Biophys J ; 114(9): 2221-2230, 2018 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-29742415

RESUMO

Stroke is a leading cause of death globally and is caused by stenoses, abnormal narrowings of blood vessels. Recently, there has been an increased interest in shear-activated particle clusters for the treatment of stenosis, but there is a lack of literature investigating the impact of different stenosis geometries on particle margination. Margination refers to the movement of particles toward the blood vessel wall and is desirable for drug delivery. The current study investigated ten different geometries and their effects on margination. Microfluidic devices with a constricted area were fabricated to mimic a stenosed blood vessel with different extent of occlusion, constricted length, and eccentricity (gradualness of the constriction and expansion). Spherical fluorescent particles with a diameter of 2.11 µm were suspended in blood and tracked as they moved into, through, and out of the constricted area. A margination parameter, M, was used to quantify margination based on the particle distribution after velocity normalization. Experimental results suggested that a constriction leads to an enhanced margination, whereas an expansion is responsible for a decrease in margination. Further, margination was found to increase with increasing percent occlusion and constriction length, likely a result of higher shear rate and longer residence time, respectively. Margination decreases as the stenosis geometry becomes more gradual (eccentricity increases) with the exception of a sudden constriction/expansion geometry. The findings demonstrate the importance of geometric effects on margination and call for detailed numerical modeling and geometric characterization of the stenosed areas to fully understand the underlying physics.


Assuntos
Hemodinâmica , Modelos Biológicos , Animais , Bovinos , Constrição Patológica/fisiopatologia , Dispositivos Lab-On-A-Chip
2.
Biophys J ; 111(7): 1487-1495, 2016 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-27705771

RESUMO

Margination refers to the migration of particles toward blood vessel walls during blood flow. Understanding the mechanisms that lead to margination will aid in tailoring the attributes of drug-carrying particles for effective drug delivery. Most previous studies evaluated the margination propensity of these particles via an adhesion mechanism, i.e., by measuring the number of particles that adhered to the channel wall. Although particle adhesion and margination are related, adhesion also depends on other factors. In this study, we quantified the margination propensity of particles of varying diameters (0.53, 0.84, and 2.11 µm) and apparent wall shear rates (30, 61, and 121 s-1) by directly tracking fluorescent particles flowing through a microfluidic channel. The margination parameter, M, is defined as the total number of particles found within the cell-free layers normalized by the total number of particles that passed through the channel. In this study, an M-value of 0.2 indicated no margination, which was observed for all particle sizes in water. In the case of blood, larger particles were found to have higher M-values and thus marginated more effectively than smaller particles. The corresponding M-values at the device outlet were 0.203, 0.223, and 0.285 for 0.53-, 0.84-, and 2.11-µm particles, respectively. At the inlet, the M-values for all particle sizes in blood were <0.2, suggesting that non-fully-developed flow and constriction may lead to demargination. For particle velocities transverse to the flow direction (vy), all particle sizes showed a larger standard deviation of vy as well as a higher effective diffusivity when the particles were suspended in blood relative to water. These higher values are attributed to collisions between the blood cells and particles, further supporting recent simulation results. In terms of flow rates, for a given particle size, the higher the flow rate, the higher the M-value.


Assuntos
Hemorreologia , Microfluídica , Animais , Sangue/metabolismo , Bovinos , Corantes Fluorescentes , Dispositivos Lab-On-A-Chip , Modelos Biológicos , Tamanho da Partícula , Água/química , Água/metabolismo