1.
J Int Med Res ; 36(1): 147-51, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18304413

RESUMO

During acute ischaemia the N-terminal site of albumin is altered, reducing its binding capacity; the modified protein is termed ischaemia-modified albumin (IMA). IMA is a sensitive marker of acute myocardial ischaemia but its diagnostic value in chronic angina pectoris patients is unclear. We investigated changes in blood levels of IMA during myocardial perfusion scintigraphy in patients with chronic angina pectoris in a study including 26 male and 20 female patients, with mean age 60 years. Technetium 99m perfusion imaging detected myocardial ischaemia in 26 patients. Coronary angiography was carried out in these 26 ischaemic patients. Mean IMA values at rest and peak exercise were significantly higher in the ischaemic than the nonischaemic group. All IMA values were considered negative for cardiac ischaemia. Peak exercise IMA was significantly lower than the pre-exercise level only in the non-ischaemic group. IMA measurements during myocardial perfusion scintigraphy are not helpful in the diagnosis of myocardial ischaemia in patients with stable angina pectoris.


Assuntos
Angina Pectoris/diagnóstico , Biomarcadores/análise , Isquemia Miocárdica/diagnóstico , Reperfusão Miocárdica , Cintilografia/métodos , Albumina Sérica/análise , Angina Pectoris/sangue , Doença Crônica , Angiografia Coronária , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/sangue , Valor Preditivo dos Testes , Tecnécio
2.
Brain Dev ; 21(2): 99-102, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10206526

RESUMO

Sympathetic skin response (SSR) and RR interval variation (RRIV) are used commonly for the assessment of sympathetic and parasympathetic nervous system function, respectively. We determined the normal values of SSR and RRIV in 23 (14 females, nine males) Turkish children aged 5 to 14 (mean 9.86, SD 2.48) years. SSR was recorded on the hands and feet during the electrical stimulation of both median and posterior tibial nerves, respectively. Similar response was elicited on both feet during the stimulation of the right median nerve. RRIV testing was performed during rest on the supine position and deep inspiration at a frequency of 6 times/min. The SSR was elicited in all children. The mean SSR latencies recorded on the feet during the stimulation of median or posterior tibial nerve were significantly more prolonged than those recorded at the hands (P < 0.001). There was no significant difference between the mean latencies of SSR recorded at the ipsilateral and contralateral palms or soles. The mean latencies recorded at the sole during stimulation of the median nerve were not significantly different compared to those that recorded at the sole during the posterior tibial nerve (P > 0.05). The SSR amplitudes were not assessed because of great variability and rapid habituation. The mean RRIV (46.54+/-11.29%) during deep breathing was significantly increased as compared to that (35.90+/-10.63%) during rest (P < 0.003). As a result, SSR and RRIV are preferred non-invasive tests for evaluation of autonomic nervous system in children. The SSR is useful and reliable if it is obtained in the optimum technical conditions. Further research is necessary to establish strict criteria for abnormality.


Assuntos
Frequência Cardíaca/fisiologia , Pele/inervação , Sistema Nervoso Simpático/fisiologia , Adolescente , Criança , Pré-Escolar , Estimulação Elétrica , Feminino , , Mãos , Humanos , Masculino , Nervo Mediano/fisiologia , Tempo de Reação/fisiologia , Valores de Referência , Nervo Tibial/fisiologia