Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 124(16): 161802, 2020 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-32383902

RESUMO

Electron antineutrino appearance is measured by the T2K experiment in an accelerator-produced antineutrino beam, using additional neutrino beam operation to constrain parameters of the Pontecorvo-Maki-Nakagawa-Sakata (PMNS) mixing matrix. T2K observes 15 candidate electron antineutrino events with a background expectation of 9.3 events. Including information from the kinematic distribution of observed events, the hypothesis of no electron antineutrino appearance is disfavored with a significance of 2.40σ and no discrepancy between data and PMNS predictions is found. A complementary analysis that introduces an additional free parameter which allows non-PMNS values of electron neutrino and antineutrino appearance also finds no discrepancy between data and PMNS predictions.

2.
Phys Rev Lett ; 121(17): 171802, 2018 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-30411920

RESUMO

The T2K experiment measures muon neutrino disappearance and electron neutrino appearance in accelerator-produced neutrino and antineutrino beams. With an exposure of 14.7(7.6)×10^{20} protons on target in the neutrino (antineutrino) mode, 89 ν_{e} candidates and seven anti-ν_{e} candidates are observed, while 67.5 and 9.0 are expected for δ_{CP}=0 and normal mass ordering. The obtained 2σ confidence interval for the CP-violating phase, δ_{CP}, does not include the CP-conserving cases (δ_{CP}=0, π). The best-fit values of other parameters are sin^{2}θ_{23}=0.526_{-0.036}^{+0.032} and Δm_{32}^{2}=2.463_{-0.070}^{+0.071}×10^{-3} eV^{2}/c^{4}.

3.
Dimens Crit Care Nurs ; 13(6): 292-300, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7729318

RESUMO

The Closed Tracheal Suction System (CTSS) is a multiple-use suction catheter available for suctioning the ventilator dependent patient. While research has been reported on its impact on oxygen desaturation, ventilator function, and nosocomial pneumonia, the practical issues of the technical design of the catheter and its advantage in decreasing exposure of staff to infected respiratory secretions have not been investigated. This study reports the critical care nurses' perceptions in the use of the SteriCath (Concord/Portex) CTSS focusing on hemodynamic stability, effectiveness of suctioning, patient safety and staff personnel exposure.


Assuntos
Cuidados Críticos , Intubação Intratraqueal/instrumentação , Sucção/instrumentação , Adulto , Idoso , Atitude do Pessoal de Saúde , Feminino , Humanos , Intubação Intratraqueal/enfermagem , Masculino , Pessoa de Meia-Idade , Recursos Humanos de Enfermagem Hospitalar/psicologia , Sucção/enfermagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...