study should be always scanned with the same MR machine using 3-mm thick slices.


Assuntos
Encéfalo/patologia , Imageamento por Ressonância Magnética/instrumentação , Esclerose Múltipla/diagnóstico , Adulto , Artefatos , Ensaios Clínicos como Assunto , Feminino , Fixadores , Formaldeído , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes
17.
Neuroradiology ; 39(6): 441-5, 1997 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9225327

RESUMO

MRI readily detects the lesions of multiple sclerosis (MS) in the brain and spinal cord. Conventional MRI sequences do not, however, permit distinction between the various pathological characteristics (oedema, demyelination, axonal loss and gliosis) of lesions in MS. Magnetisation transfer (MT) imaging may be more specific in distinguishing the pathologies responsible for disability in MS, namely demyelination and axonal loss, and therefore may have a potential role in monitoring treatment. We have applied MT imaging to the cervical spinal cord to see if it is feasible to measure MT ratios (MTR) in this region where pathological changes may result in considerable disability. We studied 12 patients with MS and 12 age- and sex-matched normal controls using a sagittal T2-weighted fast spin-echo sequence with and without an MT pulse. The median value for cervical cord mean MTR measurement in normal controls was 19.30% units (interquartile range 19.05-19.55), whereas values were significantly lower in MS patients (median = 17.95% units, interquartile range 17.25-19.00, P = 0.0004). There was a low intrarater variability for repeated mean MTR measurements. We conclude that it is possible to measure MTR in the cervical spinal cord, that a significant reduction occurs in patients with MS, and that there may be a role for this measure in future MS treatment trials.


Assuntos
Imageamento por Ressonância Magnética , Esclerose Múltipla/diagnóstico , Medula Espinal/patologia , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Exame Neurológico
18.
Neuroradiology ; 39(4): 243-9, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9144670

RESUMO

Axial fast FLAIR images of the brains of 40 normal volunteers in four age groups between 16 and 55 years were examined and the number and size of areas of increased white-matter signal recorded. Increased signal in the corticospinal tract region was seen at the level of the internal capsule in all subjects, extending up towards the centrum semiovale and down towards the pons for 0.5-5.5 cm (median 2.5 cm). In all cases the IIIrd and IVth ventricles were outlined by a thin line of high signal. Focal areas of high signal (caps) were seen around the frontal and occipital horns in 90% and 77% respectively; 54% of caps were asymmetrical. None of the above features varied with the age or sex of the subject, but the numbers of discrete white matter 'lesions' increased with age. The findings are used to suggest guidelines for the identification of areas of 'normal' high signal to be excluded in quantification of lesions on fast FLAIR images.


Assuntos
Encefalopatias/diagnóstico , Encéfalo/patologia , Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Adolescente , Adulto , Artefatos , Encefalopatias/patologia , Tronco Encefálico/patologia , Córtex Cerebral/patologia , Ventrículos Cerebrais/patologia , Líquido Cefalorraquidiano , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico , Esclerose Múltipla/patologia , Tratos Piramidais/patologia , Valores de Referência , Sensibilidade e Especificidade , Tálamo/patologia
19.
Neuroradiology ; 39(3): 161-5, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9106285

RESUMO

Changes on serial assessments of brain MRI lesion load are used for monitoring therapeutic efficacy in patients with multiple sclerosis (MS). We assessed the accuracy and reliability of conventional spin-echo (CSE) and fast spin-echo (FSE) sequences for measurement of lesion volume using a semiautomated contour technique. Cranial CSE and FSE examinations of 18 patients with secondary progressive MS were studied. The mean lesion load was slightly higher with the CSE sequence (p = 0.002). Intraobserver variability was significantly higher for FSE than for CSE, according to both the coefficient of variation between two measurements (mean 2.48% and 1.35% respectively, p < 0.05) and back-transformed 95% limits of agreement (1.005-1.060 for FSE; 0.988-1.019 for CSE). Although FSE sequences are quicker and the total lesion volume measurements are similar to those obtained with CSE, the poorer reproducibility raises doubts about the use of FSE to replace CSE in clinical trials.


Assuntos
Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Esclerose Múltipla/diagnóstico , Encéfalo/patologia , Humanos , Interferon beta/administração & dosagem , Esclerose Múltipla/terapia , Variações Dependentes do Observador , Sensibilidade e Especificidade , Software , Resultado do Tratamento
20.
J Neurol ; 244(2): 119-24, 1997 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9120494

RESUMO

Recent reports have suggested that fluid attenuated inversion recovery (FLAIR) is a technique superior to conventional (CSE) or fast spin echo (FSE) T2-weighted sequences in detecting intrinsic lesions both in the brain and spinal cord. We report our experience of an inversion recovery prepared FSE, which we refer to as fast FLAIR, in a comparative study of ten patients with clinically definite multiple sclerosis (MS) who underwent cervical cord and brain imaging with both FSE and fast FLAIR. The results showed that in the cerebral hemispheres fast FLAIR detected more lesions than FSE (P < 0.001). However, FSE detected more lesions than fast FLAIR in the posterior fossa (P = 0.02) and in the cord fast FLAIR was much inferior detecting only 2 of 33 lesions seen on FSE. Estimating the T2 relaxation times of lesions in each of three areas (periventricular, posterior fossa, cervical cord) showed that the T2 value of posterior fossa and cervical cord lesions was significantly lower than that of periventricular lesions, suggesting that the lesion composition is different and consequently their imaging appearances are different. In conclusion, although fast FLAIR improves the detection of MS lesions in the cerebral hemispheres, its substantially lower sensitivity in the posterior fossa and spinal cord is a potentially important limitation to its use as a tool for the diagnosis of MS and for monitoring therapies. Further studies are needed to elucidate the mechanisms underlying the loss of sensitivity.


Assuntos
Encéfalo/patologia , Imagem Ecoplanar/métodos , Esclerose Múltipla/diagnóstico , Medula Espinal/patologia , Fossa Craniana Posterior/patologia , Humanos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...