Phys Med ; 119: 103300, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38325222

RESUMO

PURPOSE: The aim of the present study, conducted by a working group of the Italian Association of Medical Physics (AIFM), was to define typical z-resolution values for different digital breast tomosynthesis (DBT) models to be used as a reference for quality control (QC). Currently, there are no typical values published in internationally agreed QC protocols. METHODS: To characterize the z-resolution of the DBT models, the full width at half maximum (FWHM) of the artifact spread function (ASF), a technical parameter that quantifies the signal intensity of a detail along reconstructed planes, was analyzed. Five different commercial phantoms, CIRS Model 011, CIRS Model 015, Modular DBT phantom, Pixmam 3-D, and Tomophan, were evaluated on reconstructed DBT images and 82 DBT systems (6 vendors, 9 models) in use at 39 centers in Italy were involved. RESULTS: The ASF was found to be dependent on the detail size, the DBT angular acquisition range, the reconstruction algorithm and applied image processing. In particular, a progressively greater signal spread was observed as the detail size increased and the acquisition angle decreased. However, a clear correlation between signal spread and angular range width was not observed due to the different signal reconstruction and image processing strategies implemented in the algorithms developed by the vendors studied. CONCLUSIONS: The analysis led to the identification of typical z-resolution values for different DBT model-phantom configurations that could be used as a reference during a QC program.


Assuntos
Processamento de Imagem Assistida por Computador , Mamografia , Mamografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Artefatos , Algoritmos
2.
Phys Med ; 72: 7-15, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32179407

RESUMO

Conversion factors used to estimate effective (E) and organ doses (HT) from air Kerma area product (KAP) are required to estimate population doses in percutaneous transhepatic biliary drainage (PTBD) and trans arterial chemoembolization (TACE) interventional procedures. In this study, E and HT for ten critical organs/tissues, were derived in 64 PTBD and 48 TACE procedures and in 14,540 irradiation events from dosimetric, technical and geometrical information included in the radiation dose structured report using the PCXMC Monte Carlo model, and the ICRP 103 organ weighting factors. Conversion factors of: 0.13; 0.19; 0.26 and 0.32 mSv Gy-1 cm-2 were established for irradiation events characterized by a Cu filtration of 0.0; 0.1; 0.4 and 0.9 mm, respectively. While a single coefficient of conversion is not able to provide estimates of E with enough accuracy, a high agreement is obtained between E estimated through Monte Carlo methods and E estimated through E/KAP conversion factors accounting separately for the different modes of fluoroscopy and the fluorography component of the procedures. An algorithm for the estimation of effective and organ doses from KAP has been established in biliary procedures which considers the Cu filtration in the X-ray irradiation events. A similar algorithm could be easily extended to other interventional procedures and incorporated in radiation dose monitoring systems to provide dosimetric estimates automatically with enough accuracy to assess population doses.


Assuntos
Artérias , Quimioembolização Terapêutica/métodos , Drenagem/métodos , Doses de Radiação , Idoso , Feminino , Humanos , Masculino , Método de Monte Carlo
3.
Phys Med ; 49: 34-39, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29866340

RESUMO

According to the EU directive 2013/59, the computed tomography (CT) equipments shall be able to inform the practitioner of parameters for assessing the patient dose. The aim of this study was to measure the accuracy of the CTDI100 with respect to the values stipulated in the manufacturer manual for different manufacturers/models of CT and to assess the impact of acquisition parameters on CTDI100 accuracy. Ten CT from 4 different manufacturers were included in the study. The discrepancy with the manufacturer value CTDI100 was checked with a dosimeter with traceable calibration. Manufacturer values for the CTDI100 were derived from the equipment's manual. The impact of the kVp, CT model, primary collimation and phantom size on the discrepancy of the CTDI100, was assessed by a four-way ANOVA. All the factors had a statistically significant impact on CTDI100 discrepancy (P < 0.05). In a head to head comparison, the greater discrepancies were found on average for 80 kV (15.4 ±â€¯10.7%), sixteen channels CT (10.3 ±â€¯5.1%) and for thick collimations (13.2 ±â€¯6.8%), whilst no significant differences were found between head and body phantoms. For sixteen channels CT and acquisition protocols involving the use of low kV or thick primary collimation, the discrepancies with the manufacturer value CTDI100 can be higher than 20%, which is the suspension level indicated in the EC RP N.162 Publication. This suggests the need of individual calibration of CT X-ray tubes by the manufacturers and the necessity of including this check in the quality control programs for CT.


Assuntos
Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação , Calibragem , Doses de Radiação
4.
Phys Med ; 42: 189-196, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29173914

RESUMO

To derive effective dose (E), organ dose (HT) and conversion factors with the air kerma area product (KAP) in coronary angiography (CA) and percutaneous coronary intervention (PCI) by the radial route, using the ICRP 103 tissue weighting factors. The study included 34 patients referred for CA and 31 for PCI. E and HT were derived from in-the-field KAP measurements using Montecarlo methods. Median KAP of 23.2 and 56.8Gycm2 and E of 6.9 and 20.0mSv were found for CA and PCI, respectively. Mean KAP and E were significantly higher in males than in females (52.4±40.0 vs 32.3±16.6Gycm2; p=0.02) and (16.8±13.6 vs 10.7±5.8mSv; p=0.04). KAP (r=0.39; p=0.001) and E (r=0.34; p=0.005) showed a significant correlation with the patient's weight. Conversion factors between KAP and E (E/KAP) were 0.30±0.04mSvGy-1cm-2 for CA and 0.33±0.05mSvGy-1cm-2 for PCI. No significant differences in the E/KAP between males and females were found (0.31±0.05 vs 0.33±0.05; p=0.08). Again, no significant correlation was found between E/KAP and patient's weight (r=0.23; p=0.07). The correlation between E and KAP was excellent for CA (r=0.99) and PCI (r=0.96). The correlation between HT and KAP ranged from r=0.87 to r=1 and from r=0.71 to r=0.98 for CA and PCI, respectively. A single factor, the total KAP, could be used for a specific acquisition protocol to reliably estimate E and HT without the need of a patient's specific analysis. Conversion factors might be installation, X-ray beam quality or protocol dependent.


Assuntos
Angiografia Coronária/métodos , Intervenção Coronária Percutânea/métodos , Doses de Radiação , Proteção Radiológica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Peso Corporal , Protocolos Clínicos , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Método de Monte Carlo , Estudos Prospectivos , Lesões por Radiação/prevenção & controle , Radiometria/métodos , Fatores Sexuais
5.
Phys Med Biol ; 51(3): 695-702, 2006 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-16424589

RESUMO

Intraoperative electron beam radiotherapy is increasingly performed using mobile linac delivering therapeutic radiation doses in unshielded operating rooms. While no special neutron-shielding problem should arise for operation at 10 MeV or less, it is not clear whether this holds true for operation at higher energies. This paper reports the measured neutron production from a Mobetron mobile electron linac, operated at 12 MeV, and compares the results with those from a conventional linac, also operated at 12 MeV in electron mode. Neutron leakage measurements were performed by means of passive bubble detectors in the scattering foil, patient and floor planes. Neutron dose equivalent rates per unit of electron dose delivered by the Mobetron at its normal treatment distance (50 cm SSD) were 0.33 microSv Gy(-1) at the accelerator head, 0.18 microSv Gy(-1) in the patient plane at 15 cm from the beam axis and 0.31 microSv Gy(-1) at the floor plane, on the beam axis and under the beam stopper. For a weekly workload of 250 Gy, the weekly neutron dose equivalents at 12 MeV for the Mobetron at a distance of 300 cm from the scattering foil were 14.3 and 1.7 microSv/week for floor below and adjoining areas on the same floor, respectively. Neutron dose equivalent rates generated from Mobetron are at least one order of magnitude lower than ones produced by a conventional linac operated at the same energy in electron mode. Mobetron can be used at 12 MeV in an unshielded operating room for a weekly workload of up to 250 Gy if the bremsstrahlung x-rays are shielded to negligible levels.


Assuntos
Neoplasias/radioterapia , Neoplasias/cirurgia , Nêutrons , Aceleradores de Partículas , Radioterapia/instrumentação , Radioterapia/métodos , Terapia Combinada , Elétrons , Humanos , Doses de Radiação , Monitoramento de Radiação , Radiometria , Dosagem Radioterapêutica , Espalhamento de Radiação , Raios X