Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diabetes Res Clin Pract ; 199: 110627, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36940793

RESUMO

AIMS: To evaluate the efficacy of an advance closed-loop (AHCL) system in restoring awareness of hypoglycemia in patients with type 1 diabetes (T1D). METHODS: We conducted a prospective study including 46 subjects with T1D flash glucose monitoring (FGM) or continuous glucose monitoring (CGM) switching to a Minimed 780G® system. Patients were classified in three groups according to the therapy used before switching to Minimed® 780G: multiple dose insulin (MDI) therapy + FGM (n = 6), continuous subcutaneous insulin infusion + FGM (n = 21), and sensor-augmented pump with predictive low-glucose suspend (n = 19). FGM/CGM data were analyzed at baseline, after 2 and 6 months on AHCL. Clarke's score of hypoglycemia awareness was compared at baseline and 6 months recordings. We also compared the efficacy of the AHCL system in improving A1c among patients with appropriate perception of symptoms of hypoglycemia compared to those presenting with impaired awareness of hypoglycemia (IAH). RESULTS: Participants had a mean age of 37 ± 15 and a diabetes duration of 20 ± 10 years. At baseline, 12 patients (27%) showed IAH as defined by a Clarke's score ≥ 3. Patients with IAH were older and had lower estimated glomerular filtration rate (eGFR) compared with those who did not have IAH; with no differences in baseline CGM metrics or A1c. An overall decrease in A1c was observed after 6 months on AHCL system (from 6.9 ± 0.5% to 6.7 ± 0.6%, P < 0.001), regardless of prior insulin therapy. The improvement in metabolic control was greater in patients with IAH, showing a reduction in A1c from 6.9 ± 0.5 to 6.4 ± 0.4% vs 6.9 ± 0.5 to 6.8 ± 0.6% (P = 0.003), showing a parallel increase in total daily boluses of insulin and automatic bolus correction administered by the AHCL system. In patients with IAH Clarke's score decreased from 3.6 ± 0.8 at baseline to 1.9 ± 1.6 after 6 months (P < 0.001). After 6 months on AHCL system, only 3 patients (7%) presented with a Clarke's score ≥ 3, resulting in an absolute risk reduction of 20% (95% confidence interval: 7-32) of having IAH. CONCLUSIONS: Switching from any type of insulin administration to AHCL system improves restoration of hypoglycemia awareness and metabolic control in patients with T1D, particularly in adults with impaired perception of hypoglycemia symptoms. TRIAL REGISTRATION: ClinicalTrial.gov ID NCT04900636.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Adulto , Adulto Jovem , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/efeitos adversos , Automonitorização da Glicemia , Glicemia/metabolismo , Estudos Prospectivos , Hipoglicemia/tratamento farmacológico , Insulina/efeitos adversos , Insulina Regular Humana/uso terapêutico , Sistemas de Infusão de Insulina , Percepção
2.
ACS Nano ; 12(6): 5932-5939, 2018 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-29812903

RESUMO

The unidirectional motion of information carriers such as domain walls in magnetic nanostrips is a key feature for many future spintronic applications based on shift registers. This magnetic ratchet effect has so far been achieved in a limited number of complex nanomagnetic structures, for example, by lithographically engineered pinning sites. Here we report on a simple remagnetization ratchet originated in the asymmetric potential from the designed increasing lengths of magnetostatically coupled ferromagnetic segments in FeCo/Cu cylindrical nanowires. The magnetization reversal in neighboring segments propagates sequentially in steps starting from the shorter segments, irrespective of the applied field direction. This natural and efficient ratchet offers alternatives for the design of three-dimensional advanced storage and logic devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...