2.
Anaesthesia ; 55(7): 654-8, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10919420

RESUMO

In Study A, the incidence of arterial oxygen desaturation was studied using pulse oximetry (SaO2) in 100 sedated and 100 nonsedated patients breathing room air who underwent diagnostic upper gastrointestinal endoscopy. Hypoxia (SaO2 92% or less of at least 15 s duration) occurred in 17% and 6% of sedated patients and nonsedated patients, respectively (p < 0.03). Mild desaturation (SaO2 94% or less and less than 15 s duration) occurred in 47% of sedated patients compared with 12% of nonsedated patients (p < 0.001). In Study B, the effects of supplementary oxygen therapy and the effects of different pre-oxygenation times on arterial oxygen saturation (SaO2) in sedated patients were studied using pulse oximetry. One hundred and twenty patients who underwent diagnostic upper gastrointestinal endoscopy with intravenous sedation were studied. Patients were randomly allocated to one of four groups: Group A (n = 30) received no supplementary oxygen while Groups B-D received supplementary oxygen at 4 1 x min(-1) via nasal cannulae. The pre-oxygenation time in Group B (n = 30) was zero minutes, Group C (n = 30) was 2 min and Group D (n = 30) was 5 min before sedation and introduction of the endoscope. Hypoxia occurred in seven of the 30 patients in Group A and none in groups B, C and D (p < 0.001). We conclude that desaturation and hypoxia is common in patients undergoing upper gastrointestinal endoscopy with and without sedation. Sedation significantly increases the incidence of desaturation and hypoxia. Supplementary nasal oxygen at 4 1 x min(-1) in sedated patients abolishes desaturation and hypoxia. Pre-oxygenation confers no additional benefit.


Assuntos
Sedação Consciente , Endoscopia Gastrointestinal/efeitos adversos , Hipóxia/etiologia , Hipóxia/prevenção & controle , Oxigenoterapia/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria , Satisfação do Paciente , Método Simples-Cego
3.
Med J Malaysia ; 54(1): 72-8, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10972008

RESUMO

The Malaysian Society of Anaesthesiologists published a document entitled "Recommendations for Standards of Monitoring during Anaesthesia and Recovery" in 1993. This paper examines the results of two surveys, carried out in 1995 and 1996 respectively; to determine compliance with published Monitoring Standards in Malaysian public and private hospitals. In the private sector, compliance with the recommended standards during anaesthesia varied greatly. Of the 28 government hospitals surveyed in 1996, compliance with monitoring standards during anaesthesia was almost 100%. Standards in recovery areas were less than ideal. The majority of anaesthesiologists thought that the current recommended standards were adequate.


Assuntos
Anestesia/normas , Fidelidade a Diretrizes , Monitorização Fisiológica/normas , Anestesia/efeitos adversos , Hospitais , Humanos , Malásia , Segurança
SELEÇÃO DE REFERÊNCIAS