Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Front Pharmacol ; 13: 919035, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36091768

RESUMO

Pancreatic cancer is accompanied by poor prognosis and accounts for a significant number of deaths every year. Since Psoralea corylifolia L. (PCL) possesses a broad spectrum of bioactivities, it is commonly used in traditional Chinese medicine. The study explored potential antitumor agents of PCL and underlying mechanisms in vitro and vivo. Based on network pharmacology, bioinformatics, and molecular docking, we considered isobavachalcone (IBC) as a valuable compound. The activity and potential mechanisms of IBC were investigated by RT-qPCR, immunohistochemistry, immunofluorescence, and flow cytometry. It was confirmed that IBC could inhibit Panc 02 cell proliferation and induce apoptosis via increasing the production of reactive oxygen species. IBC could attenuate the weight of solid tumors, increase CD8+ T cells, and reduce M2 macrophages in the tumor tissue and spleen. Another promising finding was that IBC alleviated the proportion of myeloid-derived suppressor cells (MDSCs) in the tumor tissue but had no change in the spleen. The study of pharmacological effects of IBC was carried out and suggested IBC restrained M2-like polarization of RAW 264.7 cells by inhibiting the expression of ARG1 and MRC1 and suppressed the expression of ARG1 and TGF-ß in bone marrow-derived MDSC. In summary, this research screened IBC as an antineoplastic agent, which could attenuate the growth of pancreatic cancer via activating the immune activity and inducing cell apoptosis. It might be a reference for the antitumor ability of IBC and the treatment of the tumor microenvironment in pancreatic cancer.

2.
Light Sci Appl ; 11(1): 40, 2022 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-35347105
3.
4.
Light Sci Appl ; 6(1): e16230, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30167199
5.
Light Sci Appl ; 5(1): e16021, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30167118
6.
Guang Pu Xue Yu Guang Pu Fen Xi ; 31(4): 1138-41, 2011 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-21714278

RESUMO

To meet the research requirement of Ne-like Ge X-ray laser, we designed and fabricated soft X-ray multilayer mirrors at 23.4 nm. New material combination Ti/Si has been chosen based on the material selecting rule, considering the optical characteristics and physicochemical characteristics. Then the period thickness (d), material ratio (gamma), and period number (N) of the multilayer were optimized and the reflectivity was calculated by software. The coating parameters were optimized through experiments and the Ti/Si multilayer mirrors at 23.4 nm were fabricated by magnetron sputtering coating machine. The mirrors were tested by X-ray diffractometer and soft X-ray reflectometer after fabrication. The test results of the Ti/Si multilayer were lambda0 = 23.2 nm and R = 25.8%. Compared with Mo/Si multiplayer, which is generally used in soft X-ray region, the reflectivity of Ti/Si multilayer increases 10% approximately, and FWHM narrows by 1.8 nm at 23.4 nm, indicating better optical performance.

7.
Guang Pu Xue Yu Guang Pu Fen Xi ; 29(5): 1371-4, 2009 May.
Artigo em Chinês | MEDLINE | ID: mdl-19650492

RESUMO

The spectral responsivity is one of the important parameters of detector. With the development of ultraviolet detect technique accurate measure for the spectral responsivity of ultraviolet detector becomes more and more important. A measure principle which is based on the direct comparison measuring method for relative spectral response measurement of the ultraviolet ICCD is introduced. Based on the scientific-grade spectrometer with ultraviolet responsivity, a measurement facility was built. The relative spectral responsivity curve of the ultraviolet ICCD was obtained. The curve indicates that the spectral-response of UV-ICCD is from 220 to 300 nm and the peak response is near 270 nm, which indicates that the UV-ICCD is solar blind. The analysis of the uncertainty shows that the most largest uncertainty of measurement for relative spectral responsivity of the UV-ICCD is 7.79% and meets the requirement.

8.
Guang Pu Xue Yu Guang Pu Fen Xi ; 25(3): 360-4, 2005 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-16013306

RESUMO

The soft X-ray and vacuum ultraviolet sources developed in CIOMP are presented. The wall-stabilized argon arc source with spectrum stability and repeatability of +/-0.3% is applied to the calibration of spectrum intensity distribution of the vacuum ultraviolet instruments as an absolute standard source. The Penning source, duobplasma source and hollow cathode source are able to produce atomic and ionic line spectra as a wavelength standard source, which covers a few nanometers to several tens nanometers with spectrum radiation stability and repeatability of +/-1.0%. In particular, the low debris laser produced plasma source with liquid aerosol spray target recently developed can emit stronger soft X-ray for soft X-ray lithography and metrology, which has a transfer efficiency as high as 0.75%/2pi x sr/2% bandwidth.


Assuntos
Espectrometria por Raios X/métodos , Espectrofotometria Ultravioleta/métodos , Raios Ultravioleta , Raios X , Alumínio/química , Argônio/química , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Lasers , Espectrometria por Raios X/instrumentação , Espectrofotometria Ultravioleta/instrumentação , Vácuo
9.
Guang Pu Xue Yu Guang Pu Fen Xi ; 24(1): 1-3, 2004 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-15768961

RESUMO

This paper presents a method to detect and measure spectrum intensity from a laser plasma soft X-ray source. A Channel Electron Multiplier (CEM) and a calibrated silicon photodiode were used as detectors in this method, the former is a nonstandard detector and the latter is a standard one. Charge-sensitive preamplifiers were used for measuring total charges generated by detectors, and a monochromator with high resolution was employed as the spectrometer. The formulae to calculate spectrum intensity from laser plasma soft X-ray source was given, based on the known grating efficiency of the monochromator, CEM's gain and responsivity of the silicon photodiode to photons.


Assuntos
Desenho de Equipamento , Lasers , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Análise Espectral/métodos , Tomografia Computadorizada por Raios X/métodos , Raios X , Processamento de Sinais Assistido por Computador/instrumentação , Silício/química
10.
Guang Pu Xue Yu Guang Pu Fen Xi ; 23(1): 101-3, 2003 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-12939982

RESUMO

This paper describes a debris-free laser plasma soft X-ray source with a gas target, which has high operating frequency and can produce strong soft X-ray radiation. The valve of this light source is drived by a piezoelectrical ceramic whose operating frequency is up to 400 Hz. In comparison with laser plasma soft X-ray sources using metal target, the light source is debris-free. And it has higher operating frequency than gas target soft X-ray sources whose nozzle is controlled by a solenoid valve. A channel electron multiplier (CEM) operating in analog mode is used to detect the soft X-ray generated by the laser plasma source, and the CEM's output is fed to to a charge-sensitive preamplifier for further amplification purpose. Output charges from the CEM are proportional to the amplitude of the preamplifier's output voltage. Spectra of CO2, Xe and Kr at 8-14 nm wavelength which can be used for soft X-ray projection lithography are measured. The spectrum for CO2 consists of separate spectral lines originate mainly from the transitions in Li-like and Be-like ions. The Xe spectrum originating mainly from 4d-5f, 4d-4f, 4d-6p and 4d-5p transitions in multiply charged xenon ions. The spectrum for Kr consists of separate spectral lines and continuous broad spectra originating mainly from the transitions in Cu-, Ni-, Co- and Fe-like ions.

11.
Zhongguo Zhong Xi Yi Jie He Za Zhi ; 22(8): 584-6, 2002 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-12572377

RESUMO

OBJECTIVE: To observe the effect of Yishen Jiedu Recipe (YSJDR) in retarding the course of chronic renal failure (CRF). METHODS: Forty-five patients were divided into two groups, the 22 patients in Group A were treated with low-protein diet and blood pressure controlling therapy only, while the 23 patients in Group B were treated with additional YSJDR. The time (month) for doubling serum creatinine (SCr) level was taken to evaluate the speed of CRF progression. RESULTS: In Group A, the time for SCr increased from 288.4 +/- 96.7 mumol/L to 586.3 +/- 251.3 mumol/L was 16.7 +/- 5.1 months, while in Group B the time for SCr increased from 291.2 +/- 101.2 mumol/L to 589.6 +/- 257.5 mumol/L was 28.2 +/- 8.7 months. Comparison between the two groups showed significant difference (P < 0.05). CONCLUSION: On the basis of low-protein diet and blood pressure controlling therapy, the additional treatment of YSJDR could markedly retard the progression speed of CRF.


Assuntos
Medicamentos de Ervas Chinesas/uso terapêutico , Falência Renal Crônica/tratamento farmacológico , Fitoterapia , Adulto , Creatinina/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...