Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pract Lab Med ; 10: 15-20, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29234708

RESUMO

We present a simple and fast high-performance liquid chromatography method with fluorescence detection for the determination of the antiepileptic drug perampanel in human plasma. The chromatographic separation was performed on a Kinetex PFP (100 × 2.6 mm, 4.6 µm) column, using a mobile phase of sodium acetate 0.03 M pH 3.7 and acetonitrile (40/60, v/v), at a flow rate of 0.8 mL/min. Total chromatography time for each run was 5 min. Sample preparation (250 µL) involved only one simple precipitation step by acetonitrile spiked with mirtazapine as internal standard. The method was validated over a concentration range of 20-1000 ng/mL and successfully applied to measure perampanel concentrations in plasma samples obtained from patients with epilepsy. This assay combines the high specificity of fluorescence detection with a very simple and fast sample pretreatment and can offer real advantages over existing methods in terms of simplicity and transferability to a therapeutic drug monitoring setting.

2.
Epilepsy Res ; 122: 79-83, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26987080

RESUMO

Generic substitution of antiepileptic drugs (AEDs) is still a matter of controversy and concern among clinicians and patients. We aimed to assess intrasubject variation in plasma concentrations of lamotrigine (LTG), levetiracetam (LEV) and topiramate (TPM) after generic substitution compared with a stable brand-name drug regimen in a population of patients with epilepsy. A retrospective analysis was performed on prospectively collected and stored data from our therapeutic drug monitoring (TDM) database for the years 2009-2014. The main outcome variable was the proportion of patients who, after switching from branded to generic formulations, showed a greater than ±20% change in AED plasma concentrations compared to the proportion of control patients showing a change in AED plasma concentrations of the same extent while receiving stable branded formulations over repeated TDM tests. Fifty patients on LTG, 27 on LEV and 16 on TPM showing at least one TDM test while receiving generic products fulfilled the inclusion/exclusion criteria for the analysis and were compared with 200 control patients for LTG, 120 for LEV and 80 for TPM. The proportion of patients showing an intrasubject change greater than ±20% in AED plasma concentrations was similar in the brand name vs generic group compared with the control one for LTG (22% vs 33%) and LEV (44% vs 38%), while it was higher in the control group for TPM (41% vs 6%, p<0.01). These are the first data in the literature about the within-patient variation in steady-state plasma concentrations of a series of stable treatments with brand-name AEDs in a real clinical setting. In conclusion, a significant interday variability in intrapatient LTG, LEV and TPM plasma concentrations can be observed even in patients stabilized with the same brand name product over time. This suggests that any change in plasma AED concentration and possible related clinical effects after generic substitution may be not necessarily related to the switch. Our results should be confirmed by large, prospective, blinded, randomized controlled studies in people with epilepsy.


Assuntos
Anticonvulsivantes/administração & dosagem , Anticonvulsivantes/sangue , Substituição de Medicamentos , Medicamentos Genéricos/administração & dosagem , Medicamentos Genéricos/farmacocinética , Adulto , Análise Química do Sangue , Bases de Dados de Produtos Farmacêuticos , Epilepsia/sangue , Epilepsia/tratamento farmacológico , Feminino , Seguimentos , Frutose/administração & dosagem , Frutose/análogos & derivados , Frutose/sangue , Humanos , Pacientes Internados , Lamotrigina , Levetiracetam , Masculino , Pessoa de Meia-Idade , Piracetam/administração & dosagem , Piracetam/análogos & derivados , Piracetam/sangue , Estudos Prospectivos , Estudos Retrospectivos , Topiramato , Triazinas/administração & dosagem , Triazinas/sangue
3.
Ther Drug Monit ; 35(6): 849-52, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23942540

RESUMO

BACKGROUND: Lacosamide (LCM) is one of the newer antiepileptic drugs (AEDs) licensed as add-on treatment for partial epilepsy. Data on LCM pharmacokinetics and interactions are limited and partly contradictory. The purpose of this study was to assess the effect of concomitant AED therapy on steady state plasma concentrations of LCM in a population of patients with epilepsy. METHODS: Steady state plasma concentrations of LCM were assessed in a cohort of 75 consecutive patients with epilepsy referred to the Laboratory of Clinical Neuropharmacology for AED therapeutic monitoring over 16 months. Plasma LCM concentrations were measured by high-performance liquid chromatography with spectrophotometric detection. RESULTS: Median morning trough plasma concentration-to-weight-adjusted dose ratio of LCM [(mg/L)/(mg/kg/d)] was significantly reduced (0.94 versus 1.35, P < 0.001) in patients treated with LCM plus AED strong inducers of cytochrome P450 metabolism, namely, carbamazepine, phenobarbital, and phenytoin (group A, n = 33), compared with a pool of patients not comedicated with AED strong inducers, predominantly including oxcarbazepine, levetiracetam, lamotrigine, and valproic acid (group B, n = 42). The 2 groups were comparable for age, gender, weight, LCM daily dose, and dosing frequency. LCM plasma concentrations were linearly related to daily drug doses, regardless of concomitant AED therapy, over a dose range from 75 to 600 mg/d, although, at a given drug dose, a large interpatient variability was observed in matched, plasma drug concentration. CONCLUSIONS: Our findings confirm, in a real-patient clinical setting, preliminary evidence from randomized, clinical trials showing that carbamazepine, phenobarbital, or phenytoin significantly reduces the overall systemic exposure to LCM. From a practical point of view, patients on concomitant AED strong inducers may require a 30% higher dose of LCM compared with patients not receiving strongly inducing AED cotherapy, to achieve the same plasma drug concentration.


Assuntos
Acetamidas/sangue , Anticonvulsivantes/sangue , Cromatografia Líquida de Alta Pressão/métodos , Epilepsia/tratamento farmacológico , Acetamidas/administração & dosagem , Acetamidas/uso terapêutico , Adulto , Anticonvulsivantes/administração & dosagem , Anticonvulsivantes/uso terapêutico , Estudos de Coortes , Relação Dose-Resposta a Droga , Monitoramento de Medicamentos/métodos , Quimioterapia Combinada , Feminino , Humanos , Lacosamida , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Espectrofotometria/métodos , Adulto Jovem
4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(3-4): 461-5, 2010 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20005185

RESUMO

We present an implementation of a method we previously reported allowing the newer antiepileptic drugs (AEDs) rufinamide (RFN) and zonisamide (ZNS) to be simultaneously determined with lamotrigine (LTG), oxcarbazepine's (OXC) main active metabolite monohydroxycarbamazepine (MHD) and felbamate (FBM) in plasma of patients with epilepsy using high performance liquid chromatography (HPLC) with UV detection. Plasma samples (250 microL) were deproteinized by 1 mL acetonitrile spiked with citalopram as internal standard (I.S.). HPLC analysis was carried out on a Synergi 4 microm Hydro-RP, 250 mm x 4.6 mm I.D. column. The mobile phase was a mixture of potassium dihydrogen phosphate buffer (50 mM, pH 4.5), acetonitrile and methanol (65:26.2:8.8, v/v/v) at an isocratic flow rate of 0.8 mL/min. The UV detector was set at 210 nm. The chromatographic run lasted 19 min. Commonly coprescribed AEDs did not interfere with the assay. Calibration curves were linear for both AEDs over a range of 2-40 microg/mL for RFN and 2-80 microg/mL for ZNS. The limit of quantitation was 2 microg/mL for both analytes and the absolute recovery ranged from 97% to 103% for RFN, ZNS and the I.S. Intra- and interassay precision and accuracy were lower than 10% at all tested concentrations. The present study describes the first simple and validated method for RFN determination in plasma of patients with epilepsy. By grouping different new AEDs in the same assay the method can be advantageous for therapeutic drug monitoring (TDM).


Assuntos
Anticonvulsivantes/sangue , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Epilepsia/sangue , Raios Ultravioleta , Anticonvulsivantes/química , Carbamazepina/análogos & derivados , Carbamazepina/sangue , Carbamazepina/química , Felbamato , Humanos , Isoxazóis/sangue , Isoxazóis/química , Lamotrigina , Oxcarbazepina , Fenilcarbamatos/sangue , Fenilcarbamatos/química , Propilenoglicóis/sangue , Propilenoglicóis/química , Triazinas/sangue , Triazinas/química , Triazóis/sangue , Triazóis/química , Zonisamida
5.
J Chromatogr B Analyt Technol Biomed Life Sci ; 828(1-2): 113-7, 2005 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-16182617

RESUMO

A very simple and fast method has been developed and validated for simultaneous determination of the new generation antiepileptic drugs (AEDs) lamotrigine (LTG), oxcarbazepine's (OXC) main active metabolite monohydroxycarbamazepine and felbamate in plasma of patients with epilepsy using high-performance liquid chromatography (HPLC) with spectrophotometric detection. Plasma sample (500 microL) pre-treatment was based on simple deproteinization by acetonitrile. Liquid chromatographic analysis was carried out on a Synergi 4 microm Hydro-RP, 150 mm x 4 mm I.D. column, using a mixture of potassium dihydrogen phosphate buffer (50mM, pH 4.5) and acetonitrile/methanol (3/1) (65:35, v/v) as the mobile phase, at a flow rate of 1.0 mL/min. The UV detector was set at 210 nm. Calibration curves were linear (mean correlation coefficient >0.999 for all the three analytes) over a range of 1-20 mg/mL for lamotrigine, 2-40 microg/mL for monohydroxycarbamazepine and 10-120 microg/mL for felbamate. Both intra and interassay precision and accuracy were lower than 7.5% for all three analytes. Absolute recoveries ranged between 100 and 104%. The present procedure describes for the first time the simultaneous determination of these three new antiepileptic drugs. The simple sample pre-treatment, combined with the fast chromatographic run permit rapid processing of a large series of patient samples.


Assuntos
Anticonvulsivantes/sangue , Carbamazepina/análogos & derivados , Cromatografia Líquida de Alta Pressão/métodos , Dibenzazepinas/sangue , Epilepsia/sangue , Propilenoglicóis/sangue , Triazinas/sangue , Carbamazepina/análise , Carbamazepina/sangue , Monitoramento de Medicamentos , Felbamato , Humanos , Lamotrigina , Oxcarbazepina , Fenilcarbamatos , Espectrofotometria Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...