1.
Odontology ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38977543

RESUMO

This scoping review aims to summarize current research to assess the impact of heating on the chemo-physical properties of bioceramic sealers. Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Extension for Scoping Reviews guidelines, a comprehensive literature search was conducted in April 2024 across PubMed and Scopus databases. Inclusion criteria referred to all study types evaluating the effect of heating temperature on bioceramic sealers' properties, with no language or time restrictions applied. Studies were independently screened by two reviewers, and relevant data were extracted and synthesized qualitatively. Out of 91 initially identified studies, 19 met the eligibility criteria for inclusion in the qualitative synthesis. The selected studies ranged from 2014 to 2024 and comprised laboratory-based investigations. Various bioceramic sealers, including EndoSequence BC Sealer, BioRoot RCS, and TotalFill BC, were analyzed across different heating techniques. The findings revealed divergent responses of bioceramic sealers to heat, with some demonstrating stability while others exhibited alterations in properties such as flow, setting time, and chemical composition. The impact of heat on bioceramic sealers depends on the sealer's composition and laboratory setting. While some sealers are affected significantly, others remain stable. Clinicians should carefully consider these factors when bioceramic sealers are used with warm obturation techniques, but caution is needed as real-world conditions may vary. Integrating laboratory results with clinical evidence is essential for improving treatment efficacy and patient care.

2.
Int Dent J ; 74(4): 855-861, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38350803

RESUMO

OBJECTIVE: This is the first study evaluating the impact of different pecking motion depths on dynamic cyclic fatigue resistance of different endodontic instruments. METHODS: Four nickel-titanium systems (Hyflex EDM OneFile 25/. ∼; Rotate 25/0.6; Mtwo 25/0.6; Reciproc Blue R25) were tested. Forty instruments from each group were subjected to 4 different pecking movements to evaluate their cyclic fatigue resistance. The distances for the pecking motion were 3-mm forward and backward, 1-mm (3-mm forward and 2-mm backward), 2-mm (4-mm forward and 2-mm backward), and 3-mm (5-mm forward and 2-mm backward). Speeds were 100 and 200 mm/min for the descending and ascending motion, respectively. The times to fracture (TtF) in seconds were recorded for each instrument. Data were statistically analysed by using 2-way ANOVA and Bonferroni multiple comparison post hoc test (P < .05). RESULTS: All instruments had a significant increase in cyclic fatigue resistance during the forward dynamic motion compared with the axial continuous. Overall, the heat-treated instruments reported higher fatigue strength than the untreated files (P < .05). Reciproc Blue and Hyflex EDM showed higher TtF in the forward movements of 1-/2-mm and 2-mm (P < .05), respectively while Mtwo 25.06 and Rotate 25.06 in the forward movement of 3-mm (P < .05). CONCLUSIONS: Within the limits of this in vitro study, the pecking motion depths had varying impacts on the cyclic fatigue resistance of instruments. Reciproc Blue and Hyflex EDM performed significantly better with pecking motions of 1-and 2-mm. Improving endodontic instrument durability through specific pecking depths has the potential for improving clinical performance and reducing instrument failures.


Assuntos
Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular , Técnicas In Vitro , Preparo de Canal Radicular/instrumentação , Instrumentos Odontológicos , Titânio , Desenho de Equipamento , Níquel , Movimento (Física) , Análise do Estresse Dentário , Humanos , Estresse Mecânico
3.
Clin Exp Dent Res ; 10(1): e811, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38053521

RESUMO

OBJECTIVES: The aim of this study is to determine the cyclic fatigue resistance of Mtwo Minimal in static and dynamic tests, with different amplitudes of pecking movements, at intracanal temperature. MATERIALS AND METHODS: Two hundred new 25-mm Mtwo Minimal rotary files (#10/0.035, #17.5/0.045, #25/0.05, #40/0.03, #45/0.03) were tested in static and dynamic cyclic fatigue tests at 35°C (±1°C). An artificial stainless-steel canal was used. In the dynamic mode, axial movements were set at 1 and 3 mm. The number of cycles to fracture (NCF) was recorded and statistically analyzed by one-way analysis of variance (p < 0.05). RESULTS: The 3-mm dynamic test showed significantly increased NCF than the other tests for the #10/0.035, #17.5/0.045, and #25/0.05 files (p < 0.05). The #40/0.03 and #45/0.03 files showed no significant differences in all the tests (p > 0.05). CONCLUSION: Mtwo Minimal showed higher cyclic fatigue resistance in the dynamic test than the static test, except for the larger instruments. The 3-mm pecking amplitude increased the cyclic fatigue resistance of the smaller instruments.


Assuntos
Níquel , Titânio , Ligas
4.
Aust Endod J ; 49(3): 592-598, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37592880

RESUMO

The aim of this study was to compare the cyclic fatigue resistance of nickel-titanium instruments inside single and double-curved canals at different temperatures. 160 HyFlex EDM #20.05 (HEDM), VDW.ROTATE #20.05 and #25.06, Mtwo #25.06 were randomised (n = 10) for the dynamic cyclic fatigue tests according to the curvature (i.e. single and double) at 20° ± 1°C and 35° ± 1°C. The number of cycles to fracture (NCF) was analysed by two-way ANOVA with p < 0.05. Fatigue resistance of all instruments significantly decreased at body temperature in single and double curvatures, except for HEDM in double curvature. The NCF was significantly lower in double curvature than single at both temperatures for all files, except for VDW.ROTATE #20.05 at 35° ± 1°C. Within the study limitations, temperature significantly impaired cyclic fatigue resistance of all files except HEDM #20.05 in double curvature. Similarly, double curvature had a detrimental effect on cyclic fatigue resistance of all files except for VDW.ROTATE #20.05 at body temperature.


Assuntos
Instrumentos Odontológicos , Níquel , Titânio , Temperatura Corporal , Ligas Dentárias , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular , Resistência à Flexão
5.
Materials (Basel) ; 15(19)2022 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-36233910

RESUMO

We compared the mechanical properties of 2Shape mini TS2 (Micro-Mega, Besançon, France) obtained from 1.0 diameter nickel-titanium (NiTi) wires and 2Shape TS2 from 1.2 diameter nickel-titanium (NiTi) wires differently thermally treated at room and body temperature. We used 120 NiTi TS2 1.0 and TS2 1.2 files made from controlled memory (CM) wire and T-wire (n = 10). Cyclic fatigue resistance was tested by recording the number of cycles to fracture (NCF) at room and body temperatures using a customized testing device. Maximum torque and angle of rotation at failure were recorded, according to ISO 3630-1. Data were analyzed by a two-way ANOVA (p < 0.05). The CM-wire files had significantly higher NCFs at both temperatures, independent of wire dimensions. Testing at body temperature negatively affected cyclic fatigue of all files. The 1.0-mm diameter T-wire instruments showed higher NCF than the 1.2-mm diameter, whereas no significant differences emerged between the two CM wires at either temperature. The maximum torque was not significantly different across files. The TS2 CM-wire files showed significantly higher angular rotation to fracture than T-wire files. The TS2 CM-wire prototypes showed higher cyclic fatigue resistance than T-wire prototypes, regardless of wire size, exhibiting suitable torsional properties. Torsional behavior appears to not be affected by NiTi wire size.