Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Aesthet Surg J ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38513359

RESUMO

BACKGROUND: Neuromodulator treatments of the perioral region are increasingly popular and aim to modulate the position of the modiolus. The predominantly targeted muscle is the depressor anguli oris (DAO) which allows for the modiolus to reposition cranially once temporarily relaxed. OBJECTIVES: To identify the precise anatomic position of the DAO in relation to the Marionette Line for increasing precision and reducing adverse events during neuromodulator treatments. METHODS: A total of n = 80 DAO muscles were investigated in n = 40 healthy, toxin naïve volunteers (11 males, 29 females) having a mean age of 48.15 (15) years and a mean body mass index of 24.07 (3.7) kg/m2. The location of the DAO in relation to the labiomandibular sulcus (LMS), its depth, extent, and thickness were investigated with high frequency ultrasound imaging. RESULTS: The skin surface projection of the LMS separates the DAO into medial and lateral portions. The distance between skin surface and muscle surface was on average 4.4 mm with males having a greater distance (p < 0.001) and higher BMI being an important influencing factor for a greater distance (p < 0.001). The thickness of the DAO was on average 3.5 mm with a range of 2.8-4.8 mm and with females having thinner muscles when compared to men (p < 0.001). The most favorable injection depth was calculated to be 6.1 mm for intra-muscular product placement. CONCLUSIONS: Understanding the perioral anatomy and the influence of age, sex, and BMI will potentially allow the injectors to increase efficacy and duration of neuromodulator treatments while expertly managing adverse events.

2.
Aesthet Surg J ; 44(3): 233-239, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-37418617

RESUMO

BACKGROUND: Addressing neck contouring with surgical and nonsurgical aesthetic procedures includes understanding the origin of platysmal banding. A theory was postulated to explain this phenomenon by isometric vs isotonic muscular contraction patterns. However, no scientific proof had been provided to date for its correctness. OBJECTIVES: The aim of this study was to confirm the correctness of the platysmal banding theory based on isometric vs isotonic muscular contractions. METHODS: Eighty platysma muscles from 40 volunteers (15 males and 25 females) were investigated (mean age 41.8; SD 15.2 years; mean BMI of 22.2; SD 2.3 kg/m2). Real-time ultrasound imaging was utilized to measure the increase in local muscle thickness inside and outside of a platysmal band as well as platysma mobility. RESULTS: Within a platysmal band, the local thickness of the muscle increases during muscular contractions by 0.33 mm (37.9%; P < .001). Outside of a platysmal band the thickness of the platysma muscle decreased by 0.13 mm (20.3%; P < .001). It was identified that within a platysmal band no gliding was detectable, whereas outside of a band an average muscle gliding of 2.76 mm was observed. CONCLUSIONS: The results confirm the correctness of the isometric vs isotonic platysma muscle contraction pattern theory: isotonic muscle contraction (gliding without increase in tension and therefore in muscle thickness) vs isometric muscle contraction (no gliding but increase in tension and therefore in muscle thickness). These 2 types of contraction patterns occur within the platysma simultaneously and are an indicator for zones of adhesion in the neck to guide surgical and nonsurgical aesthetic procedures.


Assuntos
Sistema Musculoaponeurótico Superficial , Masculino , Feminino , Humanos , Adulto , Contração Muscular/fisiologia , Pescoço/diagnóstico por imagem , Pescoço/cirurgia , Ultrassonografia
3.
Aesthet Surg J ; 43(3): 353-361, 2023 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36281772

RESUMO

BACKGROUND: Uncontrolled product spread is an important issue to consider in facial filler injections. Lack of precision can result in reduced effectiveness and surface projection, as well as irregularities and product visibility. OBJECTIVES: The authors sought to assess the precision of soft-tissue filler injections in the face by employing a cannula. METHODS: This single-center observational study investigated soft-tissue filler distribution utilizing real-time non-invasive ultrasound imaging. Outcome parameters included (1) the tissue plane of product distribution, (2) the extent of horizontal as well as vertical product spread at the injection site, and (3) the product surface area taking into account the multifactorial influence of several independent variables. Participants were followed up to 30 days post-injection. RESULTS: A total 100 facial injections were performed in 8 patients (2 males, 6 females) with a mean age of 37.20 (±6.34) years and a mean BMI of 22.21 (±1.39) kg/m.2. The plane of product distribution remained constant in approximately 90% of cases at day 0 (d0), d14, and d30. Mean horizontal product spread was higher compared with vertical spread, and both significantly decreased over all time points (P < .001). Mean product surface area was 22.51 ± 16.34 mm2 at d0, 15.97 ± 11.28 mm2 at d14, and 12.9 ± 9.15 mm2 at d30. Analysis employing generalized linear models revealed that injection volume and injection depth significantly influenced product surface area. CONCLUSIONS: Injection of soft-tissue filler employing a cannula allows precise application of the product within the intended tissue plane. Precision can be improved by injecting less product into deeper tissue layers.


Assuntos
Técnicas Cosméticas , Preenchedores Dérmicos , Masculino , Feminino , Humanos , Adulto , Face , Injeções , Ultrassonografia
4.
Aesthet Surg J ; 42(5): 518-526, 2022 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-34610093

RESUMO

BACKGROUND: The tear trough is one of the most challenging facial regions for soft-tissue filler injections. A thorough understanding of the underlying facial, muscular, and vascular anatomy is crucial to perform safe and effective tear trough injectable treatments. OBJECTIVES: The authors sought to evaluate the location and function of the angular vein in the tear trough in 3 different facial expressions: repose, smiling, and max. orbicularis oculi contraction. METHODS: Twenty study participants with a mean age of 48.3 years and mean BMI of 24.5 kg/m2 were investigated via functional ultrasound imaging. The diameter of the angular vein and the velocity and direction of venous blood flow were analyzed in repose, smiling, and during max. orbicularis oculi contraction. RESULTS: The angular vein was identified in 100% of the cases to travel inside the orbicularis oculi muscle (intra-muscular course) within the tear trough, whereas the angular artery was not identified in this location. The distance between the angular vein and the inferior orbital rim was (lateral to medial): 4.6 mm, 4.5 mm, 3.9 mm, and 3.8 mm. The caudally directed blood flow was in repose 10.2 cm/s and was 7.3 cm/s at max. orbicularis oculi muscle contraction; however, no blood flow was detectable during smiling. CONCLUSIONS: The diameter and the venous blood flow of the angular vein varied between the 3 tested facial expressions. Based on these anatomical findings, the deep injection approach to the tear trough is recommended due to the intramuscular course of the angular vein.


Assuntos
Pálpebras , Músculos Faciais , Pálpebras/anatomia & histologia , Face/diagnóstico por imagem , Músculos Faciais/anatomia & histologia , Músculos Faciais/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Ruptura , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...