Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Rev Assoc Med Bras (1992) ; 66(9): 1210-1216, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33027447

RESUMO

OBJECTIVE: To evaluate the value of EBUS-TBNA in the diagnosis of lung and mediastinal lesions. METHODS: Prospective cohort study that included 52 patients during a 2-year period (2016 to 2018) who underwent EBUS-TBNA. RESULTS: Among the 52 individuals submitted to the procedure, 22 (42.31%) patients were diagnosed with locally advanced lung cancer (N2 or N3 lymph node involvement). EBUS-TBNA confirmed the diagnosis of metastases from other extrathoracic tumors in the mediastinum or lung in 5 patients (9.61%), confirmed small cell lung cancer in 3 patients (5.76%), mediastinal sarcoidosis in 1 patient (1.92%), and reactive mediastinal lymph node in 8 patients (15.38%); insufficient results were found for 3 patients (5.76%). Based on these results, EBUS-TBNA avoided further subsequent surgical procedures in 39 of 52 patients (75%). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 86%, 100%, 100%, 77%, and 90%, respectively. No major complications were observed. CONCLUSIONS: EBUS-TBNA is a safe, effective, and valuable method. This technique can significantly reduce the rate of subsequent surgical procedures required for the diagnosis of lung and mediastinal lesions.


Assuntos
Endossonografia , Mediastino , Humanos , Mediastino/diagnóstico por imagem , Estadiamento de Neoplasias , Estudos Prospectivos , Ultrassonografia de Intervenção
2.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 66(9): 1210-1216, Sept. 2020. tab, graf
Artigo em Inglês | Sec. Est. Saúde SP, LILACS | ID: biblio-1136359

RESUMO

SUMMARY OBJECTIVE: To evaluate the value of EBUS-TBNA in the diagnosis of lung and mediastinal lesions. METHODS: Prospective cohort study that included 52 patients during a 2-year period (2016 to 2018) who underwent EBUS-TBNA. RESULTS: Among the 52 individuals submitted to the procedure, 22 (42.31%) patients were diagnosed with locally advanced lung cancer (N2 or N3 lymph node involvement). EBUS-TBNA confirmed the diagnosis of metastases from other extrathoracic tumors in the mediastinum or lung in 5 patients (9.61%), confirmed small cell lung cancer in 3 patients (5.76%), mediastinal sarcoidosis in 1 patient (1.92%), and reactive mediastinal lymph node in 8 patients (15.38%); insufficient results were found for 3 patients (5.76%). Based on these results, EBUS-TBNA avoided further subsequent surgical procedures in 39 of 52 patients (75%). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 86%, 100%, 100%, 77%, and 90%, respectively. No major complications were observed. CONCLUSIONS: EBUS-TBNA is a safe, effective, and valuable method. This technique can significantly reduce the rate of subsequent surgical procedures required for the diagnosis of lung and mediastinal lesions.


RESUMO OBJETIVO: Avaliar a importância da ecoendoscopia endobrônquica com punção por agulha fina (Ebus-TBNA) no diagnóstico das lesões pulmonares e mediastinais. MÉTODOS: Estudo prospectivo e do tipo coorte, no qual foram incluídos 52 pacientes, durante o período de dois anos (2016 a 2018), submetidos ao procedimento de Ebus-TBNA. RESULTADOS: Do total de 52 indivíduos submetidos ao procedimento, 22 (42,31%) pacientes foram diagnosticados com neoplasia pulmonar localmente avançada (N2 ou N3). O método confirmou o diagnóstico de metástases de outros tumores extratorácicos no mediastino ou pulmão em cinco pacientes (9,61%), três pacientes (5,76%) com carcinoma de pequenas células, um paciente (1,92%) com sarcoidose, oito pacientes (15,38%) com linfonodomegalias reacionais/inflamatórias e resultado insuficiente em três pacientes (5,76%). O Ebus-TBNA evitou a realização de outros procedimentos cirúrgicos subsequentes em 39 de 52 (75%) pacientes. Foram calculados os valores de sensibilidade de 86%, especificidade de 100%, valor preditivo positivo de 100%, valor preditivo negativo de 77% e acurácia de 90%. Não foram observadas complicações maiores pelo método neste estudo. CONCLUSÃO: O Ebus-TBNA é um método seguro, eficaz e de relevante importância. Este exame pode reduzir significativamente o número de procedimentos invasivos subsequentes necessários para o diagnóstico das lesões pulmonares e mediastinais.


Assuntos
Humanos , Endossonografia , Mediastino/diagnóstico por imagem , Estudos Prospectivos , Ultrassonografia de Intervenção , Estadiamento de Neoplasias
3.
Einstein (Sao Paulo) ; 17(4): eMD5157, 2019.
Artigo em Inglês, Português | MEDLINE | ID: mdl-31826074

RESUMO

Elastography is a widely used procedure in conventional ultrasonography that has recently been incorporated in echoendoscopy. This is an innovative and promising technology that aims to increase the negative predictive value of endoscopic ultrasonography and fine-needle aspiration punctures. It is useful for directing punctures in suspect areas and, consequently, improves diagnostic performance. This is a non-invasive technique, easy to perform, without additional costs or complications. The main indications are the analysis of solid pancreatic masses, lymph nodes, subepithelial lesions, lesions in the left hepatic lobe and in the left adrenal. Negative or inconclusive cases of fine-needle aspiration can be submitted to elastography when there is a strong suspicion of malignancy. Elastography has a high precision for the differential diagnosis of solid masses and in difficult-to-access anatomic sites, as well as in mediastinal lymph nodes and pancreatic tumors. The procedure is based on the degree of tissue elasticity measurement, with a good correlation between the elasticity index and histopathological features. We report the case of four patients evaluated by echoendoscopy and qualitative elastography who had differential diagnoses in mediastinal lymph nodes: sarcoidosis, lymphoma, histoplasmosis and esophageal neoplasia.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Endossonografia/métodos , Linfonodos/diagnóstico por imagem , Linfoma não Hodgkin/diagnóstico por imagem , Sarcoidose/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Adulto , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
4.
Endosc Ultrasound ; 6(6): 359-368, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29251269

RESUMO

BACKGROUND AND OBJECTIVES: At the time of its introduction in the early 80s, endoscopic ultrasonography (EUS) was indicated for diagnostic purposes. Recently, EUS has been employed to assist or to be the main platform of complex therapeutic interventions. METHODS: From a series of relevant new topics in the literature and based on the need to complement the I Brazilian consensus on EUS, twenty experienced endosonographers identified and reviewed the pertinent literature in databases. The quality of evidence, strength of recommendations, and level of consensus were graded and voted on. RESULTS: Consensus was reached for eight relevant topics: treatment of gastric varices, staging of nonsmall cell lung cancer, biliary drainage, tissue sampling of subepithelial lesions (SELs), treatment of pancreatic fluid collections, tissue sampling of pancreatic solid lesions, celiac neurolysis, and evaluation of the incidental pancreatic cysts. CONCLUSIONS: There is a high level of evidence for staging of nonsmall cell lung cancer; biopsy of SELs as the safest method; unilateral and bilateral injection techniques are equivalent for EUS-guided celiac neurolysis, and in patients with visible ganglia, celiac ganglia neurolysis appears to lead to better results. There is a moderate level of evidence for: yield of tissue sampling of pancreatic solid lesions is not influenced by the needle shape, gauge, or employed aspiration technique; EUS-guided and percutaneous biliary drainage present similar clinical success and adverse event rates; plastic and metallic stents are equivalent in the EUS-guided treatment of pancreatic pseudocyst. There is a low level of evidence in the routine use of EUS-guided treatment of gastric varices.

6.
J Thorac Dis ; 7(10): E505-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26623131

RESUMO

Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has become a minimally invasive tool with excellent diagnostic accuracy and low risk of complications in the diagnosis of thoracic diseases, including lung cancers and primary mediastinal lesions. Occasionally, EBUS-TBNA may be useful in identifying thoracic metastasis from distant tumors. Here we report an interesting and rare case of mediastinal metastasis of ovarian carcinoma diagnosed by EBUS-TBNA.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...