Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orthop Traumatol ; 25(1): 34, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963583

RESUMO

BACKGROUND: Because lateral epicondylitis is a common musculoskeletal disorder that affects the forearm's extensor tendons, an effective therapeutic approach should reverse the degeneration and promote regeneration. This study aimed to compare the efficacies of autologous blood (AB) injection, corticosteroid (CS) injection, and a combined injection of both in treating lateral epicondylitis (LE), hypothesizing that the combined approach might offer immediate symptom resolution and a lower recurrence. MATERIALS AND METHODS: A total of 120 patients diagnosed with lateral epicondylitis were systematically distributed among three distinct therapeutic injection groups. Those in the AB group were administered 1 ml of autologous venous blood mixed with 2 ml of 2% prilocaine HCl. Participants in the CS category were given 1 ml of 40 mg methylprednisolone acetate mixed with 2 ml of 2% prilocaine HCl. Meanwhile, patients in the combined group received a mixture containing 1 ml each of autologous venous blood and 40 mg methylprednisolone acetate along with 1 ml of 2% prilocaine HCl. Prior to receiving their respective injections, a comprehensive assessment of all participants was carried out. Follow-up assessments were subsequently conducted on days 15, 30, and 90 utilizing metrics of the patient-rated tennis elbow evaluation (PRTEE) and measurements of hand grip strength (HGS). RESULTS: One patient dropped out from the combined group, and 119 patients completed the trial. No complications were recorded during the course of follow-up. By day 15, all groups had demonstrated significant PRTEE improvement, with CS showing the most pronounced reduction (p = 0.001). However, the benefits of CS had deteriorated by day 30 and had deteriorated further by day 90. The AB and AB + CS groups demonstrated sustained improvement, with AB + CS revealing the most effective treatment, achieving a clinically significant improvement in 97.4% of the patients. The improved HGS parallelled the functional enhancements, as it was more substantial in the AB and AB + CS groups (p = 0.001), corroborating the sustained benefits of these treatments. CONCLUSIONS: The study concluded that while AB and CS individually offer distinct benefits, a combined AB + CS approach optimizes therapeutic outcomes, providing swift and sustained functional improvement with a lower recurrence rate. These findings have substantial clinical implications, suggesting a balanced, multimodal treatment strategy for enhanced patient recovery in LE. LEVEL OF EVIDENCE: Randomized clinical trial, level 1 evidence. TRIAL REGISTRATION: NCT06236178.


Assuntos
Transfusão de Sangue Autóloga , Acetato de Metilprednisolona , Metilprednisolona , Prilocaína , Cotovelo de Tenista , Humanos , Cotovelo de Tenista/terapia , Cotovelo de Tenista/tratamento farmacológico , Masculino , Feminino , Transfusão de Sangue Autóloga/métodos , Pessoa de Meia-Idade , Adulto , Metilprednisolona/administração & dosagem , Resultado do Tratamento , Prilocaína/administração & dosagem , Acetato de Metilprednisolona/administração & dosagem , Anestésicos Locais/administração & dosagem , Glucocorticoides/administração & dosagem , Medição da Dor
2.
Int Orthop ; 48(8): 2201-2209, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38771534

RESUMO

PURPOSE: This retrospective study aimed to investigate the factors associated with the breakage of tibio-fibular syndesmotic screws (SS). METHODS: 69 patients with unstable AO-Weber Type 44-B ankle fractures who underwent three cortex SS (3.5 mm ø) fixation were included. Patients were followed for at least one year (mean, 18.3 ± 7.6 months). At the final follow-up, patients with broken (Group I) and intact (Group II) SS were compared regarding age, gender, height, weight, body mass index, fracture type, SS length, location, and orientation. Multivariate logistic regression was used to identify the independent risk factors associated with SS breakage. The sensitivity, specificity, cut-off value, and area under the ROC curve were analyzed. RESULTS: A stepwise backward logistic regression analysis revealed that age was the only independent predictor for SS breakage (OR = 0.938, 95% CI = 0.904-0.973, R2 = 0.270). ROC curve analysis demonstrated that patients younger than 36 years were associated with seven times increased risk of SS breakage [Odds ratio (95% CI), 7.042 (2.251-22.031)]. CONCLUSION: Age under 36 years was the only significant risk factor for SS breakage. The higher incidence of breakage of the syndesmotic screw can be informed to patients younger than 36.


Assuntos
Fraturas do Tornozelo , Parafusos Ósseos , Fixação Interna de Fraturas , Humanos , Feminino , Masculino , Estudos Retrospectivos , Fatores de Risco , Adulto , Pessoa de Meia-Idade , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/efeitos adversos , Fraturas do Tornozelo/cirurgia , Fíbula/cirurgia , Fíbula/lesões , Fatores Etários , Tíbia/cirurgia , Adulto Jovem , Idoso
3.
Eur J Orthop Surg Traumatol ; 34(2): 853-862, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37747556

RESUMO

PURPOSE: The purpose of this cadaver study was to examine the surface morphology of the osteochondral grafts harvested from the femoral condyles using the free-hand graft harvesting technique. MATERIALS AND METHODS: One hundred osteochondral grafts were harvested with 6.5 mm chisels at ten different donor sites using the free-hand technique in five paired knee specimens (Mean age: 56.4 years). The cartilage and subchondral bone surface angles were measured through multiplanar reconstruction computerized tomography examination. The cartilage thickness was measured with a MicroScribe G2X digitizer with an accuracy of 0.02 mm. An acceptable congruity could be obtained when these plugs were transferred to a perpendicular socket (articular step-off of less than 1 mm and 0.5 mm) was evaluated. RESULTS: Four plugs were damaged or broken during harvesting due to technical difficulties; thus remaining 96 plugs were analyzed. The cartilage thickness varied between 1.36 mm and 3.26 mm across the donor sites. The cartilage was the thinnest in the medial intercondylar notch and thickest in the lateral supracondylar notch. Twenty of ninety-six plugs (20.8%) had unacceptable cartilage surface inclination according to the > 0.5 mm protrusion criteria. Of these plugs, 14 were harvested from the lateral intercondylar notch, whereas five of 96 plugs (5.2%) had unacceptable cartilage surface inclination according to the > 1 mm protrusion criteria. Of these plugs, all were harvested from the lateral intercondylar notch. CONCLUSIONS: High rates of unacceptable plugs (up to 100%) might be harvested from the lateral intercondylar notch. In large chondral lesions that require multiple plugs, lateral and medial supracondylar ridges were the best donor sites for perpendicular plug harvesting, whereas lateral intercondylar notch should be avoided.


Assuntos
Cartilagem Articular , Humanos , Pessoa de Meia-Idade , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/cirurgia , Transplante Ósseo/métodos , Transplante Autólogo , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Articulação do Joelho/patologia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Fêmur/anatomia & histologia , Cadáver
4.
Chin J Traumatol ; 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-38065705

RESUMO

PURPOSE: The purpose of this cadaveric study was to compare the volume and weight of bone graft harvested using the curettage vs. the trephination technique from the anterior iliac crest. METHODS: Embalmed cadavers were studied in this experimental research. The right hemipelvis of each cadaver was used for the trephine bone harvesting technique, whereas the left hemipelvis was used for the conventional curettage technique. The weight and the volume of the harvested bone were measured and statistically compared between the 2 sides. The Wilcoxon Signed-Rank test was employed to compare the graft volume and weight obtained from the right and left sides of the hemipelvis. RESULTS: Ten embalmed adult cadavers were used in this study. All subjects were Caucasian males with a mean age of 59.8 years (range 44 - 73 years) at the time of death. A total of 81 cylindrical bone grafts were harvested from the right iliac crest. In 9 out of 81 (11.1 %), the cortex of the ilium was penetrated by the chisel. The mean weight of the bone graft harvested with the trephine technique (26.97 ± 2.32) g was heavier than the curettage technique (23.74 ± 2.09) g (p = 0.007). Similarly, the volume of the bone graft was higher in the trephine technique (8.40 ± 0.84) cm3 compared to the curettage technique (6.60 ± 1.26) cm3 (p = 0.011). The trephination technique lasted a mean of (12.76 ± 1.87) min (range 10.30-16.10 min), while the curettage technique lasted a mean of (14.53 ± 0.89) min (range 13.50-16.00 min) (p = 0.028). CONCLUSION: Harvesting anterior iliac crest bone graft with the trephine technique provides a higher bone volume and weight than the conventional curettage technique. The trephine technique might be advocated over the curettage technique, especially when a large amount of autologous bone graft is required. However, a meticulous harvesting technique should be followed to prevent complications, particularly the three-dimensional anatomy should be kept in mind, and the depth of trephination should be well-controlled. CLINICAL TRIAL REGISTRATION: Institutional Review Board registration: 2022/499.

5.
J Foot Ankle Res ; 16(1): 70, 2023 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-37840128

RESUMO

BACKGROUND: This prospective study aimed to test the reliability and validity of hallux valgus angle (HVA) measurement on smartphone digital photographs compared with the standard radiographic evaluation. METHODS: Twenty Seven female patients (45 feet) with forefoot deformity were evaluated with weight-bearing anteroposterior foot radiographs and smartphone photographs. Radiographic hallux valgus angle (rHVA) was measured on digital radiographs. Two different photographic HVA measurement methods were used. In the first, the longitudinal axes of the first metatarsal and proximal phalanx were determined, and the angle between these axes was measured (pHVA), similar to the radiographic method. In the other method, the angle of the margo medialis pedis was measured on the photograph (pMMP). Two independent observers performed all measurements twice on two different occasions. Reliability analysis was performed using the interclass correlation coefficient. Agreement between the measurements was tested using Bland-Altman analysis. RESULTS: The repeated rHVA, pHVA and pMMP measurements showed excellent intra and inter-observer reliability, with ICC values above 0.900. The mean rHVA, pHVA, and pMMP were statistically similar (p:0.929, 27.03°±8.7°, 27.11°±8.8° and 26.5°±9.0° respectively). The mean difference between the rHVA and pHVA was - 0.07°±5.1° (range, --9.67 to 9.56°), and the mean difference between the rHVA and pMMP was 0.53°±4.4° (range, -9.76° to 8.22°). There was a strong positive correlation between both photographic methods and radiographic measurements (rho = 0.809, p = 0.001 and rho = 0.872, p = 0.001). In the Bland Altman plot, the upper and lower LOAs (95%CI) ranged from - 10.11° to 9.93° for rHVA and pHVA, and from - 8.26° to 9.33° for rHVA and pMMP. Linear regression analysis showed a proportional bias for pHVA but not for the pMMP (p:0.010 versus p:0.633, respectively). The range of the mean difference (prediction interval) between the pMMP and rHVA was 17.59° and 20° for pHVA and rHVA. Simple linear regression showed that the rHVA was predicted by the following equation: rHVA = 4.73 + 0.84 × pMMP (r2 = 0.761, p < 0.001). CONCLUSIONS: Although measuring HVA through smartphone photographs is reliable, it is not a valid prediction method. LEVEL OF EVIDENCE: Level II, diagnostic assessment.


Assuntos
Hallux Valgus , Ossos do Metatarso , Humanos , Feminino , Hallux Valgus/diagnóstico por imagem , Smartphone , Reprodutibilidade dos Testes , Estudos Prospectivos ,
6.
Arch Orthop Trauma Surg ; 143(11): 6675-6684, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37453933

RESUMO

OBJECTIVE: Peroneus longus tendon (PLT) has become a reliable autologous graft option for various ligament reconstructions. But there are potential risks and complications associated with its use as a graft. This retrospective study aimed to examine the complications and donor site morbidity following PLT harvesting. PATIENTS AND METHODS: A retrospective review was performed on an institutional digital patient database, and all patients who underwent ligament reconstruction using PLT autograft were identified. Intraoperative, early, and late complications were reviewed using digital patient notes and patients underwent a complete physical examination during their final follow-up. Ankle function was assessed using the AOFAS score, and manual ankle muscle testing was performed on both sides. Sural nerve iatrogenic injury was evaluated with a dermatomal light touch examination. Cosmetic satisfaction due to incision scar and footwear complaints were also assessed. RESULTS: 82 patients (74 male, eight female) with a mean age of 31.9 ± 10.4 years (range, 16-66) were included in the final analysis. The mean follow-up time was 46.6 ± 30.3 months (range, 6-109). The mean AOFAS score for the donor side was 98.7 ± 3.3 (range, 87-100), and the contralateral side score was 100, with manual muscle testing graded as 5 in all movements and similar to the contralateral side. Fifteen patients (18.3%) had hypoesthesia over the dorsolateral aspect of the foot distal to the incision scar, two patients (2.4%) had hyperalgesia over the distal incision scar, and one patient (1.2%) had mild ankle instability. There were two cases (2.4%) of compartment syndrome, both of which were treated with fasciotomy and had complete regression of symptoms after 5 days. One patient (1.2%) had a transient peroneal nerve injury and foot drop that resolved in the sixth month. CONCLUSIONS: The results of this retrospective study suggest that harvesting the PLT is associated with a high rate of complications and donor site morbidity. The most common complication was hypoesthesia around the lateral side of the foot, although the ankle functions were not affected significantly. Two cases of compartment syndrome and one transient peroneal nerve injury were observed. Care should be taken while harvesting PLT autograft, and it should be kept in mind that peroneal nerve injury might occur. LEVEL OF EVIDENCE: Level IV, retrospective case series.


Assuntos
Cicatriz , Síndromes Compartimentais , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Estudos Retrospectivos , Hipestesia , Tendões/transplante
7.
J Orthop Traumatol ; 24(1): 30, 2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37358664

RESUMO

BACKGROUND: Conventionally, two 4.5 mm cortical screws inserted toward the posterior tibial cortex are usually advocated for the fixation of Fulkerson osteotomy. This finite element analysis aimed to compare the biomechanical behavior of four different screw configurations to fix the Fulkerson osteotomy. MATERIALS AND METHODS: Fulkerson osteotomy was modeled using computerized tomography (CT) data of a patient with patellofemoral instability and fixed with four different screw configurations using two 4.5 mm cortical screws in the axial plane. The configurations were as follows: (1) two screws perpendicular to the osteotomy plane, (2) two screws perpendicular to the posterior cortex of the tibia, (3) the upper screw perpendicular to the osteotomy plane, but the lower screw is perpendicular to the posterior cortex of the tibia, and (4) the reverse position of the screw configuration in the third scenario. Gap formation, sliding, displacement, frictional stress, and deformation of the components were calculated and reported. RESULTS: The osteotomy fragment moved superiorly after loading the models with 1654 N patellar tendon traction force. Since the proximal cut is sloped (bevel-cut osteotomy), the osteotomy fragment slid and rested on the upper tibial surface. Afterward, the upper surface of the osteotomy fragment acted as a fulcrum, and the distal part of the fragment began to separate from the tibia while the screws resisted the displacement. The resultant total displacement was 0.319 mm, 0.307 mm, 0.333 mm, and 0.245 mm from the first scenario to the fourth scenario, respectively. The minimum displacement was detected in the fourth scenario (upper screw perpendicular to the osteotomy plane and lower screw perpendicular to the posterior tibial cortex). Maximum frictional stress and maximum pressure between components on both surfaces were highest in the first scenario (both screws perpendicular to the osteotomy plane). CONCLUSIONS: A divergent screw configuration in which the upper screw is inserted perpendicular to the osteotomy plane and the lower screw is inserted perpendicular to the posterior tibial cortex might be a better option for the fixation of Fulkerson osteotomy. Level of evidence Level V, mechanism-based reasoning.


Assuntos
Parafusos Ósseos , Tíbia , Humanos , Fenômenos Biomecânicos , Análise de Elementos Finitos , Tíbia/cirurgia , Osteotomia/métodos , Fixação Interna de Fraturas/métodos
8.
Indian J Orthop ; 57(6): 838-846, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37214361

RESUMO

Purpose: This study aimed to investigate whether the Akagi line is a reliable anatomic landmark for adjusting the rotational axis of the tibial component in patients with patellofemoral (PF) malalignment. Materials and methods: This retrospective case-control study included 86 patients with PF instability and 129 controls. On the superimposed axial CT images, TT-TG, TT-PCL, nTT-TG, nTT-PCL, knee joint rotation, and the angle between the Akagi line and surgical transepicondylar axis (Akagi/sTEA angle) were measured. In addition, a modified Akagi line, drawn 1 cm medial to the patellar tendon attachment, was defined, and the angle between the new Akagi line and sTEA (mAkagi/sTEA angle) was also measured and compared between groups. Results: There were 86 patients (47 females, 39 males) in the case group and 129 patients (56 females, 73 males) in the control group with a mean age of 35.7 ± 17.9 years and 41.1 ± 18.8 years, respectively (p < 0.001). Radiologic variables of PF alignment (TT-TG, TT-PCL, nTT-TG, nTT-PCL, and knee joint rotation) were significantly abnormal in the case group (p < 0.001 for all variables). The Akagi/sTEA angle was significantly higher in the case group, resulting in 89.5% external malrotation of the tibial component (> 10°). However, the tibial component was 96.5% aligned correctly (between 10° external and 3° internal rotation) in the control group. Using the modified Akagi line significantly improved the rotational alignment, and normal tibial rotation increased to 93.3% of the case group. The Akagi/sTEA angle strongly correlated with the knee rotation (rho: 0.735, p: 0.001), TT-TG (rho: 0.715, p: 0.001) and nTT-TG (rho: 0.783, p: 0.001). But the TT-PCL (rho: 0.459, p: 0.001) and nTT-PCL (rho: 0.589, p: 0.001) had a medium correlation. Conclusions: The Akagi line might cause unacceptable external rotation of the tibial component in patients with PF malalignment. The use of the modified Akagi line described in this study may be a solution for the rotational mismatch between femoral and tibial components in TKA. Level of evidence: Level III, retrospective case-control study.

9.
Arch Orthop Trauma Surg ; 143(6): 3309-3317, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36018367

RESUMO

PURPOSE: The purpose of this randomized controlled study was to examine the effect of sealing the intramedullary canal with a bone or cement plug or leaving it empty on postoperative bleeding and pain MATERIALS AND METHODS: A total of 120 patients with knee osteoarthritis who underwent unilateral TKA participated in the trial and were assigned to one of three groups. The femoral canal was sealed with an autogenous bone plug (Group I) or cement plug (Group II), or it was left open (Group III). Estimated blood loss, Hemoglobin decline, bleeding into the drain, and postoperative pain w compared between groups. RESULTS: Six patients were excluded due to various reasons, and the remaining 114 patients were included in the final analysis. There were no significant variations in baseline clinical characteristics between the three groups (p > 0.05). Hemoglobin reduction between preoperative and 72 h after the surgery (p: 0.034) and estimated blood loss (p: 0.003) were significantly different between groups. The cement plug group showed the least bleeding. Although there was a significant difference between the cement and empty canal groups (p: 0.03 and p: 0.002, respectively), the difference between the cement and bone groups was similar regarding both hemoglobin reduction and estimated blood loss. The blood volume in the suction drain (p: 0.598) and transfusion rate (p: 0.087) were similar between the groups. VAS at the 12 h after the surgery was similarly high in each group (p: 0.676). It declined at 36 h after surgery, but no significant difference was determined between groups (p: 0.815). CONCLUSIONS: This study showed that estimated blood loss and hemoglobin reduction were significantly lower in the cement plug group than in the empty canal group. But bone plug group did not show any difference with both empty canal and cement plug groups. Sealing the IM canal or leaving it open did not change the bleeding into the drain, transfusion rate, and postoperative pain between groups. Based on these findings, sealing the IM canal with a cement plug might be recommended to diminish bleeding during TKA despite similar transfusion rates. LEVEL OF EVIDENCE: Level I, randomized controlled trial.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Hemorragia Pós-Operatória/prevenção & controle , Osteoartrite do Joelho/cirurgia , Dor Pós-Operatória/cirurgia , Hemoglobinas
10.
Knee ; 37: 132-142, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35779431

RESUMO

BACKGROUND: Antero-medialisation osteotomy combined with a distalisation procedure may require a more stable fixation as the osteotomy fragment loses both proximal and distal support. This finite element analysis aimed to compare the mechanical behaviour of different fixation techniques in tibial tubercle antero-medialisation osteotomy combined with distalisation procedure. METHODS: Tibial tubercle osteotomy combined with distalisation was modelled based on computerised tomography data, which were acquired from a patient with patellar instability requiring this procedure. Six different fixation configurations with two 3.5-mm cortical screws (1), two 4.5-mm cortical screws (2), three 3.5-mm cortical screws (3), three 4.5-mm cortical screws (4), three 3.5-mm screws with 1/3 tubular plate (5), and four 3.5-mm screws with 1/3 tubular plate (6) were created. A total of 1654 N of force was applied to the patellar tendon footprint on the tibial tubercle. Sliding, gap formation, and total deformation between the osteotomy components were analyzed. RESULTS: Maximum sliding (0.660 mm), gap formation (0.661 mm), and displacement (1.267 mm) were seen with two 3.5-mm screw fixation, followed by two 4.5-mm screws, three 3.5-mm screws, and three 4.5-mm screws, respectively, in the screw-only group. Overall, the minimum displacement was observed with the four 3.5-mm screws with 1/3 tubular plate fixation model. CONCLUSIONS: Plate fixation might be recommended for tibial tubercle antero-medialisation osteotomy combined with distalisation procedure because it might allow early active range of motion exercises and weight-bearing.


Assuntos
Instabilidade Articular , Articulação Patelofemoral , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Análise de Elementos Finitos , Humanos , Osteotomia/métodos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
11.
Asian Spine J ; 8(5): 571-80, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25346809

RESUMO

STUDY DESIGN: Eighty-four patients who had been treated for degenerative spinal diseases between January 2006 and June 2009 were reviewed retrospectively. PURPOSE: We aimed to compare the clinical and radiologic findings of manual workers who underwent posterolateral fusion (PLF) or posterior interbody fusion (PLIF) involving fusion of 3 or more levels of the spine. OVERVIEW OF LITERATURE: Previous studies have concluded that there is no significant difference between the clinical outcome of PLF and PLIF techniques. METHODS: After standard decompression, 42 patients underwent PLF and the other 42 patients underwent PLIF. Radiologic findings, Oswestry disability index (ODI) scores, and visual analogue scale (VAS) scores were assessed preoperatively and at 6-month intervals postoperatively and return to work times/rates were assessed for 48 months. RESULTS: Patients who underwent PLF had significantly shorter surgical time and less blood loss. According to the 48-month clinical results, ODI and VAS scores were reduced significantly in the two groups, but the PLIF group showed better results than the PLF group at the last follow-up. Return to work rate was 63% in the PLF group and 87% in the PLIF group. Union rates were found to be 81% and 89%, respectively, after 24 months (p=0.154). CONCLUSIONS: PLIF is a preferable technique with respect to stability and correction, but the result does not depend on only the fusion rates. Discectomy and fusion mass localization should be considered for achieving clinical success with the fusion technique. Before performing PLIF, the association of the long operative time and high blood loss with mortality and morbidity should be taken into consideration, particularly in the elderly and disabled patients.

12.
Acta Orthop Belg ; 76(4): 559-63, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20973368

RESUMO

We report a case of neglected bilateral femoral neck fracture related with transient osteoporosis in pregnancy (TOP) and primary hyperparathyroidism, in a 33-year-old female who presented with a fracture of both femoral necks without any history of trauma 20 days after delivery. Her pain was at first accepted as common musculoskeletal discomfort following labour, and the final diagnosis was made only 25 days after fracture. She was treated with primary internal fixation with cannulated lag screws and received medical treatment for hyperparathyroidism and TOP. She was followed up for 29 months following the operation. No complications, and more specifically no avascular necrosis (AVN) were noted during this time interval. The patient made a complete functional recovery. We would like to emphasize that major medical problems may be underdiagnosed during the last pregnancy trimester and postpartum period. Delay in the diagnosis and treatment of a femoral neck fracture is an important but not a decisive factor for the development of AVN.


Assuntos
Doenças Ósseas Metabólicas/complicações , Fraturas do Colo Femoral/etiologia , Fraturas Espontâneas/etiologia , Hiperparatireoidismo Primário/complicações , Complicações na Gravidez , Transtornos Puerperais/diagnóstico , Adulto , Feminino , Fraturas do Colo Femoral/diagnóstico , Fraturas Espontâneas/diagnóstico , Humanos , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...