Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nature ; 413(6858): 825-8, 2001 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-11677601

RESUMO

Synchrotrons produce continuous trains of closely spaced X-ray pulses. Application of such sources to the study of atomic-scale motion requires efficient modulation of these beams on timescales ranging from nanoseconds to femtoseconds. However, ultrafast X-ray modulators are not generally available. Here we report efficient subnanosecond coherent switching of synchrotron beams by using acoustic pulses in a crystal to modulate the anomalous low-loss transmission of X-ray pulses. The acoustic excitation transfers energy between two X-ray beams in a time shorter than the synchrotron pulse width of about 100 ps. Gigahertz modulation of the diffracted X-rays is also observed. We report different geometric arrangements, such as a switch based on the collision of two counter-propagating acoustic pulses: this doubles the X-ray modulation frequency, and also provides a means of observing a localized transient strain inside an opaque material. We expect that these techniques could be scaled to produce subpicosecond pulses, through laser-generated coherent optical phonon modulation of X-ray diffraction in crystals. Such ultrafast capabilities have been demonstrated thus far only in laser-generated X-ray sources, or through the use of X-ray streak cameras.

2.
Nucl Med Biol ; 23(5): 611-6, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8905825

RESUMO

The in vivo behavior of (-)-[11C]phenylephrine (PHEN) is compared with the structurally similar but monoamine oxidase (MAO)-resistant analog (-)-[11C]-m-hydroxyephedrine (HED), which is an established heart neuronal marker. The chiral synthesis of PHEN has been achieved by direct methylation of (-)-m-octopamine with either 11CH3I or CF3SO311CH3. These synthetic methods produced PHEN with a specific activity ranging from 500-1000 Ci/mmol, in a radiochemical yield of > 50% (EOS) and with an enantiomeric purity of 94-96%. Biodistribution studies indicate the initial uptake of PHEN in rat heart is approximately half that of HED. Following PHEN injection, radioactivity egresses from the rat heart rapidly, with 50% washout occurring from 5 to 60 min. HED washout over this interval was less than 20%. The heart neuronal selectivity determined by desipramine blockade of the amine neuronal transporter was 75-77% compared to 92-95% for HED. Ring-labeled (-)-[3H]phenylephrine gave tissue-to-blood concentration ratios and heart clearance times very similar to PHEN. Rats pretreated with the MAO A inhibitor clorgyline showed higher levels of activity in the heart at 15 and 60 min. Tandem PET studies with PHEN and HED in the closed-chest dog provided excellent heart images with both tracers.


Assuntos
Radioisótopos de Carbono , Coração/diagnóstico por imagem , Fenilefrina/farmacocinética , Animais , Clorgilina/farmacologia , Cães , Feminino , Coração/efeitos dos fármacos , Indicadores e Reagentes , Marcação por Isótopo/métodos , Miocárdio/metabolismo , Fenilefrina/síntese química , Ratos , Ratos Sprague-Dawley , Fatores de Tempo , Distribuição Tecidual , Tomografia Computadorizada de Emissão
3.
J Nucl Med ; 34(3): 440-7, 1993 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8441036

RESUMO

The utilization of image-derived input functions is becoming common in quantitative PET studies of the heart. Consequently, imaging protocols must be designed to sample both blood and tissue concentrations adequately. Most clinical imaging protocols consist of a series of short initial scans to measure the rapid change in blood and tissue tracer concentration levels, followed by scans of gradually increasing length. The number of initial short scans must be matched to the shape of the input function. In this paper, noise-free simulation studies were performed to evaluate the effect of temporal sampling on estimates of the parameters of a two-compartment kinetic model. In addition, the consequences of varying tracer infusion length and timing were studied. The kinetic model parameters' bias decreased when infusion times were lengthened or sampling rates increased. Our results indicated that tracer infusions of 30 sec were best suited for these studies. Two currently employed clinical imaging protocols were then optimized for use with this infusion scheme. Ten initial scans with durations of 10 sec, or twenty of 5 sec length produced unbiased estimates of kinetic model parameters that describe myocardial physiology. Noisy simulations with the equivalent of one million events confirmed these results.


Assuntos
Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão , Coração/fisiologia , Humanos , Tomografia Computadorizada de Emissão/métodos
4.
J Nucl Med ; 33(6): 1243-50, 1992 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1597746

RESUMO

The distortions inherent in PET images of the human heart due to finite image resolution and cardiac motion limit the capability to evaluate physiology quantitatively. A method based on a simple geometrical model of region of interest representations in physical space has been developed to minimize these distortions. In this paper, simulation studies have been performed to evaluate the noise characteristics of the method. This study demonstrates that unbiased estimates of kinetic model parameters which describe myocardial physiology can be measured with an accuracy of 7%-15% for scale-related parameters and 4%-16% for shape-related parameters of kinetic models in studies with the equivalent of 1 million events. Application of the techniques developed in this paper for the measurement of myocardial blood flow in eight dogs (14 independent flow states) shows a strong correlation with microsphere determined blood flow in the same animals (slope = 1.022, intercept = -0.18, r = 0.96).


Assuntos
Simulação por Computador , Coração/diagnóstico por imagem , Modelos Biológicos , Tomografia Computadorizada de Emissão/métodos , Animais , Circulação Coronária/fisiologia , Cães , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...