Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Perfusion ; 18(5): 269-76, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14604242

RESUMO

There is limited published data on the agreement between techniques for monitoring heparin levels. The aim of this study was to validate the Hepcon/HMS, with particular focus on the agreement with laboratory anti-Xa assay. The performances of two ACT instruments--Hemochron and HemoTec--were also evaluated, including an assessment for interchangeability. Blood samples from 42 adult cardiopulmonary bypass (CPB) patients were analysed for activated clotting time (ACT), whole-blood heparin concentration (Hepcon/HMS) and anti-factor Xa (anti-Xa) plasma heparin concentration. Agreement between measures was determined using the method of Bland and Altman. Simple analysis of agreement between the Hepcon and anti-Xa heparin revealed the Hepcon has a mean bias of -0.46 U/mL, with the limits of agreement +/- 1.12 U/mL. The comparison between ACT instruments indicated a mean difference of -96 seconds for the HemoTec, with limits of +/- 265 seconds. The Hepcon/ HMS instrument displayed satisfactory agreement with anti-Xa plasma heparin concentration, as the expected variation would not be expected to cause problems in the clinical setting. Agreement between the two measurements of ACT may be satisfactory, provided each is assigned a different target value.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Monitoramento de Medicamentos/métodos , Heparina/sangue , Idoso , Testes de Coagulação Sanguínea/instrumentação , Testes de Coagulação Sanguínea/normas , Ponte de Artéria Coronária , Monitoramento de Medicamentos/normas , Procedimentos Cirúrgicos Eletivos , Inibidores do Fator Xa , Heparina/farmacocinética , Humanos , Pessoa de Meia-Idade , Farmacocinética , Tempo de Coagulação do Sangue Total/instrumentação , Tempo de Coagulação do Sangue Total/normas
2.
Perfusion ; 18(5): 277-81, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14604243

RESUMO

Activated clotting time (ACT) values were converted to heparin concentration, enabling an assessment of the accuracy of the ACT and a quantification of the prolongation imposed by bypass. Blood samples were obtained from 42 adult cardiopulmonary bypass (CPB) patients before and during bypass surgery. Samples were analysed for ACT (HemoTec ACT) and anti-factor Xa (anti-Xa) plasma heparin concentration. The mean heparin concentration calculated before bypass was an accurate reflection of plasma heparin; however, calculated values rose to around 170% of anti-Xa values upon connection to bypass. By adjusting for this rise, for 95% of cases the calculated heparin concentration would vary between 0.60 and 1.65 times anti-Xa values. Without accounting for artificial prolongation or individual sensitivities, the ACT may give values between 0.8 and 3.0 times that indicated by the anti-Xa assay. When both individual heparin sensitivities and the effects of bypass are considered, the ACT may provide a more suitable indication of heparin levels; however, typical use may overestimate heparin up to threefold.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Monitoramento de Medicamentos/normas , Heparina/sangue , Idoso , Testes de Coagulação Sanguínea/normas , Ponte de Artéria Coronária , Monitoramento de Medicamentos/métodos , Procedimentos Cirúrgicos Eletivos , Inibidores do Fator Xa , Heparina/farmacocinética , Humanos , Pessoa de Meia-Idade , Modelos Teóricos , Farmacocinética , Tempo de Coagulação do Sangue Total/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...