Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol Exp ; 7(1): 49, 2023 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-37691033

RESUMO

BACKGROUND: Accurate knowledge of vessel anatomy is essential in facial reconstructive surgery. The technological advances of ultrasound (US) equipment with the introduction of new high-resolution probes improved the evaluation of facial anatomical structures. Our study had these objectives: the primary objective was to identify new surgical landmarks for the facial vein and to verify their precision with US, the secondary objective was to evaluate the potential of high-resolution US examination in the study of both the facial artery and vein. METHODS: Two radiologists examined a prospective series of adult volunteers with a 22-8 MHz hockey-stick probe. Two predictive lines of the facial artery and vein with respective measurement points were defined. The distance between the facial vein and its predictive line (named mandibular-orbital line) was determined at each measurement point. The distance from the skin and the area of the two vessels were assessed at every established measurement point. RESULTS: Forty-one volunteers were examined. The median distance of the facial vein from its predictive line did not exceed 2 mm. The facial vein was visible at every measurement point in all volunteers on the right side, and in 40 volunteers on the left. The facial artery was visible at every measurement point in all volunteers on the right and in 37 volunteers on the left. CONCLUSIONS: The facial vein demonstrated a constant course concerning the mandibular-orbital line, which seems a promising clinical and imaging-based method for its identification. High-resolution US is valuable in studying the facial artery and vein. RELEVANCE STATEMENT: High-resolution US is valuable for examining facial vessels and can be a useful tool for pre-operative assessment, especially when combined with the mandibular-orbital line, a new promising imaging and clinical technique to identify the facial vein. KEY POINTS: • High-resolution US is valuable in studying the facial artery and vein. • The facial vein demonstrated a constant course concerning its predictive mandibular-orbital line. • The clinical application of the mandibular-orbital line could help reduce facial surgical and cosmetic procedure complications.


Assuntos
Cirurgia Plástica , Adulto , Humanos , Artérias , Ultrassonografia
2.
World Neurosurg ; 160: e267-e277, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34999266

RESUMO

BACKGROUND: In the management of cerebrospinal fluid (CSF) leak, the identification of the exact discharge spot is paramount. This process can represent a challenge for the radiologist and the surgeon. In the present study, we analyzed a series of patients affected by endonasal CSF leak who underwent endoscopic surgical reconstruction aided by the use of ITF. The purpose of this work is to assess the efficacy of intraoperative ITF in addition to computed tomography (CT) and magnetic resonance imaging for correct topographic localization of the CSF leak. METHODS: Eighty-three patients were enrolled in the study. The main outcome was the concordance between the supposed radiologic defect site and the actual one seen intraoperatively. Recurrence-free survival was evaluated as secondary outcome. RESULTS: ITF better defined the defect site, allowing a change in the treatment in 21 patients (25.3%), in whom nonconcordance was observed between the suspected radiologic site and the actual surgical site. Good agreement was found between the specific topographic localization (κ = 0.737; P < 0.0001), whereas fair agreement was observed considering the side of the defect (κ = 0.362; P = 0.0009) and correct identification of multiple sites (κ = 0.044; P = 0.666). The 10-year 96% estimate of recurrence-free survival confirmed the correct repair of the fistula site in most cases. CONCLUSIONS: Our data show the usefulness and safety of intraoperative ITF for management of patients affected by endonasal CSF leak. ITF improved the topographic diagnosis of the leak site, ensuring the best target reconstruction and very low recurrence rate.


Assuntos
Vazamento de Líquido Cefalorraquidiano , Base do Crânio , Vazamento de Líquido Cefalorraquidiano/diagnóstico por imagem , Vazamento de Líquido Cefalorraquidiano/cirurgia , Endoscopia/métodos , Fluoresceína , Humanos , Estudos Retrospectivos , Base do Crânio/diagnóstico por imagem , Base do Crânio/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...