J Diabetes Sci Technol ; 6(2): 294-301, 2012 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-22538138

RESUMO

OBJECTIVE: Glycemic control is a rapidly developing field in intensive care medicine with the aim of reducing mortality, morbidity, and cost. Current intensive care unit (ICU) glucose measurement technologies are susceptible to interference from medications, volume expanders, and other substances present in critically ill patients. We hypothesized that a fixed-wavelength mid-infrared (mid-IR) spectroscopy system would be accurate for measuring glucose levels of ICU patients. RESEARCH DESIGN AND METHODS: This is a prospective investigation of plasma samples from two different institutions treating a heterogeneous population of ICU patients. The first 292 samples were collected from 86 patients admitted to Stamford Hospital, and the next 352 samples were collected from 75 patients from three ICUs at the University of Maryland. Plasma samples were measured on a Fourier-transform infrared or a proprietary spectrometer, with a glucose prediction algorithm to correct for spectral interference, which were compared with reference measurements taken using a YSI 2300 glucose analyzer. RESULTS: Glucose values ranged from 24 to 343 mg/dl. Numerous medications and injury/disease states were observed in the patient populations, with metoprolol, fentanyl, and multiple organ failure the most prevalent. Despite these interferents, there was a high correlation (r ≥ 0.94) and low standard error (≤12.8 mg/dl) between the predicted glucose values and those of the YSI 2300 STAT Plus reference instrument in the three studies. A total of 95.1% of the 644 values in the three studies met International Organization for Standardization 15197 criteria. CONCLUSION: These results suggest that a fixed-wavelength mid-IR spectrometer can measure glucose accurately in the plasma of ICU patients.


Assuntos
Glicemia/metabolismo , Unidades de Terapia Intensiva , Monitorização Fisiológica/métodos , Espectroscopia de Infravermelho com Transformada de Fourier , APACHE , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Baltimore , Biomarcadores/sangue , Connecticut , Estado Terminal , Estudos de Viabilidade , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/normas , Valor Preditivo dos Testes , Estudos Prospectivos , Padrões de Referência , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Espectroscopia de Infravermelho com Transformada de Fourier/normas , Adulto Jovem
2.
J Diabetes Sci Technol ; 5(2): 345-52, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-21527104

RESUMO

OBJECTIVE: There are increasing calls for a precise, automated system to enable tight glycemic control and to avoid hypoglycemia in an intensive care unit setting. OptiScan Biomedical has developed a glucose monitor based on mid-infrared spectroscopy that withdraws blood samples (120 µl) and measures plasma glucose. The goal of this study was to validate the performance of the OptiScan Model 5000 over a wide range of glycemic levels in patients. RESEARCH DESIGN AND METHODS: Sixty people with type 1 (n = 18) or type 2 (n = 42) diabetes who were otherwise healthy were connected to OptiScanners. Their blood glucose concentrations were kept in a euglycemic, hypoglycemic (<75 mg/dl), and hyperglycemic (>180 mg/dl) range by intravenous administrations of insulin and glucose. OptiScanner venous blood samples were automatically withdrawn every 15 minutes. Reference measurements were done using the YSI 2300 glucose analyzer. RESULTS: The aggregate data points (1155 paired readings) were within International Organization for Standardization standards, with 98.6% of the glucose values within ±20% above 75 mg/dl and ±15 mg/dl below this value. A Clarke error grid analysis showed a total of 1139 points (98.6%) in zone A. Points outside of A exceeded the A zone boundary by an average of 4.3%. The r(2) was 0.99. The total coefficient for variance was 6.4%. CONCLUSIONS: These results show that the OptiScanner is highly accurate in healthy patients with diabetes across a wide range of glucose values. Mid-infrared spectroscopy may become the method of choice for highly accurate, high frequency, automated glucose measurements and may thus enable better glycemic control in critically ill patients.


Assuntos
Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 2/sangue , Espectrofotometria Infravermelho/métodos , Adolescente , Adulto , Idoso , Automação , Glicemia/metabolismo , Desenho de Equipamento , Feminino , Humanos , Hiperglicemia/diagnóstico , Hipoglicemia/diagnóstico , Masculino , Pessoa de Meia-Idade , Projetos de Pesquisa