2.
J Cardiovasc Electrophysiol ; 34(6): 1431-1440, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36786511

RESUMO

INTRODUCTION: It is not known whether the optimal atrioventricular (AVopt ) delay varies between left ventricular (LV) pacing site during endocardial biventricular pacing (BiVP) and may therefore needs consideration. METHODS: We assessed the hemodynamic AVopt in patients with chronic heart failure undergoing endocardial LV lead implantation. AVopt was assessed during atrio-BiVP with a "roving LV lead." Up to four locations were studied: mid-lateral wall, mid-septum (or a close alternative), site of greatest hemodynamic improvement, and LV lead implant site. The AVopt was compared to a fixed AV delay of 180 ms. RESULTS: Seventeen patients were included (12 male, aged 66.5 ± 12.8 years, ejection fraction 26 ± 7%, 16 left bundle branch block or high percentage of right ventricular pacing [RVP], QRS duration 167 ± 27 ms). In most locations (62/63), AVopt increased systolic blood pressure during BiVP compared with RVP (relative improvement 6 mmHg, interquartile range [IQR] 4-9 mmHg). Compared to a fixed AV delay, the hemodynamic improvement at AVopt was higher (1 mmHg, IQR 0.2-2.6 mmHg, p < .001). Within most patients (16/17), we observed a difference in AVopt between pacing sites (median paced AVopt 209 ms, IQR 117-250). Within this range, the hemodynamic impact of these differences was small (median loss 0.6 mmHg, IQR 0.1-2.6 mmHg). CONCLUSION: Within a patient, different endocardial LV lead locations have slightly different hemodynamic AVopt which are superior to a fixed AV delay. The hemodynamic consequence of applying an optimum from a different lead location is small.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Terapia de Ressincronização Cardíaca/efeitos adversos , Hemodinâmica/fisiologia , Bloqueio de Ramo , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Função Ventricular Esquerda/fisiologia , Estimulação Cardíaca Artificial
3.
Int J Cardiol Heart Vasc ; 44: 101171, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36660200

RESUMO

Introduction: Conduction system pacing (CSP), consisting of His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) is a rapidly developing field. These pacing techniques result in single lead left ventricular resynchronisation. Understanding of the associated learning curve of the two techniques is an important consideration for new implanters/implanting centres. Methods: We conducted a review of the first 30 cases of both HBP and LBBAP at The Royal Brompton Hospital. The procedural duration and fluoroscopy time were used as surrogates for the learning curve of each technique. Results: Patient characteristics were similar in HBP and LBBAP groups; LV ejection fraction (46% vs 54%, p = 0.08), pre-procedural QRS duration (119 ms vs 128 ms, p = 0.32).Mean procedural duration was shorter for LBBAP than for HBP (87 vs 107mins, p = 0.04) and the drop in procedural duration was more marked in LBBAP, plateauing and remaining low at 80mins after the initial 10 cases. Fluoroscopic screening time mirrored procedural duration (8 min vs 16 min, p < 0.01). Discussion/Conclusion: Our data suggest that the CSP learning curve was shorter for LBBAP than for HBP and appears to plateaux after the first 10 cases, however the HBP learning curve is longer with continued improvement over the first 30 cases. The shorter learning curve of LBBAP in conjunction with the superior electrical parameters and simplified programming mean the establishment of a CSP program is potentially easier with LBBAP compared to with HBP.

4.
Pacing Clin Electrophysiol ; 45(4): 481-490, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35043404

RESUMO

BACKGROUND: Conventional superior access for cardiac implantable electronic devices (CIEDs) is not always possible and femoral CIEDs (F-CIED) are an alternative option when leadless systems are not suitable. The long-term outcomes and extraction experiences with F-CIEDs, in particular complex F-CIED (ICD/CRT devices), remain poorly understood. METHODS: Patients referred for F-CIEDs implantation between 2002 and 2019 at two tertiary centers were included. Early complications were defined as ≤30 days following implant and late complications >30 days. RESULTS: Thirty-one patients (66% male; age 56 ± 20 years; 35% [11] patients with congenital heart disease) were implanted with F-CIEDs (10 ICD/CRT and 21 pacemakers). Early complications were observed in 6.5% of patients: two lead displacements. Late complications at 6.8 ± 4.4 years occurred in 29.0% of patients. This was higher with complex F-CIED compared to simple F-CIED (60.0% vs. 14.3%, p = .02). Late complications were predominantly generator site related (n = 8, 25.8%) including seven infections/erosions and one generator migration. Eight femoral generators and 14 leads (median duration in situ seven [range 6-11] years) were extracted without complication. CONCLUSIONS: Procedural success with F-CIEDs is high with clinically acceptable early complication rates. There is a notable risk of late complications, particularly involving the generator site of complex devices following repeat femoral procedures. Extraction of chronic F-CIED in experienced centers is feasible and safe.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Marca-Passo Artificial , Adulto , Idoso , Eletrônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Heart Rhythm ; 19(1): 61-69, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34583060

RESUMO

BACKGROUND: A novel aggregated multiposition noncontact mapping (AMP-NCM) algorithm is proposed to diagnose cardiac arrhythmias. OBJECTIVE: The purpose of this study was to computationally determine an accuracy threshold and to compare the accuracy and clinical utility of AMP-NCM to gold standard contact mapping. METHODS: In a cellular automata model, the number of catheter positions and chamber coverage were varied to establish accuracy requirements for clinically relevant AMP-NCM. This guided the clinical study protocol. In a prospective cohort of patients with atrial tachycardia (AT), noncontact mapping (NCM) recordings from a single position (SP) and multiple positions were compared to contact mapping with a high-density multipolar catheter using morphology and timing differences of reconstructed signals. Identification of AT mechanisms and ablation targets using both AMP-NCM and contact mapping were randomly evaluated by 5 blinded reviewers. RESULTS: AMP-NCM accuracy was asymptotic at 60 catheter positions in computational modeling. Twenty patients (age 65 ± 12 years; 19 male) with 26 ATs (5 focal, 21 reentrant) were studied. Morphologic correlation of signals derived from AMP-NCM was significantly better than those from SP-NCM compared to contact signals (median 0.93 vs 0.76; P <.001). AMP-NCM generated maps more rapidly than contact mapping (3 ± 1 minutes vs 13 ± 6 minutes; P <.001) and correctly diagnosed AT mechanisms in 25 of 26 maps (96%). Overall, 80% of arrhythmia mechanisms were correctly identified using AMP-NCM by blinded reviewers. CONCLUSION: Once 60 catheter positions were achieved, AMP-NCM successfully diagnosed mechanisms of AT and identified treatment sites equal to gold standard contact mapping in 3 minutes of procedural time.


Assuntos
Simulação por Computador , Mapeamento Epicárdico , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Idoso , Algoritmos , Feminino , Humanos , Masculino , Estudos Prospectivos
7.
Heart Rhythm ; 18(6): 862-870, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33610744

RESUMO

BACKGROUND: Noncontact charge-density mapping allows rapid real-time global mapping of atrial fibrillation (AF), offering the opportunity for a personalized ablation strategy. OBJECTIVE: The purpose of this study was to compare the 2-year outcome of an individualized strategy consisting of pulmonary vein isolation (PVI) plus core-to-boundary ablation (targeting the conduction pattern core with an extension to the nearest nonconducting boundary) guided by charge-density mapping, with an empirical PVI plus posterior wall electrical isolation (PWI) strategy. METHODS: Forty patients (age 62 ± 12 years; 29 male) with persistent AF (10 ± 5 months) prospectively underwent charge-density mapping-guided PVI, followed by core-to-boundary stepwise ablation until termination of AF or depletion of identified cores. Freedom from AF/atrial tachycardia (AT) at 24 months was compared with a propensity score-matched control group of 80 patients with empirical PVI + PWI guided by conventional contact mapping. RESULTS: Acute AF termination occurred in 8 of 40 patients after charge-density mapping-guided PVI alone and in 21 of the remaining 32 patients after core-to-boundary ablation in the study cohort, compared with 8 of 80 (10%) in the control cohort (P <.001). On average, 2.2 ± 0.6 cores were ablated post-PVI before acute AF termination. At 24 months, freedom from AF/AT after a single procedure was 68% in the study group vs 46% in the control group (P = .043). CONCLUSION: An individualized ablation strategy consisting of PVI plus core-to-boundary ablation guided by noncontact charge-density mapping is a feasible and effective strategy for treating persistent AF, with a favorable 24-month outcome.


Assuntos
Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/normas , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/normas , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Prospectivos , Recidiva , Fatores de Tempo , Resultado do Tratamento
8.
Int J Cardiol ; 175(2): 328-32, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-24985070

RESUMO

INTRODUCTION: Stroke associated with atrial fibrillation (AF) is more frequent in heart failure. It is unknown what variables predict future AF in these patients and how AF might evolve over time. We investigated this in patients with implantable cardiac defibrillators (ICD) where AF detection is optimal. METHODS: Single centre, retrospective, observational cohort study. All ischaemic cardiomyopathy patients with dual chamber, primary prevention ICD implants between Aug 2003 and Dec 2009 were screened and included if at implant, they had no known AF history. Nine variables were analysed. AF was defined as any atrial tachyarrhythmia ≥180 bpm and ≥30 s. Multivariable, binary logistic regression models were built by adding variables significant in the univariate models. Variables were retained in the final multivariate models if p<0.05. RESULTS: n=197 met the inclusion criteria (85.8% male, median age: 66.8 years). After median follow-up for 2.8 years, 44.2% developed AF. After univariate analysis, the baseline variables associated with AF after implant were age, NYHA class and renal impairment (RI, defined eGFR<60 ml/min/1.73 m2) (p<0.05). After multivariable analysis, the only variable which was associated with AF was RI (HR: 2.04 (CI: 1.10-3.79)). Two baseline variables were independently associated with all-cause mortality: RI (HR: 2.42 (1.14-5.12)) and non-white ethnicity. CONCLUSION: RI at time of implant was independently associated with both future AF and all-cause mortality during long-term follow-up. RI was a stronger predictor of AF than age. Those patients with heart failure and RI should be regularly screened for asymptomatic AF, regardless of age, to ensure that stroke prophylaxis may be initiated.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
9.
Heart Rhythm ; 11(11): 1862-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24960268

RESUMO

BACKGROUND: Catheter ablation of atrial fibrillation (AF) is a physically demanding procedure for the operator, involving radiation exposure, and has limited success rates. Remote robotic navigation (RRN) may offer benefit to the procedure, though only 1 previous small randomized trial has assessed this. OBJECTIVE: This study aimed to investigate the impact of RRN on 1-year single-procedure success rates. METHODS: RRN was compared to manual ablation in a randomized control trial setting by using an intention-to-treat analysis. RESULTS: A total of 157 patients underwent ablation (116/157 (74%) persistent AF; 67/116 (58%) of these long-standing persistent AF). There were no significant differences between the RRN and manual groups with respect to 1-year single-procedure success rates (19/78 (24%) and 26/78 (33%), respectively; P = .29), acute wide area circumferential ablation reconnection rates, complication rates, or procedure times. On multivariable analysis, fluoroscopy times were significantly shorter in the RRN group. The number of catheter displacements during ablation was lower in the RRN group, as was subjectively assessed operator fatigue. The crossover rate from RRN to manual ablation was 11/78 (14%), mainly secondary to technical problems with the RRN system. A learning curve was evident for RRN ablation: the fluoroscopy and procedure times were significantly lower after the first 10 cases in an operator's experience. CONCLUSION: This randomized trial showed no difference in the success rate for catheter ablation of AF between a RRN and manual approach. The results highlight the learning curve for RRN ablation and suggest that the use of this technology leads to an improvement in fluoroscopy times, catheter stability, and operator fatigue.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento